Complete metal design
Applications up to 400°C ambient temperature
IP50 socket connection protection class
IP7 sensor protection class
Maximum 2000 bar melt pressure
0-10V or 4-20 mA analog output

Melt temperature sensor with all metal design, up to 400 °C

Measuring Range Output Protection Maximum Melt Pressure Datasheet
 0 … 400 °C
0-10V or 4-20 mA Plug connection (IP50), Sensor (IP67) 2000 bar

Pressure and temperature measurement with a single sensor
Completely welded thin-film steel diaphragm structure that does not require o-ring
Pressure measuring range options from 0…6 bar to 0…1000 bar (optional others)
-40 … +150°C temperature measurement (optional others)
4-20mA, 0-10V, 0.5-4.5V Ratiometric, PT100, PT1000 output options
G1/4, G1/2, NPT1/4, NPT1/2, M14x1 process connection options
High accuracy and stability

Measurement of both pressure and temperature via a single sensor; Fully welded Thin-film steel diaphragm structure that does not require O-rings; high sensitivity; EMC and reverse polarization protection; wide range of analog output and mechanical connection options

Measuring Range Output Mechanical Connection Protection Datasheet
Temperature: -40ºC … +150ºC (opt. others)
Pressure: 6… 1000 bar (opt. others)
 4-20mA, 0-10V, 0.5-4.5V Ratiometric, RTD G1/4, G1/2, NPT1/4, NPT1/2, M14x1 vb.  IP65 or IP67

Pressure and temperature measurement with a single sensor
Completely welded thin-film steel diaphragm structure that does not require o-ring
Pressure measuring range options from 0…10 bar to 0…2000 bar (optional others)
-40 … +150°C temperature measurement (optional others)
4-20mA, 0-10V, 0.5-4.5V Ratiometric, PT100, PT1000 output options
High accuracy and stability

Measurement of both pressure and temperature via a single sensor; Fully welded Thin-film steel diaphragm structure that does not require O-rings; high sensitivity; EMC and reverse polarization protection; wide range of analog output and mechanical connection options

Measuring Range Output Mechanical Connection Protection Datasheet
Temperature: -40ºC … +150ºC (opt.others)
Pressure: 10… 2000 bar (opt.others)
4-20mA, 0-10V, 0.5-4.5V Ratiometric, RTD G1/4 IP65 or IP67

Exproof thermostat/ambistat
Measuring range from 30 °C … + 30 °C to 0 °C … + 60 °C
±0.5% FS repeatability
Switch output
Compact design
IP 65 protection class

Thermostat/ambistat; stainless steel body; high repeatability; long life with high stability that does not change in the long term; EX certificate for explosive atmosphere

Measuring Range Output Protection Repeatability Datasheet
-30°C … +30 °C to 0°C … + 60°C Switch
IP65
±%0.5 FS

Thermostat for ship industry
+20 °C … +110 °C to +40 °C … +300 °C Measuring range
±0.5% FS repeatability
Switch output
Compact design
IP 65 protection class

Thermostat for ship industry; stainless steel body; high repeatability; long life with unchanging high stability in the long term

Measuring Range Output Protection Repeatability Datasheet
 +20°C … +110 °C to +40°C … + 300°C Switch
IP65
±%0.5 FS

Freezing thermostat for refrigeration sector
-5°C … + 15°C measuring range
±0.5% FS repeatability
Switch output
Compact design
IP 54 protection class

Freezing Thermostat Froststat; frost-resistant housing; high repeatability; Long life with unchanging high stability in the long term

Measuring Range Output Protection Repetability Datasheet
-5°C … +15 °C Switch
IP54
±%0.5 FS

Electromangnetic working principle
±0,2% accuracy
Analog or digital output options
220VAC or 24VDC power supply
IP65 protection class
Robust housing

Excellent flow mesurement accuracy, can measure duplex flow, electromagnetic debimeter with 4-20mA and other outputs

Measurement Value Output Accuracy Protection Datasheet
3 m/s  4-20 mA (pulse, RS-232, RS-485, HART) ±0,2% IP 65

Electromagnetic working principle
15-1200 mm variable diameter measurement
±0.2% or ± 0.5% accuracy
Analogue or digital output options
220VAC or 24VDC supply
IP65 protection class
Robust housing

Electromagnetic flowmeter capable of measuring up to 7000 m³ / h and 4-20mA and other outputs

Measurement Range Output Accuracy Protection  Datasheet
Up to 7000 m³/h  4-20 mA (standard), Pulse, RS485, HART, Profibus-PA ±%0,2 or ±%0,5 IP 65

Electromagnetic working principle
15-1200 mm variable diameter measurement
±0.2% or ± 0.5% accuracy
Analogue or digital output options
220VAC or 24VDC supply
IP65 or IP68 protection class
Robust housing

Electromagnetic flowmeter capable of measuring up to 7000 m³ / h and 4-20mA and other outputs

Measurement Range Output Accuracy Protection  Datasheet
Up to 7000 m³/h  4-20 mA (standard), Pulse, RS485, HART, Profibus-PA ±%0,2 or ±%0,5 IP 65, IP 68

Ultrasonic working principle
±0,5% accuracy
Analog or digital output options
220VAC or 24VDC power supply
IP65 protection class
Robust housing

Ultrasonic flow meter with perfect measurement precision and flexible display

Max Flow Velocity Output Accuracy Protection Datasheet
64 m/s  4-20 mA, MODBUS, M-BUS, FUJI ±%0,5 IP 65

Ultrasonic working principle
±1% accuracy
RS-232 output
Rechargeable battery
IP65 protection class
Robust housing

Handheld ultrasonic flow meter with RS-232 output, with high accuracy, stability, easy operation and carrying

Max Flow Velocity Output Accuracy Protection Datasheet
64 m/s  RS-232 ±%1 IP 65

Detection of ferrous metal objects by inductive principle
Ø8, Ø12, Ø18 or Ø30 mm models
DC 2-wire or 3-wire
Non-flush
LED status indicator
IP67 protection

Non-contact measurement of ferrous metal objects by inductive principle; DC 2-wire or 3-wire; various body diameter options; long service life

 Body Diameter (mm) Sensing Distance Setting Distance Output Type Mounting Type Protection Datasheet
Ø8
Ø12
Ø18 
Ø30 
Ø8:0 … 2 mm
Ø12:0 … 4 mm
Ø18:0 … 8 mm
Ø30:0 … 15 mm
Ø8:0 … 1.4 mm
Ø12:0 … 2.8 mm
Ø18:0 … 5.6 mm
Ø30:0 … 11 mm
2-wire
3-wire NPN
3-wire PNP
Non-Flush IP67