ASM10 Siesmic Earthquake Panel || ATEK || Made In Türkiye
Shaking detection in 3 axes
Thanks to its automatic offset feature, that is, its location detection feature, it is ready to detect earthquakes without the need to make any settings.
Thanks to the fire/gas detector and fire button input on it; In addition to detecting the earthquake, other alarm situations can also be monitored
4 dry contact relay outputs (220VDC/250VAC or 24VDC);
Audible warning with buzzer and visual warning with LEDs in case of earthquake and fire
Small structure, easy mounting
Shaking detection in 3 axes; In addition to earthquake detection, other alarm situations can be monitored with the external fire/gas detector and fire button input; With 4 dry contact relay outputs, systems such as elevators, electricity, emergency lighting etc. can be controlled in case of earthquake or fire; audible warning in case of earthquake; small and compact structure
ASM 20 Seismic Earthquake Sensors have very sensitive sensors that can detect seismic movements in three axes (x,y,z,). It detects the seismic vibrations that occur during an earthquake and gives control output and it is designed to automatically disable the devices such as generators, electrical panels, elevators, etc. that may pose a danger during an earthquake. If such movements are detected, it also provides an audible warning with a buzzer and a visual warning with LEDs. Thus, the damages that may occur as a result of the earthquake are minimized.
Additionally, there is 1 fire/gas detector input and 1 fire alarm button input on the device. If desired, a fire alarm button can be connected to the button input, and a gas alarm detector, smoke detector and other systems that are desired to be monitored can be connected to the fire/gas detector input. In this way, earthquakes can be detected and alarm conditions from other systems can be monitored through a single device.
The device has 4 dry contact relay outputs. 2 of the relay outputs are activated during an earthquake and 2 of them are activated when an alarm comes from an externally connected button or detector.
- Shaking detection in 3 axes
- Thanks to its automatic offset feature, that is, its location detection feature, it is ready to detect earthquakes without the need to make any settings.
- There is 1 fire/gas detector input and 1 fire alarm button input on the sensor. If desired, you can connect the fire alarm button to the button input; Gas alarm detector, smoke detector and other systems that are desired to be monitored can be connected to the fire/gas detector input. In this way, earthquakes can be detected and alarm conditions from other systems can be monitored through a single device.
- 24VDC supply voltage
- 4 dry contact relay outputs (220VDC/250VAC or 24VDC);
Earthquake relays are activated when an earthquake is detected,
- Fire relays are activated when an alarm comes from the external gas/fire detector or fire button input.
- Audible warning with buzzer and visual warning with LEDs in case of earthquake and fire
- Robust and durable
- Small structure, easy mounting
| Brand |
Atek |
|---|---|
| TECHNICAL FEATURES |
–> |
| Operating Voltage |
12-24 VDC |
| Quiescent Current |
20mA @24VDC |
| Alarm Current |
150mA @24VDC |
| Detection Plane |
X, Y, Z (3 axis) |
| Frequency Sensitivity Range |
1…7,7Hz |
| Min. sensitive acceleration threshold |
+/- 40 mg |
| External Inputs |
1 x alarm button |
| Relay Output |
4 x dry contact relays |
| Buzzer |
85dB/1m |
| Operating Temperature |
-10°C … +60°C |
| Relative humudity |
%10…%90 non-condensing |
| Housing Material |
Metal |
ASM 20 Seismic Earthquake Sensors have very sensitive sensors that can detect seismic movements in three axes (x,y,z,). It detects the seismic vibrations that occur during an earthquake and gives control output and it is designed to automatically disable the devices such as generators, electrical panels, elevators, etc. that may pose a danger during an earthquake. If such movements are detected, it also provides an audible warning with a buzzer and a visual warning with LEDs. Thus, the damages that may occur as a result of the earthquake are minimized.Additionally, there is 1 fire/gas detector input and 1 fire alarm button input on the device. If desired, a fire alarm button can be connected to the button input, and a gas alarm detector, smoke detector and other systems that are desired to be monitored can be connected to the fire/gas detector input. In this way, earthquakes can be detected and alarm conditions from other systems can be monitored through a single device.
