TF1 Series || NOVOTECHNIK || Made in Germany
Non-contact inductive measurement
Resolution up to 10 µm
Reproducibility up to 5 µm
Analog or digital output options
IP67 protection class
Non-contact and inductive measuring principle; ability to measure at high speeds; 10 kHz refresh rate; infinite mechanical life; resistant to magnetic field; Very high sensitivity and resolution
Measuring Range | Output | Protection | Linearity | Datasheet |
---|---|---|---|---|
100 – 1000 mm | Analog(Curent or Voltage), SSI, IO-Link, CANopen | IP 67 | ≤±0.025 %FS | ![]() |
- Distance sensor with non-contact inductive principle
- Endless mechanical life due to completely non-contact measurement
- High-speed measurement: 10 kHz refresh rate
- Resolution values up to 10 µm, repeatability values up to 5 μm
- Analog (0-10V, 4-20 mA) or digital (SSI, IO-Link, CANopen) output options
- Not affected by magnetic field
- Shock and vibration resistant
- Not affected by temperature changes: <15 ppm / K temperature coefficient
- IP67 protection class
Brand |
Novotechnic |
---|---|
Stroke Values |
Different models between 100 mm and 1000 mm |
Resolution |
Analog: <400 mm:10µm, ≥400 mm:20µm |
Reproducibility |
Analog:<400 mm:10µm, ≥400 mm:20µm |
Absolute Linearity |
For Analog Output: <±%0.025 (min. ± 100 µm) |
Output Signals |
Analog Output: 0 – 10 VDC, 4 – 20 mA |
Overvoltage Protectionı |
42 VDC (has reverse polarity protection) |
Supply Voltage |
18…32 VDC |
Mounting |
Adjustable clamps (encluded in delivery) or slot nut |
Protection Class |
IP67 |
Operating Temperature |
-40°C … +85°C (CANopen: -40°C… +75°C) |
Life |
Mechanically unlimited |
Electrical Connection |
With cable or Socket |
- Presses
- Transfer Machines
- Metal Processing Machinery
- Plastic Injection Molding Machines
- Aluminum Injection Molding Machines
- Textile Machinery
- Marble Machines
- Packaging, Bottling and Food Machinery
- Testing Machines
- Robots and Automation
Benzer Ürünler
Non-contact inductive measuring principle High linearity: 0.1% 0-20 mA or 4-20 mA analog output options Extra robust housing Long life IP67 or IP50 protection class
Inductive principle with absolute and very precise measurement; unlimited mechanical life due to non-contact; extra durability thanks to fully enclosed body; linear scale which is not affected by temperature changes thanks to special coilMeasuring Range | Output | Protection | Linearity | Datasheet |
---|---|---|---|---|
10 mm | Analog (0-20 mA, 4-20 mA) | IP67 | ±0,1 %FS | ![]() |
Non-contact magnetostrictive measurement Plug-in Flange Rod type body Absolute operating Operating pressure up to 350 bar Analog output options High precision up to 0.04% IP67 or IP6K9K protection class
Non-contact and magnetostrictive measuring principle; internal connection to hydraulic or pneumatic cylinders; absolute operation, that is, not to lose position information in case of power failure
Measuring Range | Output | Protection | Linearity | Datasheet |
---|---|---|---|---|
50 - 2000 mm | Analog (0.5-4.5 V, 0.25-4.75 V, 0-10 V, 4-20 mA) | IP 67 / IP 69k | ≤±0,04 %FS | ![]() |
Precise potentiometric measurement Different measuring lengths from 75 mm to 900 mm Linearity up to 0.04% <0.01 mm high resolution Motion life of up to 100 million IP55 protection class
Precise and long-lasting position measurement; measurement at very high speeds due to the narrow bearing tolerance of the spindle and the special material-coated surface
Measuring Range | Output | Protection | Linearity | Datasheet |
---|---|---|---|---|
Different measuring lengths between 75 mm and 900 mm | Analog (potentiometric) | IP 55 | ±%0,04 | ![]() |
Precise potentiometric measurement Different measuring lengths from 10 mm to 100 mm Superior linearity up to 0.04% High resolution: <0.01 mm Motion life of up to 50 million Cable or socket versions IP67 protection class
Precise position measurement with extra durable housing; easy mounting with ball joint at both sides; extra long life thanks to the special membrane that compensates the pressure on the shaft; extra protection against vibrations and corrosion
Measuring Range | Output | Protection | Linearity | Datasheet |
---|---|---|---|---|
Different measuring lengths between 50 mm and 750 mm | Analog (potentiometric) | IP 67 | ±%0.04 | ![]() |
Magnetic measurement Incremental encoder output Contactless / non-friction system Measuring up to 20 meters Resolution options starting from 5µm IP67 protection class
High accuracy measurement with contactless magnetic system; Retention profile closed system, Protection against harsh environments with dust, humid and oil
Measuring Range | Output | Protection | Magnetic Tape | Resolution | Datasheet |
---|---|---|---|---|---|
Up to 20 meters | Push-Pull, TTL RS422 Line Driver | IP 67 | B5 | 5µm, 10µm, 25µm, 50µm, 62.5µm, 100µm, optional other resolutions | ![]() |
Contactless and frictionless operation Precise measurement up to 1000 mm Resolution options starting from 5 µm Push-Pull, TTL RS422 Line Driver output Articulated on both sides IP 65 Protection class
Magnetic principle-operated double side articulation linear encoder; infinite mechanical lifetime from contactless operation; high operating speed of up to 3 m/s
Maximum Measuring Length | Output | Protection | Resolution | Datasheet |
---|---|---|---|---|
Up to 1000 mm | Push-Pull, TTL RS422 Line Driver | IP 65 | 5 µm, 10 µm, 20 µm, 25 µm, 62.5 µm, 80µm, 100 µm | ![]() |