Shop
Non-contact liquid level measurement
High frequency 80GHz, more focus
Accuracy ±2 mm(liquid)
Measuring range up to 30m
Easy Setup via Bluetooth<
Small emitting angle ±3.5°
4-20 mA+HART+RS485 output
G1,5 connection
IP67 protection
Ideal for non-contact liquid level measurement in simple applications. It is especially suitable for open channel applications. It can also be used in some liquid tanks and containers. With Bluetooth feature, it allows level reading and adjustment without approaching the tank or hazardous area.
| Measuring Range | Output | Protection | Accuracy | Datasheet |
|---|---|---|---|---|
| Up to 30 meters (liquid) | 4-20 mA+HART+RS485 | IP67 | ±2 mm |
Non-contact liquid and solid level measurement
High frequency 80GHz, more focus
Accuracy ±2 mm(liquid), ±5 mm(solid)
Measuring range up to 30m
Small emitting angle ±3.5°
4-20 mA+HART+RS485 output
G2 connection
Exproof
IP67 protection
Ideal for for continuous level measurement in liquid, simple solid and open water applications. Exproof and suitable for use in explosive environments.
| Measuring Range | Output | Protection | Accuracy | Datasheet |
|---|---|---|---|---|
| Up to 30 meters (liquid and solid) | 4-20 mA+HART+RS485 | IP67 | ±2 mm (liquid) ±5 mm (solid) |
Temassız sıvı seviyesi ölçümü
70 metreye kadar ölçüm
5 dijit LCM gösterge
4-20 mA ve HART çıkışı
±3mm’ye kadar doğruluk
Alüminyum gövde
IP67 koruma sınıfı
Dayanıklı gövde; toz birikmelerini önleyen conta tasarımı
| Ölçüm Aralığı | Çıkış | Koruma | Doğruluk | Datasheet |
|---|---|---|---|---|
| 70 metreye kadar | 4-20 mA, HART | IP67 | ±3 mm’ye kadar |
Algılanan minimum malzeme yoğunluğu; katı:≥0.07g/cm³ sıvı:≥0.7g/cm³
PNP çıkış
100 mm sus 316L çatal
SUS 304 gövde malzemesi
LED durum göstergeleri
IP65 (DIN43650 soketli) koruma sınıfı
Dayanıklı gövde; toz birikmelerini önleyen conta tasarımı
| Algılanan minimum Malzeme Yoğunluğu | Çıkış | Bağlantı | Koruma | Çalışma Sıcaklığı | Datasheet |
|---|---|---|---|---|---|
| Katı:≥0.07g/cm³ Sıvı:≥0.7g/cm³ | PNP | 1″PF (G) | IP65 | -40…+100°C |
Min. material density sensed; 0.04g/cm³
2xSPDT relay output
SUS304/SUS316/SUS316L rod from 160mm to 6000mm
Aluminum housing material
LED status indicator
IP65 protection class
| Min. material density sensed | Output | Connection | Protection | Operating Temp. | Datasheet |
|---|---|---|---|---|---|
| ≥0.04 g/cm³ | 2 x SPDT Relay | 1″PT | IP65 | -40…+150°C |
10-28VDC supply voltage
NPN, PNP open collector output to energize relay or PLC
Housing material of PC, PES, SUS304, SUS316 for applicable in water, oil, liquid solution, liquor, alcohol, organic solvent…etc.
