DPS 2 Series Pressure Switch With Display || ATEK ||
Pressure switch with display
-1 bar…10 bar pressure range
±2% FS accuracy
Analog and transistor output
Multiple measuring unit option
Pressure switch with ultra-low power consumption; multiple measurement unit option; analog and open collector output; high performance LCD display
| Pressure Range | Output | Protection | Accuracy | Datasheet |
|---|---|---|---|---|
| -1bar … 10bar | 4-20 mA, 1-5 VDC, PNP/NPN Open Collector |
IP40
|
±2% FS |
- Pressure switch with display
- -1 bar…10 bar pressure range
- ±2% FS accuracy
- Analog and transistor output
- Multiple measuring unit option
| Brand |
Atek |
|---|---|
| TECHNICAL FEATURES |
–> |
| Measuring range |
-1bar ~10bar |
| Withstand pressure |
15bar |
| Measure accuracy |
≤±2%F.S. (ambient temperature 25°C) |
| Temperature error |
≤±3%F.S. (temperature range 0~50°C) |
| Measure pattern |
Hysterersis mode |
| Port size |
External R1/8, NPT1/8, G1/8 option, internal therad M5 |
| Display |
Double LCD display |
| Supply voltage |
12-24VDC ± |
| Transistor output |
NPN or PNP Open Collector |
| Analog output |
1-5V or 4-20mA |
| Short-circuit protection |
Yes |
| Protection class |
IP40 |
| Ambient temperature |
Operating temperature 0~50°C, storage temperature -20~60°C |
| Insulation voltage |
1000VAC 1 min |
| Insulation resistance |
≤50MΩ(500VDC) |
| Shock |
Max 100m/s2, 3 times each in directions of X, Y and Z |
| Vibration |
Amplitude 1.5mm. 10Hz-500Hz, 2 hours each direction of X, Y and Z |
Benzer Ürünler
Ceramic diaphragm Stainless steel body Options from 0 ... 1 bar to 0 ... 400 bar ±0.5% FS sensitivity Different analog output options IP65, IP67 or IP68 protection class Economical and convenient solution Datashee
Pressure transmitter with ceramic diaphragm; economical and durable solution; relative or absolute measurement option
| Measuring Range | Output | Protection | Accuracy | Datasheet |
|---|---|---|---|---|
| 0 ... 1 to 0 ... 400 bar | 4-20 mA, 0-10 VDC, 0.5-4.5 VDC ratiometric, 0-5 VDC, 1-6 VDC | IP65, IP67, IP68 | ±%0.5 FS |
Thin film steel diaphragm Stainless steel housing, high pressure resistant Measurements from 0 ... 2,5 bar to 0 ... 600 bar High sensitivity of ±0.3% and ±0.5% FS Different analog output options Wide temperature range up to 125°C IP65, IP67 or IP68 protection class
Pressure transmitter with steel diaphragm; one-piece welded sealing body provides high durability and resistance to ambient conditions; very small compact design
| Measuring Range | Output | Protection | Accuracy | Datasheet |
|---|---|---|---|---|
| 0 ... 2.5 to 0 ... 600 bar | 4-20 mA, 0-10 VDC, 0.5-4.5 VDC ratiometric, 0-5 VDC, 1-6 VDC | IP65, IP67, IP68 | ±%0.5 FS, ±%0.3 FS |
Thick film ceramic diaphragm Stainless steel body Options from 0 ... 0.1 bar to 0 ... 6 bar ±0.3% FS accuracy 4-20 mA analog output IP68 protection class
Submersible pressure transmitter with ceramic diaphragm; suitable for pressure measurement of dense and viscous substances; protected against lightning strikes; PUR or PE cable options
| Measuring Range | Output | Protection | Accuracy | Datasheet |
|---|---|---|---|---|
| 0 ... 0.1 to 0 ... 6.0 bar | 4-20 mA | IP68 | ±%0.3 FS |
Suitable for use in explosive environments Atex certified Stainless steel or titanium body Options from 0 ... 0.1 bar to 0 ... 25 bar ±0.1% FS, ±0.25% FS or ±0.5% FS sensitivity 4-20 mA analog output IP68 protection class
Piezoresistive submersible pressure transmitter; Ex-Proof certified, explosion-proof; Stainlees steel or titanium body PUR or FEP cable options| Measuring Range | Output | Protection | Accuracy | Datasheet |
|---|---|---|---|---|
| 0 ... 0.1 to 0 ... 25 bar | 4-20 mA |
IP68 |
±%0.1 FS, ±%0.25 FS, ±%0.5 FS |
100mbar…100bar pressure range Suitable for sanitary applications Suitable for 1.5" tri-clamp connection ±0.5%FS accuracy 4-20 mA, 0-10V etc. analog output options IP65 protection
BT10-211 flush pressure transmitter is applicable to food, beverage, pharmaceutical and biological engineering. Full metal flush-mounting isolation diaphragm is directly welded with process connection to ensure the precision connection between process connection and measuring diaphragm. Therefore, no additional sealing gaskets are required, and it ensures there are no measurement dead zones.| Pressure Range | Output | Protection | Accuracy | Datasheet |
|---|---|---|---|---|
| 0...100 mBar to 0...100 Bar | 4-20mA, 0-20mA, 0-10V, 1-6V, 0-5V, Ratiometric | IP 65 | ±0.5%FS |
Pressure Switch with indicator Options from 0 ... 0.2 bar to 0 ... 100 bar ±0.5% FS sensitivity Analog output options 2 PNP transistor outputs IP67 protection class
Pressure transmitter and switch with indicator in one device; thick film ceramic diaphragm; programming from mobile phone with NFC; current and voltage output option in one device; absolute or relative measurement; 2 PNP transistor outputs
| Measuring Range | Output | Protection | Accuracy | Datasheet |
|---|---|---|---|---|
| 0 ... 0.2 to 0 ... 100 bar | 4-20 mA, 0-10 VDC, 0-5 VDC, 1-6 VDC, switchable mA or V, PNP transistor | IP67 | ±0.5% FS |