Potentiometric measurement
Electrical measuring angle of 100°, 308° or 345°
Shaft diameter of 6 mm
Linearity up to ±0.3%
120 RPM operating speed
Motion life of up to 50 million
IP67 protection class
High precision, circular potentiometer with shaft; more than 50 million movement life; infinite and continuous rotation; easy installation with two different shaft options, marked or push-on
| Measurement Range | Shaft Diameter | Protection | Linearity | Datasheet |
|---|---|---|---|---|
| 100°, 308° or 345° electrical measurement |
6 mm
|
IP67
|
±%0.3 |
- High precision rotary potentiometer with integrated shaft
- Electrical measurement of 100°, 308° or 345°
- Linearity up to 0.3%
- Easy installation with two different shafts, marked or push-on
- Shaft diameter of 6 mm
- IP67 protection class
- Long life with high durability: more than 50 million movements
- Superior German technology
| Brand |
Novotechnic |
|---|---|
| Electrical Measurement Range |
100°, 308° and 345° |
| Resistance Values |
3, 5 kΩ |
| Resistance tolerance |
±% 20 |
| Repeatability |
%0,3'e kadar |
| Max supply voltage |
42 V |
| Recommended wiper current |
≤ 1μA |
| Max. wiper current in case of malfunction |
10 mA |
| Isolation resistance (500VDC, 1bar, 2s) |
≥10 MΩ |
| Mounting |
2 fillister head screws M4 with washers |
| Maximum torque for mounting screws |
180 Nm |
| Max. shaft load |
20 N |
| Operating temperature |
-40 … +150 °C |
| Life |
50 x 106 movements |
| Operating speed |
120 RPM |
| Protection class |
IP67 |
Benzer Ürünler
Incremental measurement with magnetic principle 37 mm body diameter 4, 5 or 6 mm end hollow shaft options Resolution options from 1 to 1024 pulses Durable up to 3000 RPM IP54 protection class
Extremely resistant to harsh environmental conditions with magnetic mesauring principle; incremental precision measurement; 37 mm body diameter; different end hollow shaft options
| Resolution | Shaft Diameter | Body Diameter | Output | Protection | Datasheet |
|---|---|---|---|---|---|
| Different options from 1 to 1024 pulses | 4, 5 or 6 mm | 37 mm | Push-Pull, TTL Line Driver, Open Collector | IP 54 |
Incremental measurement with magnetic principle 37 mm body diameter 6, 8 or 10 mm shaft options Resolution options from 1 to 1024 pulses Durable up to 3000 RPM IP54 protection class
Extremely resistant to harsh environmental conditions with magnetic mesauring principle; incremental precision measurement; 37 mm body diameter; different shaft options
| Resolution | Shaft Diameter | Body Diameter | Output | Protection | Datasheet |
|---|---|---|---|---|---|
| Different options from 1 to 1024 pulses | 6, 8 or 10 mm | 37 mm | Push-Pull, TTL Line Driver, Open Collector | IP 54 |
Incremental measurement with magnetic principle 37 mm body diameter Different hollow shaft options from 4 to 10 mm Resolution options from 1 to 1024 pulses Durable up to 3000 RPM IP54 protection class
Extremely resistant to harsh environmental conditions with magnetic mesauring principle; incremental precision measurement; 37 mm body diameter; different end hollow shaft options
| Resolution | Shaft Diameter | Body Diameter | Output | Protection | Datasheet |
|---|---|---|---|---|---|
| Different options from 1 to 1024 pulses | 4, 5, 6, 8 or 10 mm | 37 mm | Push-Pull, TTL Line Driver, Open Collector | IP 54 |
Incremental measurement with optical principle 100 mm body diameter Hollow shaft options from 13 mm to 42 mm 1024 pulse resolution IP54 protection class
Incremental and extremely high precision measurement with optical measuring principle; 100 mm body diameter; hollow shaft
| Resolution | Hole Diameter | Body Diameter | Flange Type | Output | Protection | Datasheet |
|---|---|---|---|---|---|---|
| 1024 pulse | Options from 13 mm to 42 mm | 100 mm | Z type | Push-Pull, TTL Line Driver, Open Collector | IP 54 |
Non-contact measurement with magnetic principle Incremental output 58 mm body diameter 6 mm, 8 mm or 10 mm shaft options Resolution options between 1 pulse and 1024 pulses IP67 protection class
Incremental measurement with magnetic principle; 58 mm body diameter; design with shaft, IP67 protection class
| Resolution | Shaft Diameter | Body Diameter | Output | Protection | Datasheet |
|---|---|---|---|---|---|
| Options from 1 to 1024 pulses | 6, 8 or 10 mm | 58 mm | Push-Pull, TTL Line Driver, Open Collector | IP 67 |
Absolute measurement with magnetic principle 37 mm body diameter CANopen or analog output Shaft, semi hollow shaft and sleeved options 14 bit angular resolution 3000 RPM operating speed IP67 protection class
Absolute measurement with magnetic principle; 37 mm body diameter; CANopen or analog output; compact design
| Resolution | Shaft Diameter | Body Diameter | Output | Protection | Datasheet |
|---|---|---|---|---|---|
| 14 Bit | 6, 8 or 10 mm | 37 mm | CANopen or Analog | IP 67 |
Linear Measurement
Rotary Measurement
Inclination/ Tilt Measurement
Laser Distance Sensors
Pressure Measurement
Level Measurement
Temperature Measurement
Liquid Flow Measurement
Proximity Sensors
Joysticks
Dro, Display and Counters
Elevator Light Curtains
Speed and Motion Measurement
Counting Sensors
Seismic / Earthquake Sensors
Mechanical Plunger Switches
Accelerometers
Faucet Sensors
Seam Detector Sensors
Encoder Signal Conditioner and Optical Isolator
Couplings
Cable and Connectors