BHT 26 Flush Pressure Transmitter for Sanitary Applications || ATEK ||
100mbar…100bar pressure range
Suitable for sanitary applications
Suitable for 1.5″ tri-clamp connection
±0.5%FS accuracy
4-20 mA, 0-10V etc. analog output options
IP65 protection
BT10-211 flush pressure transmitter is applicable to food, beverage, pharmaceutical and biological engineering. Full metal flush-mounting isolation diaphragm is directly welded with process connection to ensure the precision connection between process connection and measuring diaphragm. Therefore, no additional sealing gaskets are required, and it ensures there are no measurement dead zones.
| Pressure Range | Output | Protection | Accuracy | Datasheet |
|---|---|---|---|---|
| 0…100 mBar to 0…100 Bar | 4-20mA, 0-20mA, 0-10V, 1-6V, 0-5V, Ratiometric | IP 65 | ±0.5%FS |
- SS316L isolation diaphragm structure
- Suitable for 1.5″ tri-clamp connection
- 26 mm diameter stainless steel housing
- Different options from 100 mBar to 100 Bar
- 4…20mA / 0…10VDC etc. Different analog output options
- Suitable for process temperature up to 120°C
- EMC and reverse polarity protection
- High accuracy and stability
- IP65 protection class
| Brand |
Atek |
|---|---|
| Pressure range |
Different options from 100 mBar to 100 Bar |
| Supply and Output |
4~20mA (8~32VDC) |
| Accuracy |
% 0.5FS |
| Hysteresis and repeatability |
% 0.1FS |
| Response time |
≤1ms (FS’e kadar) |
| Service life |
1×10⁶ pressure cycles |
| Operating temperature |
-40°C … +120°C |
| Storage temperature |
-40°C … +120°C |
| EMC |
Immunity: IEC 61000-6-2, Radiation: IEC 61000-6-3 |
| Insulation resistance |
≥200MΩ/250VDC |
| Protection |
IP65 |
| Medium compatibility |
All kinds of media compatible with SS316L |
- Oil and gas, compressed air, steam, liquid, paste and powder media
- Vacuum pressure detection such as vacuum transfer pump monitoring
Benzer Ürünler
Thin film steel diaphragm, flush membrane Stainless steel body Options from -0.5 ... 0.5 bar to 0 ... 100 bar ±0.5% FS sensitivity Different analog output options IP65, IP67 or IP68 protection class
Pressure transmitter with steel diaphragm and flush membrane; one-piece welded sealing body for high durability and resistance to ambient conditions; very small compact design; special smooth and flat flush membrane
| Measuring Range | Output | Protection | Accuracy | Datasheet |
|---|---|---|---|---|
| -0.5 ... 0.5 to 0 ... 100 bar | 4-20 mA, 0-10 VDC, 0-5 VDC, 1-6 VDC, 0.5-4.5 VDC ratiometric | IP65, IP67, IP68 | ±%0.5 FS |
Suitable for use in explosive environments Atex certified Stainless steel or titanium body Options from 0 ... 0.1 bar to 0 ... 25 bar ±0.1% FS, ±0.25% FS or ±0.5% FS sensitivity 4-20 mA analog output IP68 protection class
Piezoresistive submersible pressure transmitter; Ex-Proof certified, explosion-proof; Stainlees steel or titanium body PUR or FEP cable options| Measuring Range | Output | Protection | Accuracy | Datasheet |
|---|---|---|---|---|
| 0 ... 0.1 to 0 ... 25 bar | 4-20 mA |
IP68 |
±%0.1 FS, ±%0.25 FS, ±%0.5 FS |
Thin film steel diaphragm Stainless steel body Options from 0 ... 2,5 bar to 0 ... 600 bar ±0.3% FS, ± 0.15% FS, ± 0.1% FS accuracy Different analog output options IP 65 or IP67 protection class
Pressure transmitter with steel diaphragm ; high sensitivity values; one-piece welded sealing body for high durability and resistance to ambient conditions; smallest compact design; extra high pressure resistance
| Measuring Range | Output | Protection | Accuracy | Datasheet |
|---|---|---|---|---|
| 0 ... 2.5 to 0 ... 600 bar | 4-20 mA, 0-5 VDC, 0-10 VDC, 1-6 VDC, 0.5-4.5 VDC ratiometric | IP65, IP67 | ±%0.3 FS, ±%0.15 FS, ±%0.1 FS |
0~0,0025bar…0,01bar…1bar pressure range Suitable for low pressure φ8 agnail connection, easy to install ±0.5%...±3%FS accuracy 4-20 mA analog output IP65 protection class
BFT10-110 Differential Pressure Transmitter is ideal for use at low pressures. Pressure connection is in M10 thread and agnail structure. It is widely used in the field of automatic pressure detection and control for air supply in underground ventilation and other electrical and mining industries.
| Pressure Range | Output | Protection | Accuracy | Datasheet |
|---|---|---|---|---|
| 0~0,0025bar…0,001bar…1bar | 4-20mA | IP 65 | ±0.5%...±3%FS |
Pressure Switch with indicator Options from 0 ... 0.2 bar to 0 ... 100 bar ±0.5% FS sensitivity Analog output options 2 PNP transistor outputs IP67 protection class
Pressure transmitter and switch with indicator in one device; thick film ceramic diaphragm; programming from mobile phone with NFC; current and voltage output option in one device; absolute or relative measurement; 2 PNP transistor outputs
| Measuring Range | Output | Protection | Accuracy | Datasheet |
|---|---|---|---|---|
| 0 ... 0.2 to 0 ... 100 bar | 4-20 mA, 0-10 VDC, 0-5 VDC, 1-6 VDC, switchable mA or V, PNP transistor | IP67 | ±0.5% FS |
Pressure switch with display -1 bar...10 bar pressure range ±2% FS accuracy Analog and transistor output Multiple measuring unit option
Pressure switch with ultra-low power consumption; multiple measurement unit option; analog and open collector output; high performance LCD display| Pressure Range | Output | Protection | Accuracy | Datasheet |
|---|---|---|---|---|
| -1bar ... 10bar | 4-20 mA, 1-5 VDC, PNP/NPN Open Collector |
IP40 |
±2% FS |
Linear Measurement
Rotary Measurement
Inclination/ Tilt Measurement
Laser Distance Sensors
Pressure Measurement
Level Measurement
Temperature Measurement
Liquid Flow Measurement
Proximity Sensors
Joysticks
Dro, Display and Counters
Elevator Light Curtains
Speed and Motion Measurement
Counting Sensors
Seismic / Earthquake Sensors
Mechanical Plunger Switches
Accelerometers
Faucet Sensors
Seam Detector Sensors
Encoder Signal Conditioner and Optical Isolator
Couplings
Cable and Connectors