Over-current and reverse polarity protected
LED status indicator
IP67 protection class
The optical liquid level switch uses the principle of total reflection in a prism. When the sensor is surrounded by air, the angle of incidence is greater than the critical angle and thus total reflection occurs. Totally reflected light will be transmitted to the receiver. Conversely, when the sensor is surrounded by liquid, due to the refractive index of the liquid and the sensor tip material, almost all light will penetrate the front of the sensor. The receiver can detect and determine a light reflected or penetrated state, and determines the circuit output
| Supply Voltage | Output | Connection | Protection | Operating Temp. | Datasheet |
|---|---|---|---|---|---|
| 10~28 Vdc | NPN or PNP Open Collector | PT, PF, NPT | IP67 | -10…+125°C |
12-30VDC supply voltage
NPN or PNP output
Suitable for Liquid, viscous medium, powder, granular medium
Probe material PEEK surface roughness Ra <0.8 is with good wear resistance
LED status indicator
Compact and durable structure
NEPSI ex-proof certificate
IP67 protection
The sensor uses a frequency sweep method which emits an electrical signal at the sensing terminal to detect materials. Different mediums with different characteristics will generate different resonances, which will determine whether the sensor is covered by any materials, causing the switch output signal to light up. Suitable for single-point detection and protection of liquids, viscous mediums, powders, and granular mediums in tanks or pipelines.
| Supply Voltage | Output | Connection | Protection | Operating Temp. | Datasheet |
|---|---|---|---|---|---|
| 12~30 Vdc | NPN or PNP | Standard type: 1/2”G Rear mounting type: 3/4”G |
IP67 | Normal: -40…+80°C Ex-proof: -10…+70°C |
Algılanan minimum malzeme yoğunluğu: ≥0.07g/cm³
Temassız elektronik switch veya NPN/PNP çıkış
1″ veya 3/4″ PF bağlantı
40 mm çatal uzunluğu
SUS 304 gövde malzemesi
LED durum göstergeleri
IP65 (DIN43650 soketli) veya IP67(M12 soketli) koruma sınıf
Dayanıklı gövde; toz birikmelerini önleyen conta tasarımı
| Algılanan minimum Malzeme Yoğunluğu | Çıkış | Bağlantı | Koruma | Çalışma Sıcaklığı | Datasheet |
|---|---|---|---|---|---|
| ≥0.07g/cm³ | Temassız Elektronik Switch veya PNP / NPN | 1″PF veya 3/4″PF | IP65 veya IP67 | -40…+100°C |
Electronic display counter for measuring movement and angles
6 digit LCD display, programming with 3 different keys
Integrated battery with a lifetime of at least 4 years
400 rpm maximum speed
IP54 protection class (Optional IP65)
Electronic gauge with precision and full hollow shaft for measuring movement and angles; body made of impact-resistant special plastic and stainless steel; easily replaceable 4 year integrated battery
| Indicator Number of Digits | Hollow Shaft Diameter | Protection | Measure After 1 Rev. | Maximum Speed | Datasheet |
|---|---|---|---|---|---|
| 6 digit LCD | 14 or 2 mm | IP 54 |
The desired value from -99999 to +99999
|
400 RPM |
4 meters detection distance
32 ms fast response time
Audible warning system
L-type frame assembly
IP54 protection class
Infrared light curtains for door safety detection; L type bracket mounting; 36 photodiodes; audible warning system
| Detection Distance | Response Time | Protection | Datasheet |
|---|---|---|---|
| 4 meters | 32 ms | IP54 |
Hall effect technology
5V or 10V push-pull output
LED status indicator
Reverse polarity and short-circuit protection
With the Hall effect technology, it detects the movement in the gears and gives a push-pull output signal.
| Operating Voltage | Operating Distance | Output | Datasheet |
|---|---|---|---|
| 8…33VDC | 4,2 mm max. |
5V or 10V Push-Pull
|
Linear Measurement
Rotary Measurement
Inclination/ Tilt Measurement
Laser Distance Sensors
Pressure Measurement
Level Measurement
Temperature Measurement
Liquid Flow Measurement
Proximity Sensors
Joysticks
Dro, Display and Counters
Elevator Light Curtains
Speed and Motion Measurement
Counting Sensors
Seismic / Earthquake Sensors
Mechanical Plunger Switches
Accelerometers
Faucet Sensors
Seam Detector Sensors
Encoder Signal Conditioner and Optical Isolator
Couplings
Cable and Connectors


