SD204 Optical Level Control Sensor || FineTek
10-28VDC supply voltage
NPN, PNP open collector output to energize relay or PLC
Housing material of PC, PES, SUS304, SUS316 for applicable in water, oil, liquid solution, liquor, alcohol, organic solvent…etc.
Over-current and reverse polarity protected
LED status indicator
IP67 protection class
The optical liquid level switch uses the principle of total reflection in a prism. When the sensor is surrounded by air, the angle of incidence is greater than the critical angle and thus total reflection occurs. Totally reflected light will be transmitted to the receiver. Conversely, when the sensor is surrounded by liquid, due to the refractive index of the liquid and the sensor tip material, almost all light will penetrate the front of the sensor. The receiver can detect and determine a light reflected or penetrated state, and determines the circuit output
Supply Voltage | Output | Connection | Protection | Operating Temp. | Datasheet |
---|---|---|---|---|---|
10~28 Vdc | NPN or PNP Open Collector | PT, PF, NPT | IP67 | -10…+125°C | ![]() |
- 10-28VDC supply voltage
- NPN, PNP open collector output to energize relay or PLC
- Housing material of PC, PES, SUS304, SUS316 for applicable in water, oil, liquid solution, liquor, alcohol, organic solvent…etc.
- Over-current and reverse polarity protected
- LED status indicator
- Compact and robust
- IP67 protection class
Brand |
Finetek |
---|---|
Supply Voltage |
10~28 Vdc |
Load current |
≤100 mA |
Current consumption |
<15 mA |
Output mode |
NPN / PNP |
Output function |
NO / NC |
Electrical protection |
reverse polarity protection, short circuit protection |
Ambient temperature |
-10~+80°C |
Operating temperature |
-10~125°C |
Operating pressure |
<40 kg / cm^2 |
Protection Class |
IP67 |
Indicator light |
Red LED |
Housing material |
SUS304 / SUS316 |
Tip material |
PES |
Installation torque |
100 kgf-cm |
Thread options |
PT /PF / NPT |
Pharmaceutical systems
Industrial compressors
Food and beverage systems
Air conditioning systems
Hydraulic reservoirs
Machine tools
Processing and packaging equipment
Heavy duty automotive
Liquid holding tanks
Sumps
DATASHEET
|
|
---|---|
Benzer Ürünler
1.4462 (duplex), 316L or titanium body High corrosion resistance, suitable for use in salt water Different level measurements from 4 meters to 100 meters 4-20mA or 0-10 VDC analog output options ± 0.3% accuracy IP68 protection class
Standard diaphragm; submersible level transmitters; durable for harsh conditions; dublex, 316L or titanium body; high precision; EMC and reverse polarity protection; Suitable for applications such as seawater, saltwater, grey water, waste water etc.
Measuring Range | Membrane | O-Ring | Output | Protection | Accuracy | Datasheet |
---|---|---|---|---|---|---|
Between 0-400 mbar and 0-25 bars From 4 meters to 100 meters depth | Ceramic | NBR | 4-20 mA or 0-10 VDC | IP68 | %0,3 | ![]() |
Suitable for mineral oils Alarm delay time between 0-40 seconds can be selected at the ordering stage 40 Bar pressure resistance Sink (NPN) or source (PNP) output type High accuracy and stability IP67 protection class
Suitable for level measurement in mineral oils, sink (NPN) or source (PNP) output, selectable alarm delay time between 0-40 seconds0.5~1.0KG-cm torque 1 RPM speed SPDT switch output 220VAC or 24VDC supply IP65 protection class Pedal type options
MSS series rotary paddle switches are used for level control in silos and tanks where materials with solid particles are stored. Full and empty signals can be received by performing level control in many demanding applications with different pedal varieties in a safe manner. They can be connected horizontally and vertically.
Torque | Connection Type | Output | Protection | Datasheet |
---|---|---|---|---|
0.5~1.0KG-cm | 1-1/2” PT | SPDT Switch | IP65 | ![]() |
Maximum 0.8 bar working pressure 3 different sensitivity settings Relay output 220VAC or 24VDC powered version IP65 protection class Robust housing
The TLS 110 and TLS 210 series motor level sensors are commonly used to determine the lower and upper positions of the level in areas such as Silo, Warehouse, etc., or intermediate values if desired
Working Pressure | Connection Type | Output | Protection | Datasheet |
---|---|---|---|---|
Maximum 0.8 Bar | G1½" and G2½" | Relay(microswitch) | IP65 | ![]() |
Shaft with length of 15, 30, 50 cm Aluminium housing Switch output 220VAC or 24VDC supply IP65 protection class Exproof, Atex marking
Atex certified, suitable for use in explosive environments, ex-proof propeller level control sensor for powder or granulesOperating Temperature | Body | Output | Protection | Datasheet |
---|---|---|---|---|
-10ºC ... +60ºC | Aluminium | Switch | IP65 | ![]() |
Non-contact measurement with ultrasonic principle Different measuring options up to 6 meters Acid-proof option 4-20mA, 0-10V, 0-20 mA analog output options CANopen, RS485, RS232 serial communication options 2 x PNP open collector outputs IP67 protection class
Non-contact, level and volume measurement of liquid and solid materials in open and closed tanks; small structure; 316L, delrin or teflon housing options; acid-proof option
Measuring Range | Output | Taper Angle | Accuracy | Protection | Datasheet |
---|---|---|---|---|---|
Measuring options up to 6 meters | 4-20 mA, 0-20 mA, 0-10V, CANopen, RS-232, RS-485, 2xPNP Open Collector | 10°, 12°, 30° | %0,2 FS | IP67 | ![]() |