MLS 130 Series Magnetic Reader Sensor || ATEK || Made in Türkiye
Magnetic measurement
Small size
Easy mounting
Measure up to 100 meters
Resolution from 1 μm to 100 μm
Spiral or PUR cable option
IP67 protection class
Reader sensor capable of contactless measurement on magnetic tape; the perfect solution for tight spaces with very small size; it is completely insensitive to factors such as moisture, oil, dust, etc.; models with cable or spiral
Measuring Range | Output | Protection | Magnetic Tape | Resolution | Datasheet |
---|---|---|---|---|---|
Up to 100 meters |
Push-Pull, TTL RS422 Line Driver
|
IP 67 | B2, B5 |
1 µm, 5 µm, 10 µm, 25 µm, 62.5 µm, 80µm, 100µm, others on request
|
![]() |
- Very small size
- Easy mounting
- Resolution from 1 μm to 100 μm
- High accuracy and repeatability
- Spiral and wired options
- Measure up to 100 meters
- Dust, oil and moisture-insensitive
- Rugged aluminum body
- IP67 protection class
*We highly recommend using our Process Control Devices to precisely display measured values on your Magnetic Linear Scale for motion conrolling, and our DRO(Digital Readout) Displays to use on metal working machines such as CNC, lathe etc.
Brand |
Atek |
---|---|
Measuring Range |
Up to 100 meters |
Resolution |
1µm, 5µm, 10µm, 25µm, 50µm, 62.5µm, 80µm, 100µm (others on request) |
Measuring Principle |
Magnetic |
Output Type |
Push-Pull or TTL RS422 Line Driver |
Magnetic Tape |
B1, B2, B5 |
Output Signals |
A, /A, B, /B, Z, /Z |
Input Current |
Maximum 40 mA per channel |
Supply Voltage |
PP: 10..30 VDC or TTL: 5 VDC |
Housing Material |
Aluminum |
Electrical Connection |
D-Sub 9 pin, 5 or 8 x 0,14 mm2 shielded cable |
Operating Speed |
3 m/s |
Repeatability |
± 1 Pulse |
Operating Temperature |
-25°C … +85°C |
Protection Class |
IP67 |
- Machinery Industry
- PVC Cutting Machines
- Woodworking Machines
- Presses
- Textile Machinery
- Marble Machines
- Transfer Machines
- Saws
- Metal Processing Machines
- Turning, Milling
- Bohrwerk
- Dragline
- Automation and Robots
Benzer Ürünler
Non-contact inductive measuring principle High linearity: 0.1% 0-20 mA or 4-20 mA analog output options Extra robust housing Long life IP67 or IP50 protection class
Inductive principle with absolute and very precise measurement; unlimited mechanical life due to non-contact; extra durability thanks to fully enclosed body; linear scale which is not affected by temperature changes thanks to special coilMeasuring Range | Output | Protection | Linearity | Datasheet |
---|---|---|---|---|
10 mm | Analog (0-20 mA, 4-20 mA) | IP67 | ±0,1 %FS | ![]() |
Non-contact magnetostrictive measurement Screw Flange Rod type body Absolute operating Operating pressure up to 350 bar Analog output options High precision up to 0.04% IP67 protection class
Non-contact and magnetostrictive measuring principle; internal connection to hydraulic or pneumatic cylinders; absolute operation, that is, not to lose position information in case of power failureMeasuring Range | Output | Protection | Linearity | Datasheet |
---|---|---|---|---|
50 - 2000 mm | Analog (0.5-4.5 V, 0.25-4.75 V, 0-10 V, 4-20 mA) | IP 67 | ≤±%0,04 FS | ![]() |
Precise potentiometric measurement Different measuring lengths from 10 mm to 300 mm Linearity up to 0.05% <0.01 mm high resolution Motion life of up to 100 million Articulated, Rod and Spring model options IP54 protection class
Precise position measurement; Easy installation with compact and small design; 3 different body options: Articulated, Rod and Spring; cost effective solutionMeasuring Range | Output | Protection | Linearity | Datasheet |
---|---|---|---|---|
Different measuring lengths between 10 mm and 300 mm | Analog (potentiometric) | IP 54 | ±%0,05 | ![]() |
Precise potentiometric measurement Different measuring lengths from 25 mm to 150 mm Superior linearity up to 0.075% Motion life of up to 100 million Cable or socket version IP40 protection class
Precise and cost-effective position measurement; compact design; high speed operation; High repeatability value: 0.002 mm
Measuring Range | Output | Protection | Linearity | Datasheet |
---|---|---|---|---|
Different measuring lengths between 25mm and 150 mm | Analog (potentiometric) | IP 40 | ±%0,075 | ![]() |
Precise potentiometric measurement Different measuring lengths from 10 mm to 100 mm High resolution: <0.05 mm ± 1% linearity Motion life of up to 10 million Springless and back spring model options IP65 protection class
Precise and cost-effective position measurement; compact design; high speed operation; optional push back spring
Measuring Range | Output | Protection | Linearity | Datasheet |
---|---|---|---|---|
Different measuring lengths between 10 mm and 100 mm | Analog (potentiometric) | IP 65 | ±%1 | ![]() |
Stroke options from 100 mm to 1000 mm Incremental optical system Slim body type Reference point at 50 mm intervals High resolution options up to 1 μm IP54 protection class 60 m/min operating speed
Optical precision measurement on glass surface; thin body with single or double gasket protection; 5 ball bearing system orientation; compact design, high accuracyMeasuring Range | Output Type | Protection | Resolution | Datasheet |
---|---|---|---|---|
Different measuring lengths from 100 mm to 1000 mm |
TTL RS-422
or Sinus |
IP 54 | 1µm, 5µm | ![]() |