IPS 200 Series Proximity Sensors || ATEK || Made in Türkiye
Detection of ferrous metal objects by inductive principle
17x17mm, 25x25mm and 30x30mm models
Rectangular type
DC 2-wire or 3-wire
LED status indicator
IP67 protection
Non-contact measurement of ferrous metal objects by inductive principle; DC 2-wire or 3-wire; rectangular body; various body dimension options; long service life
- Non-contact detection of ferrous metal objects by inductive principle
- 17x17mm, 25x25mm and 30x30mm models
- DC 2-wire or 3-wire
- High sensivity, fast feedback
- LED status indicator
- IP67 protection class
- Long service life
| Brand |
Atek |
|---|---|
| Measuring Type |
Inductive, non-contact |
| Sensing Distance (Sd) |
17 x 17 mm : 0 … 8 mm |
| Setting Distance |
17 x 17 mm : 0 … 5.6 mm |
| Standard Sensing Target |
17 x 17 mm : 25x25x1 |
| Sensing Object |
Ferrous Metal |
| Hystresis |
10% of Sensing distance (Sd) max. |
| Supply Voltage |
10…30 VDC (reverse polarity protection) |
| Current Consumption |
3-wire (PNP/NPN) : ≤15 mA |
| Leakage current, open state |
2-wire: ≤1 mA |
| Switching capacity |
3-wire : ≤200 mA with overload and short-circuit protection |
| Voltage drop, closed state |
3-wire : ≤1,5 V |
| Internal Pull Up / Pull-Down Resistance |
3-wire:22K |
| Response Frequency |
3-wire : 2 kHz |
| First up delay |
3-wire : 20ms |
| Electrical Connection |
3 x 0.14mm² PVC cable (Ø4,5 ± 0,10 mm) |
| Status Indicator |
If there is a target : blue |
| Protection |
IP67 |
| Operating Temperature |
-20…+70°C |
| Material |
Body: Plastic |
In the automation industry;
- Position monitoring of machine parts
- Counting metal objects
Benzer Ürünler
II 1G Ex ia IIC T4/T6 Ga II 1D Ex ia IIIC T120°C / T85°C Da ATEX ve IECEx Ex Zones 0, 1, 2 (gas); 20, 21, 22 (dust) Different models available from 100 mBar to 600 Bar nalog output (4-20mA / 0-10V, etc.) or CANopen output ±%0,3 F.S accuracy IP65 or IP67 protection Compact design
ATEX certified for use in explosive atmospheres; high accuracy; protected against EMC and reverse polarity; small and compact designThin-film steel diaphragm structure 26 mm diameter stainless steel housing Different options up to 2000 Bar Analog 4-20mA / 0-10V etc. outputs ±%0,5 F.S accuracy Compact design
Fully welded Thin-film steel diaphragm structure that does not require O-rings; High sensitivity; EMC and reverse polarition protection; Small and compact design| Pressure Range | Output | Protection | Accuracy | Body Diameter | Datasheet |
|---|---|---|---|---|---|
| Different options up to 2000 Bar | 4-20 mA, 0-10 VDC, 0-20 mA, 1-6 VDC, 0-5 VDC, Ratiometric | IP65 or IP67 | ±%0,5 F.S | 26mm |
Resistant to most oils, fuels, hydraulics, dust and solvents Mechanical switch for 10mA - 5A at 9-32VDC Vibration (5G) resistant Designed to allow both vertical and angular movement Standard NO, optional NC switch output IP67 protection class
Oil, fuel, hydraulic and dust resistant; resistant to vibrations; commercial vehicles, industrial equipment, conveyor systems, etc. Status detection and output for many different situations that may occur in systems| Voltage and Current Range | temperature Range | Body Diameter | Output | Protection | Datasheet |
|---|---|---|---|---|---|
| 12-24V / 10mA-5A | -40°C ... +150°C | 26mm | NC or NO | IP67 |
Detection of ferrous metal objects by inductive principle Ø8, Ø12, Ø18 or Ø30 mm models DC 2-wire or 3-wire Non-flush LED status indicator IP67 protection
Non-contact measurement of ferrous metal objects by inductive principle; DC 2-wire or 3-wire; various body diameter options; long service life
Shaking detection in 3 axes Thanks to its automatic offset feature, that is, its location detection feature, it is ready to detect earthquakes without the need to make any settings. Thanks to the fire/gas detector and fire button input on it; In addition to detecting the earthquake, other alarm situations can also be monitored 4 dry contact relay outputs (220VDC/250VAC or 24VDC); Audible warning with buzzer and visual warning with LEDs in case of earthquake and fire Small structure, easy mounting
Shaking detection in 3 axes; In addition to earthquake detection, other alarm situations can be monitored with the external fire/gas detector and fire button input; With 4 dry contact relay outputs, systems such as elevators, electricity, emergency lighting etc. can be controlled in case of earthquake or fire; audible warning in case of earthquake; small and compact structureProvides optical isolation between the encoder signal and PLC, servo driver or other input devices Can change the encoder's signal voltage to match the receiver input Converts non-differential output (A, B, Z) to differential output (A, B, Z, A/, B/, Z/) Converts differential output (A, B, Z, A/, B/, Z/) to non-differential output (A, B, Z) Converts open collector output to differential or non-differential output Easy mounting on panels with DIN Rail system
Versatile interface between incremental encoder and receiving devices; Ability to convert non-differential signal to differential, differential signal to non-differential; cleaning noisy signals; adjusting the encoder signal voltage according to the receiver; DIN rail system
Linear Measurement
Rotary Measurement
Inclination/ Tilt Measurement
Laser Distance Sensors
Pressure Measurement
Level Measurement
Temperature Measurement
Liquid Flow Measurement
Proximity Sensors
Joysticks
Dro, Display and Counters
Elevator Light Curtains
Speed and Motion Measurement
Counting Sensors
Seismic / Earthquake Sensors
Mechanical Plunger Switches
Accelerometers
Faucet Sensors
Seam Detector Sensors
Encoder Signal Conditioner and Optical Isolator
Couplings
Cable and Connectors