MPTS 112 Melt Pressure Sensor With Rigid Body || ATEK || Made in Türkiye
Rigid body system
0-35 to 0-2000 bar / 0-500 to 0-30000 psi
Better than ±0.5% accuracy
4-20mA, 0-10 VDC or 3,33 mV/V output
Applications with process temperature of up to 350℃
Pressure and temperature measurement of hot fluids; Precise and durable measurement with mercury; titanium nitride coated rigid body
| Measuring Range | Body Structure | Output | Max. Temp. | Accuracy | Datasheet |
|---|---|---|---|---|---|
| 0…35 to 0…2000 bar kadar | Rigid Body | 4-20 mA, 0-10V, 3.33mV/V | 350°C | %0,5 FS |
- Rigid body system
- Better than ±0.5% accuracy
- 4 – 20mA, 0 – 10V or 3.33mV/V output
- 0-35 to 0-2000 bar / 0-500 to 0-30000 psi
- Internal 80% shunt calibration
- Standard Inconel diaphragm
- Optional auto-zero function
- Applications with process temperature of up to 350℃
- Maximum Torque:30Nm (22lbf ft)
- Optional safe relay function
| Brand |
Atek |
|---|---|
| Pressure Range |
0~35 to 2000bar (0~500 to 0~30000psi) |
| Measurement principle |
4-arm bonded foil strain gage Wheatstone bridge |
| Supply Voltage |
4-20 mA and 0-10V output models: 24VDC (recommended), 9…36 VDC |
| Output Signal |
4-20 mA |
| Max. diaphragm temp. |
350°C |
| Maximum Overload Pressure Rating |
1.5 x FS(<1000bar) |
| Pressure Units |
PSI, Bar, MPa or Kg/cm² |
| Accuracy |
± % 0,5 FS |
| Repeatability |
± % 0,2 FS |
| Internal Shunt Calibration |
% 80FSO ±%1 FSO |
| Temperature sensor |
No |
| Electrical Connection |
6PIN,7PIN, 8PIN |
| Max Torque |
30Nm |
| Process Connection |
1/2-20 UNF (45° conical seal) |
| Body |
Titanium Nitride |
| Diaphgram Material |
Inconel |
MPTS series melt pressure sensors are used to measure the pressure and temperature of hot fluids in the plastics, rubber, food, etc. sectors.
Benzer Ürünler
Ceramic diaphragm Stainless steel body Options from 0 ... 1 bar to 0 ... 400 bar ±0.5% FS sensitivity Different analog output options IP65, IP67 or IP68 protection class Economical and convenient solution Datashee
Pressure transmitter with ceramic diaphragm; economical and durable solution; relative or absolute measurement option
| Measuring Range | Output | Protection | Accuracy | Datasheet |
|---|---|---|---|---|
| 0 ... 1 to 0 ... 400 bar | 4-20 mA, 0-10 VDC, 0.5-4.5 VDC ratiometric, 0-5 VDC, 1-6 VDC | IP65, IP67, IP68 | ±%0.5 FS |
Thin-film steel diaphragm structure 26 mm diameter stainless steel housing Different options up to 2000 Bar Analog 4-20mA / 0-10V etc. outputs ±%0,5 F.S accuracy Compact design
Fully welded Thin-film steel diaphragm structure that does not require O-rings; High sensitivity; EMC and reverse polarition protection; Small and compact design| Pressure Range | Output | Protection | Accuracy | Body Diameter | Datasheet |
|---|---|---|---|---|---|
| Different options up to 2000 Bar | 4-20 mA, 0-10 VDC, 0-20 mA, 1-6 VDC, 0-5 VDC, Ratiometric | IP65 or IP67 | ±%0,5 F.S | 26mm |
Thin film steel diaphragm, flush membrane Stainless steel body Options from -0.5 ... 0.5 bar to 0 ... 100 bar ±0.5% FS sensitivity Different analog output options IP65, IP67 or IP68 protection class
Pressure transmitter with steel diaphragm and flush membrane; one-piece welded sealing body for high durability and resistance to ambient conditions; very small compact design; special smooth and flat flush membrane
| Measuring Range | Output | Protection | Accuracy | Datasheet |
|---|---|---|---|---|
| -0.5 ... 0.5 to 0 ... 100 bar | 4-20 mA, 0-10 VDC, 0-5 VDC, 1-6 VDC, 0.5-4.5 VDC ratiometric | IP65, IP67, IP68 | ±%0.5 FS |
-1…0~0.1bar…600bar pressure range Suitable for sanitary applications ±0.5%FS linearity 4-20 mA, 0-10V, 0-5V, 0.5-4.5V output IP65 protection class With cooling fan options, excellent performance for high temperature medium applications
Flush diaphragm; stainless steel body; high sensitivity; EMC and reverse polarity protection; for standard applications; high performance in high temperature applications up to 250°C with the option of cooling fan
0~0,0025bar…0,01bar…1bar pressure range Suitable for low pressure φ8 agnail connection, easy to install ±0.5%...±3%FS accuracy 4-20 mA analog output IP65 protection class
BFT10-110 Differential Pressure Transmitter is ideal for use at low pressures. Pressure connection is in M10 thread and agnail structure. It is widely used in the field of automatic pressure detection and control for air supply in underground ventilation and other electrical and mining industries.
| Pressure Range | Output | Protection | Accuracy | Datasheet |
|---|---|---|---|---|
| 0~0,0025bar…0,001bar…1bar | 4-20mA | IP 65 | ±0.5%...±3%FS |
Suitable for temperatures up to 300°C Can work with pressures up to 400 bar G1/2 or G1/4 connections
Pressure transmitter cooling elements are products that cool the body of the pressure transmitters in high temperature applications and protect them from temperature. It can be used in different connections with different inlet / outlet dimensions.| Maximum Pressure | Mechanical Connection | Maximum Temperature | Body | Datasheet |
|---|---|---|---|---|
| 400 Bar | G1/4F-G1/2M, G1/4F-G1/4M, G1/2F-G1/2M, G1/2F-G1/4M | 300°C | 316L Stainless Steel |
Linear Measurement
Rotary Measurement
Inclination/ Tilt Measurement
Laser Distance Sensors
Pressure Measurement
Level Measurement
Temperature Measurement
Liquid Flow Measurement
Proximity Sensors
Joysticks
Dro, Display and Counters
Elevator Light Curtains
Speed and Motion Measurement
Counting Sensors
Seismic / Earthquake Sensors
Mechanical Plunger Switches
Accelerometers
Faucet Sensors
Seam Detector Sensors
Encoder Signal Conditioner and Optical Isolator
Couplings
Cable and Connectors