CMP 8270 Pressure Transmitteri || TRAFAG || Swiss Made
Thin film steel diaphragm
Stainless steel body
Options from 0 … 0.2 bar to 0 … 600 bar
±0.5% FS, ± 0.15% FS, ± 0.1% FS accuracy options
CANopen output
IP67 protection class
Pressure transmitter with steel diaphragm and temperature measurement in one device; CANopen output; small and durable design; very high accuracy value options
| Measuring Range | Output | Protection | Accuracy | Datasheet |
|---|---|---|---|---|
| 0 … 0.2 to 0 … 600 bar | CANopen |
IP67
|
±0.5% FS, ±0.15% FS,±0.1% FS |
- Thin film steel diaphragm
- Extra durable and very long lasting due to its superior sealing property as it is welded in one piece
- Stainless steel housing, resistant to very high pressures
- Extra resistance to vibrations and temperature changes
- Very suitable for use in engines
- Available in many different options from 0 … 2.5 bar to 0 … 2500 bar
- EMC and Reverse polarity protection
- IP65 Protection Class (IP67 or IP69k options)
- ±0.3% FS high sensitivity, ± 0.5% FS according to maximum pressure
- Different analog output signal options: 4-20 mA, 0.5-4.5 VDC ratiometric
- Mechanical connection options for pressure: G1/4″ male, R1/4″ male, G1/2″ male, 1/4 NPT” male, 1/2 NPT” male, M14x1.5 male, M18x1.5 male
| Brand |
Trafag |
|---|---|
| TECHNICAL FEATURES |
–> |
| Measuring principle |
Thin-film-on-steel |
| Measuring range |
0 … 0.2 to 0 … 600 bar |
| Output signal |
4 … 20 mA |
| Accuracy @25 °C |
± 0.5 % FS |
| Ambient temperature |
–40°C … +125°C |
| IP protection class |
IP65, IP67, IP69k |
| Mechanical connection |
G1/4" male |
- Engine manufacturing
- Railways
- Machine tools
- Hydraulics
- Process technology
- Test benches
Benzer Ürünler
Piezoresistive measuring principle Stainless steel housing (303) 10 Bar, 16 Bar, 0… -1 Bar, -1… 0 Bar Different options 4-20mA, 0-10 VDC or ratiometric output options ±1% F.S sensitivity IP65 protection class Compact construction
For air or non-corrosive gas applications
| Measuring Range | Output | Protection | Accuracy | Datasheet |
|---|---|---|---|---|
| 10 Bar, 16 Bar , 0…-1 Bar, -1…0 Bar | 4-20 mA, 0-10 VDC, Ratiometric | IP65 | ±%1 F.S |
Thin film steel diaphragm, flush membrane Stainless steel body Options from -0.5 ... 0.5 bar to 0 ... 100 bar ±0.5% FS sensitivity Different analog output options IP65, IP67 or IP68 protection class
Pressure transmitter with steel diaphragm and flush membrane; one-piece welded sealing body for high durability and resistance to ambient conditions; very small compact design; special smooth and flat flush membrane
| Measuring Range | Output | Protection | Accuracy | Datasheet |
|---|---|---|---|---|
| -0.5 ... 0.5 to 0 ... 100 bar | 4-20 mA, 0-10 VDC, 0-5 VDC, 1-6 VDC, 0.5-4.5 VDC ratiometric | IP65, IP67, IP68 | ±%0.5 FS |
Thin film steel diaphragm Stainless steel body Options from 0 ... 2,5 bar to 0 ... 2500 bar ±0.3% FS or ± 0.5% FS sensitivity 4 ... 20 mA or 0.5 ... 4.5 VDC ratiometric output options IP65, IP67 or IP69k protection class
Pressure transmitter with steel diaphragm; sesistant to high pressures up to 2500 bar, suitable for engines; superior sealing thanks to one-piece welding body; extra resistance to vibrations and temperature changes
| Measuring Range | Output | Protection | Accuracy | Datasheet |
|---|---|---|---|---|
| 0 ... 2.5 to 0 ... 2500 bar | 4-20 mA, 0.5-4.5 VDC ratiometric | IP65, IP67, IP69K | ±%0.3 FS, ±%0.5 FS |
-1…0~0.1bar…600bar pressure range Suitable for sanitary applications ±0.5%FS linearity 4-20 mA, 0-10V, 0-5V, 0.5-4.5V output IP65 protection class With cooling fan options, excellent performance for high temperature medium applications
Flush diaphragm; stainless steel body; high sensitivity; EMC and reverse polarity protection; for standard applications; high performance in high temperature applications up to 250°C with the option of cooling fan
100mbar…100bar pressure range Suitable for sanitary applications Suitable for 1.5" tri-clamp connection ±0.5%FS accuracy 4-20 mA, 0-10V etc. analog output options IP65 protection
BT10-211 flush pressure transmitter is applicable to food, beverage, pharmaceutical and biological engineering. Full metal flush-mounting isolation diaphragm is directly welded with process connection to ensure the precision connection between process connection and measuring diaphragm. Therefore, no additional sealing gaskets are required, and it ensures there are no measurement dead zones.| Pressure Range | Output | Protection | Accuracy | Datasheet |
|---|---|---|---|---|
| 0...100 mBar to 0...100 Bar | 4-20mA, 0-20mA, 0-10V, 1-6V, 0-5V, Ratiometric | IP 65 | ±0.5%FS |
Pressure switch with display -1 bar...10 bar pressure range ±2% FS accuracy Analog and transistor output Multiple measuring unit option
Pressure switch with ultra-low power consumption; multiple measurement unit option; analog and open collector output; high performance LCD display| Pressure Range | Output | Protection | Accuracy | Datasheet |
|---|---|---|---|---|
| -1bar ... 10bar | 4-20 mA, 1-5 VDC, PNP/NPN Open Collector |
IP40 |
±2% FS |
Linear Measurement
Rotary Measurement
Inclination/ Tilt Measurement
Laser Distance Sensors
Pressure Measurement
Level Measurement
Temperature Measurement
Liquid Flow Measurement
Proximity Sensors
Joysticks
Dro, Display and Counters
Elevator Light Curtains
Speed and Motion Measurement
Counting Sensors
Seismic / Earthquake Sensors
Mechanical Plunger Switches
Accelerometers
Faucet Sensors
Seam Detector Sensors
Encoder Signal Conditioner and Optical Isolator
Couplings
Cable and Connectors