ARD 110 Radar Level Transmitter || Atek
Non-contact liquid level measurement
High frequency 80GHz, more focus
Accuracy ±2 mm(liquid)
Measuring range up to 30m
Easy Setup via Bluetooth
Small emitting angle ±3.5°
4-20mA + RS485 output
G1,5 connection
IP67 protection
Ideal for non-contact liquid level measurement in simple applications. It is especially suitable for open channel applications. It can also be used in some liquid tanks and containers.With Bluetooth feature, it allows level reading and adjustment without approaching the tank or hazardous area.
Measuring Range | Output | Protection | Accuracy | Datasheet |
---|---|---|---|---|
Up to 30 meters (liquid) | 4-20 mA + RS485 | IP67 | ±2 mm | ![]() |
- Non-contact liquid level measurement
- High frequency 80GHz, more focus
- Accuracy ±2 mm(liquid)
- Measuring range up to 30m
- Easy Setup via Bluetooth
- Small emitting angle ±3.5°
- 4-20mA + RS485 output
- G1,5 thread connection
- IP67 protection
Brand |
Atek |
---|---|
Product Type |
FMCW Radar Level Transmitter |
Application |
Open channel water measurement |
Frequency |
77Ghz – 81Ghz |
Measurement Range |
Liquid: 10m, 20m, 30m |
Accuracy |
±2mm |
Beam Angle |
±3.5° |
Material |
PP (polypropylene) |
Process Connection |
G1,5 Thread |
Process Temperature |
-20…70°C |
Process Pressure |
Normal atmospheric pressure |
Signal output |
4-20 mA + RS485 |
Power |
Two-wire DC 24V (22V~30V) |
Protection |
IP67 |
ARD 110 is suitable for use in open areas, measuring streams, rivers, lakes and dam levels, in water channels, wastewater and clean water facilities. It can also be used in some liquid tanks and containers.
Benzer Ürünler
Suitable for mineral oils Alarm delay time between 0-40 seconds can be selected at the ordering stage 40 Bar pressure resistance Sink (NPN) or source (PNP) output type High accuracy and stability IP67 protection class
Suitable for level measurement in mineral oils, sink (NPN) or source (PNP) output, selectable alarm delay time between 0-40 seconds0.5~1.0KG-cm torque 1 RPM speed SPDT switch output 220VAC or 24VDC supply IP65 protection class Pedal type options
MSS series rotary paddle switches are used for level control in silos and tanks where materials with solid particles are stored. Full and empty signals can be received by performing level control in many demanding applications with different pedal varieties in a safe manner. They can be connected horizontally and vertically.
Torque | Connection Type | Output | Protection | Datasheet |
---|---|---|---|---|
0.5~1.0KG-cm | 1-1/2” PT | SPDT Switch | IP65 | ![]() |
Shaft with length of 15, 30, 50 cm Aluminium housing Switch output 220VAC or 24VDC supply IP65 protection class Exproof, Atex marking
Atex certified, suitable for use in explosive environments, ex-proof propeller level control sensor for powder or granulesOperating Temperature | Body | Output | Protection | Datasheet |
---|---|---|---|---|
-10ºC ... +60ºC | Aluminium | Switch | IP65 | ![]() |
Ultrasonic working principle 0.5 - 9 meters measuring distance 4-20mA, 0-10V, 0-20 mA analog output options available CANopen, RS485, RS232 serial communication options IP65 or IP67 protection class Robust housing
Non-contact, level and volume measurement of liquid and solid materials in open and closed tanks, measuring range can be calibrated from the menuMeasuring Range | Output | Taper Angle | Accuracy | Protection | Datasheet |
---|---|---|---|---|---|
0.5 - 9 meters | 4-20 mA, 0-20 mA, 0-10V, CANopen, RS-232, RS-485, 2xPNP Open Collector | 30° | %0,2 FS | IP65 or IP67 | ![]() |
10-28VDC supply voltage NPN, PNP open collector output to energize relay or PLC Housing material of PC, PES, SUS304, SUS316 for applicable in water, oil, liquid solution, liquor, alcohol, organic solvent...etc. Over-current and reverse polarity protected LED status indicator IP67 protection class
The optical liquid level switch uses the principle of total reflection in a prism. When the sensor is surrounded by air, the angle of incidence is greater than the critical angle and thus total reflection occurs. Totally reflected light will be transmitted to the receiver. Conversely, when the sensor is surrounded by liquid, due to the refractive index of the liquid and the sensor tip material, almost all light will penetrate the front of the sensor. The receiver can detect and determine a light reflected or penetrated state, and determines the circuit outputSupply Voltage | Output | Connection | Protection | Operating Temp. | Datasheet |
---|---|---|---|---|---|
10~28 Vdc | NPN or PNP Open Collector | PT, PF, NPT | IP67 | -10...+125°C | ![]() |