SL-SL.ATEX Exproof Level Switch with Propeller || Fiama ||
Shaft with length of 15, 30, 50 cm
Aluminium housing
Switch output
220VAC or 24VDC supply
IP65 protection class
Exproof, Atex marking
Atex certified, suitable for use in explosive environments, ex-proof propeller level control sensor for powder or granules
| Operating Temperature | Body | Output | Protection | Datasheet |
|---|---|---|---|---|
| -10ºC … +60ºC | Aluminium | Switch | IP65 |
- Aluminium body
- Protecion degree IP65
- The steel shaft is mounted on hermetic seal ball bearings
- Plastic propeller (standard), aluminium or steel
- Threaded hub 1”1/2 inch gas
- Shaft with propeller is 15, 30, 50 cm long: the part that works inside the tank.
| Brand |
Fiama |
|---|---|
| Body Material |
Aluminum |
| Shaft Material |
Plastic |
| Protection Class |
IP65 |
| Electrical Contacts |
4A 250Vac – 2A 250Vdc |
| Operating Temperature |
-10°…+60° C |
| Absorbtion |
3 VA |
| Supply Voltage |
24 – 115 – 230 Vca ±10% 50/60 Hz – 24 Vdc ±10% |
| Shaft Length |
15 – 30 – 50 cm |
| Electromagnetic Compatibility |
2014/30/UE |
| NV-MUNO 0496 ATEX 07/3316 Marking |
II1/2 D Ex ta IIIC T95°C IP65 -15°C<Ta<+60°C |
| For 24VDC/S marking |
II1/2 D Ex ta IIIC T100°C IP65 -15°C<Ta<+60°C |
SL-SL.ATEX series vane level control sensors are used for level control in warehouses containing powder or granular materials. ATEX type (exproof) is used where a potentially explosive atmosphere may be present.
Benzer Ürünler
1.4462 (duplex), 316L or titanium body High corrosion resistance, suitable for use in salt water Different level measurements from 4 meters to 100 meters 4-20mA or 0-10 VDC analog output options ± 0.2% accuracy IP68 protection class
Standard diaphragm; submersible level transmitters; durable for harsh conditions; dublex, 316L or titanium body; high precision; EMC and reverse polarity protection; Suitable for applications such as seawater, saltwater, grey water, waste water etc.| Measuring Range | Membrane | O-Ring | Output | Protection | Accuracy | Datasheet |
|---|---|---|---|---|---|---|
|
Between 0-400 mbar and 0-25 bars
From 4 meters to 100 meters depth |
Ceramic | NBR | 4-20 mA or 0-10 VDC | IP68 | %0,2 |
Suitable for water and water based liq Alarm delay time between 0-40 seconds can be selected at the ordering stage 40 Bar pressure resistance Sink (NPN) or source (PNP) output type High accuracy and stability IP67 protection class
Suitable for level measurement in water and water based liquids, sink (NPN) or source (PNP) output, selectable alarm delay time between 0-40 secondsSpecial design for textile sector Piezoresistive working principle 316L stainless steel housing Different models between 100 mBar and 600 mBar Analog 4-20mA / 0-10V and so on different outputs ±0.3% F.S accuracy IP65 protection class Compact construction
Special design for textile sector; stainless steel body; air isolated mounting; high sensitivity; EMC and reverse polarization protected; small and compact design
| Measuring Range | Output | Protection | Accuracy | Body Diameter | Datasheet |
|---|---|---|---|---|---|
| Different models from 0...100mbar to 0...600mbar | 4-20 mA, 0-10 VDC, 0-20 mA, 1-6 VDC, 0-5 VDC, Ratiometric etc. | IP65 | ±%0,3 F.S | 23mm |
Non-contact liquid level measurement High frequency 80GHz, more focus Accuracy ±2 mm(liquid) Measuring range up to 30m Easy Setup via Bluetooth Small emitting angle ±3.5° 4-20mA + RS485 output G1,5 connection IP67 protection
Ideal for non-contact liquid level measurement in simple applications. It is especially suitable for open channel applications. It can also be used in some liquid tanks and containers.With Bluetooth feature, it allows level reading and adjustment without approaching the tank or hazardous area.| Measuring Range | Output | Protection | Accuracy | Datasheet |
|---|---|---|---|---|
| Up to 30 meters (liquid) | 4-20 mA + RS485 | IP67 | ±2 mm |
10-28VDC supply voltage NPN, PNP open collector output to energize relay or PLC Housing material of PC, PES, SUS304, SUS316 for applicable in water, oil, liquid solution, liquor, alcohol, organic solvent...etc. Over-current and reverse polarity protected LED status indicator IP67 protection class
The optical liquid level switch uses the principle of total reflection in a prism. When the sensor is surrounded by air, the angle of incidence is greater than the critical angle and thus total reflection occurs. Totally reflected light will be transmitted to the receiver. Conversely, when the sensor is surrounded by liquid, due to the refractive index of the liquid and the sensor tip material, almost all light will penetrate the front of the sensor. The receiver can detect and determine a light reflected or penetrated state, and determines the circuit output| Supply Voltage | Output | Connection | Protection | Operating Temp. | Datasheet |
|---|---|---|---|---|---|
| 10~28 Vdc | NPN or PNP Open Collector | PT, PF, NPT | IP67 | -10...+125°C |
Linear Measurement
Rotary Measurement
Inclination/ Tilt Measurement
Laser Distance Sensors
Pressure Measurement
Level Measurement
Temperature Measurement
Liquid Flow Measurement
Proximity Sensors
Joysticks
Dro, Display and Counters
Elevator Light Curtains
Speed and Motion Measurement
Counting Sensors
Seismic / Earthquake Sensors
Mechanical Plunger Switches
Accelerometers
Faucet Sensors
Seam Detector Sensors
Encoder Signal Conditioner and Optical Isolator
Couplings
Cable and Connectors




