MLS 120 / 121 Series Magnetic Reader Sensor || ATEK || Made in Türkiye
Magnetic measurement
Small size
Easy mounting
Measure up to 100 meters
Resolution from 1 μm to 100 μm
Model with cable or socket
Spiral or PUR cable option
IP67 protection class
Reader sensor for contactless measurement on magnetic tape; internal tape slider against dust; extra durability against environmental factors such as moisture, oil, dust; model with cable or socket
Measuring Range | Output | Protection | Magnetic Tape | Resolution | Datasheet |
---|---|---|---|---|---|
Up to 100 meters |
Push-Pull, TTL RS422 Line Driver
|
IP 67 | B2, B5 |
1µm, 5 µm, 10µm, 25µm, 62.5µm, 80µm, 100µm, others on request
|
- Easy assembly
- High accuracy and repeatability
- Model with socket or cable
- Spiral or PUR cable option
- Measure up to 100 meters
- Rugged aluminum body
- IP67 protection class
- With integrated slider on the sensor body, there is extra protection from external factors such as dust, dirt, sawdust which may be formed on the magnetic tape or profile that it moves on
Brand |
Atek |
---|---|
Measuring Range |
Up to 100 meters |
Resolution |
1µm, 5µm, 10µm, 25µm, 50µm, 62.5µm, 80µm, 100µm (others on request) |
Measuring Principle |
Magnetic |
Output Type |
Push-Pull or TTL RS422 Line Driver |
Magnetic Tape |
B2, B5 |
Output Signals |
A, /A, B, /B, Z, /Z |
Input Current |
Maximum 40 mA per channel |
Supply Voltage |
PP: 10..30 VDC or TTL: 5 VDC |
Housing Material |
Aluminum |
Electrical Connection |
D-Sub 9 pin, 5 or 8 x 0,14 mm2 shielded cable |
Operating Speed |
3 m/s |
Repeatability |
± 1 Pulse |
Operating Temperature |
-25°C … +85°C |
Protection Class |
IP67 |
- Machinery Industry
- PVC Cutting Machines
- Woodworking Machines
- Presses
- Textile Machinery
- Marble Machines
- Transfer Machines
- Saws
- Metal Processing Machines
- Turning, Milling
- Bohrwerk
- Dragline
- Automation and Robots
Benzer Ürünler
Non-contact inductive measuring principle High linearity: 0.1% 0-20 mA or 4-20 mA analog output options Extra robust housing Long life IP67 or IP50 protection class
Inductive principle with absolute and very precise measurement; unlimited mechanical life due to non-contact; extra durability thanks to fully enclosed body; linear scale which is not affected by temperature changes thanks to special coilMeasuring Range | Output | Protection | Linearity | Datasheet |
---|---|---|---|---|
10 mm | Analog (0-20 mA, 4-20 mA) | IP67 | ±0,1 %FS |
Precise potentiometric measurement Different measuring lengths from 50 mm to 750 mm Linearity up to 0.04% <0.01 mm high resolution Motion life of up to 50 million IP65 protection class
Precise position measurement with robust housing; Easy to install with double beared actuating rod; Mountable via free from backlash pivot heads with a large angle of free movement
Measuring Range | Output | Protection | Linearity | Datasheet |
---|---|---|---|---|
Different measuring lengths between 50 mm and 750 mm | Analog (potentiometric) | IP 65 | ±%0,04 |
Precise potentiometric measurement Different measuring lengths from 10 mm to 100 mm Superior linearity up to 0.04% High resolution: <0.01 mm Motion life of up to 50 million Cable or socket versions IP67 protection class
Precise position measurement with extra durable housing; easy mounting with ball joint at both sides; extra long life thanks to the special membrane that compensates the pressure on the shaft; extra protection against vibrations and corrosion
Measuring Range | Output | Protection | Linearity | Datasheet |
---|---|---|---|---|
Different measuring lengths between 50 mm and 750 mm | Analog (potentiometric) | IP 67 | ±%0.04 |
Precise potentiometric measurement Different measuring lengths from 10 mm to 100 mm High resolution: <0.05 mm ± 1% linearity Motion life of up to 10 million Springless and back spring model options IP65 protection class
Precise and cost-effective position measurement; compact design; high speed operation; optional push back spring
Measuring Range | Output | Protection | Linearity | Datasheet |
---|---|---|---|---|
Different measuring lengths between 10 mm and 100 mm | Analog (potentiometric) | IP 65 | ±%1 |
Stroke options from 100 mm to 1000 mm Incremental optical system Slim body type Reference point at 50 mm intervals High resolution options up to 1 μm IP54 protection class 60 m/min operating speed
Optical precision measurement on glass surface; thin body with single or double gasket protection; 5 ball bearing system orientation; compact design, high accuracyMeasuring Range | Output Type | Protection | Resolution | Datasheet |
---|---|---|---|---|
Different measuring lengths from 100 mm to 1000 mm |
TTL RS-422
or Sinus |
IP 54 | 1µm, 5µm |
Stroke options from 100 mm to 3200 mm Incremental optical system Thick and long-distance body type Reference point at 50 mm intervals High resolution up to 1 μm IP54 protection class 60 m/min operating speed
Precise measurement on glass surface with optical principle; thick, long-distance body with single seal; 5 ball bearing system orientation; compact design, high accuracyMeasuring Range | Output Type | Protection | Resolution | Datasheet |
---|---|---|---|---|
Different measuring lengths from 100 mm to 3200 mm |
TTL RS-422
or Sinus |
IP 54 | 1µm, 5µm |