Benzer Ürünler
Spring-return (self-return) 60°, 110° or 120° electrical angle 120° or 150° limited mechanical angle M6x1 threaded shaft (optional others) 30 mm body diameter Potentiometric output ±%1 linearity 2 million cycyles lifetime IP67 protection
Rotary potentiometer with spring return; Up to 2 million movement life; Self-return feature; potentiometric output, high protection class| Measuring Range | Shaft Diameter | Body Diameter | Output Type | Protection | Linearity | Datasheet |
|---|---|---|---|---|---|---|
| Electrical Ang: 60°, 110°, 120° Mechanical Ang: 120°, 150° |
M6x1 |
30 mm |
Potentiometric |
IP67 |
±%1 |
Thin-film steel diaphragm structure 26 mm diameter stainless steel housing Different options up to 2000 Bar Analog 4-20mA / 0-10V etc. outputs ±%0,5 F.S accuracy Compact design
Fully welded Thin-film steel diaphragm structure that does not require O-rings; High sensitivity; EMC and reverse polarition protection; Small and compact design| Pressure Range | Output | Protection | Accuracy | Body Diameter | Datasheet |
|---|---|---|---|---|---|
| Different options up to 2000 Bar | 4-20 mA, 0-10 VDC, 0-20 mA, 1-6 VDC, 0-5 VDC, Ratiometric | IP65 or IP67 | ±%0,5 F.S | 26mm |
Resistant to most oils, fuels, hydraulics, dust and solvents Mechanical switch for 10mA - 5A at 9-32VDC Vibration (5G) resistant Designed to allow both vertical and angular movement Standard NC, optional NO switch output Industry standard AMP superseal connector IP69K protection class
Oil, fuel, hydraulic and dust resistant; resistant to vibrations; commercial vehicles, industrial equipment, conveyor systems, etc. Status detection and output for many different situations that may occur in systems| Voltage and Current Range | temperature Range | Body Diameter | Output | Protection | Datasheet |
|---|---|---|---|---|---|
| 12-24V / 10mA-5A | -40°C ... +150°C | 27mm | NC or NO | IP69K |
- Pressure and temperature measurement with a single sensor
- Piezoresistive operating principle
- 26 mm stainless steel housing
- Pressure ranges from 60 bar to 600 bar
- Temperature measurement from -40 … +125°C
- 4-20 mA, 0-10 V, 0.5-4.5 V Ratiometric, PT100, PT1000 output options
- G1/4, G1/2, NPT1/4, NPT1/2, M14x1 mechanical connection options
- High accuracy and stability
BCT 24S series combined pressure and temperature sensors enable pressure and temperature measurement in liquid and gaseous media using a single sensor. The cooling element used in high-temperature applications protects the sensor, ensuring reliable measurement.
Pressure and temperature measurement with a single sensor Completely welded thin-film steel diaphragm structure that does not require o-ring Pressure measuring range options from 0…10 bar to 0…2000 bar (optional others) -40 … +150°C temperature measurement (optional others) 4-20mA, 0-10V, 0.5-4.5V Ratiometric, PT100, PT1000 output options High accuracy and stability
Measurement of both pressure and temperature via a single sensor; Fully welded Thin-film steel diaphragm structure that does not require O-rings; high sensitivity; EMC and reverse polarization protection; wide range of analog output and mechanical connection optionsDetection of ferrous metal objects by inductive principle 17x17mm, 25x25mm and 30x30mm models Rectangular type DC 2-wire or 3-wire LED status indicator IP67 protection
Non-contact measurement of ferrous metal objects by inductive principle; DC 2-wire or 3-wire; rectangular body; various body dimension options; long service life