PTL 120 Salt Water Resistant Liquid Level Sensor || ATEK || Made in Türkiye
1.4462 (duplex), 316L or titanium body
High corrosion resistance, suitable for use in salt water
Different level measurements from 4 meters to 100 meters
4-20mA or 0-10 VDC analog output options, RS-485 Modbus output option
± 0.2% accuracy
IP68 protection class
Standard diaphragm; submersible level transmitters; durable for harsh conditions; dublex, 316L or titanium body; high precision; EMC and reverse polarity protection; Suitable for applications such as seawater, saltwater, grey water, waste water etc.
| Measuring Range | Membrane | O-Ring | Output | Protection | Accuracy | Datasheet |
|---|---|---|---|---|---|---|
|
Between 0-400 mbar and 0-25 bars
From 4 meters to 100 meters depth
|
Ceramic | NBR | 4-20 mA or 0-10 VDC | IP68 | %0,2 |
- Piezoresistive measurement principle
- Ceramic membrane
- 1.4462(dublex), 316L or titanium body
- Long-term stable operation
- EMC and Reverse Polarity protection
- 4-20 mA or 0-10 V analog output
- RS-485 Modbus output option
- Different level measuring between 4 meters and 100 meters
- IP68 protection class
- High quality
| Brand |
Atek |
|---|---|
| Measuring Principle |
Piezoresistive |
| Membrane |
Ceramic |
| O-Ring |
NBR |
| Measuring Range |
Selectable between 400 mbar and 25 Bar |
| Maximum Pressure |
% 200 FS |
| Accuracy |
% 0,3 |
| Supply Voltage |
12 … 30 VDC (for 0-10VDC output) |
| Output Signals |
4 … 20 mA (2-wire), 0 … 10 VDC (3-wire), RS485 Modbus |
| Mechanical Connection |
G1/2 male, G1/4 male, G1 1/2 male |
| Electrical Connection |
3 x 0,22 mm² PE Cable(Cable |
| Protection Class |
IP68 |
| Operating Temperature |
-20°C…+70°C |
| Storage Temperature |
-20°C…+70°C |
| Body Material |
1.4462 (dublex), 1.4404 (AISI 316L), titanium |
| Cable Material |
PE or PUR |
| EMC Protection |
Emission: EN/IEC 61000-6-3 |
- Seawater, saline water applications
- Grey water, waste water
- Wells
- Water Tanks
- River Level
- Lake Level
- Reservoirs
Benzer Ürünler
AISI 316L stainless steel body Different level measurements from 1 meters to 100 meters 4-20mA, 0-10 VDC or 0.5-4.5 VDC analog output options Suitable for oils and fuels ±%0,2 accuracy IP68 protection class Compact structure
Standard diaphragm; submersible level transmitters; durable for harsh conditions; 316L stainless steel body; high precision; EMC and reverse polarity protection, Suitable for applications such as oils and fuels| Measuring Range | Membrane | O-Ring | Output | Protection | Accuracy | Datasheet |
|---|---|---|---|---|---|---|
|
Between 0-100 mbar and 0-25 bars
From 1 meter to 100 meters depth |
AISI 316L | Viton (FKM) | 4-20 mA, 0-10 VDC, 0.5-4.5 VDC | IP68 | %0,2 |
Special design for textile sector Piezoresistive working principle 316L stainless steel housing Different models between 100 mBar and 600 mBar Analog 4-20mA / 0-10V and so on different outputs ±0.3% F.S accuracy IP65 protection class Compact construction
Special design for textile sector; stainless steel body; air isolated mounting; high sensitivity; EMC and reverse polarization protected; small and compact design| Measuring Range | Output | Protection | Accuracy | Body Diameter | Datasheet |
|---|---|---|---|---|---|
| Different models from 0...100mbar to 0...600mbar | 4-20 mA, 0-10 VDC, 0-20 mA, 1-6 VDC, 0-5 VDC, Ratiometric etc. | IP65 | ±%0,3 F.S | 23mm |
Min. material density sensed; 0.04g/cm³ 2xSPDT relay output SUS304/SUS316/SUS316L rod from 160mm to 6000mm Aluminum housing material LED status indicator IP65 protection class
| Min. material density sensed | Output | Connection | Protection | Operating Temp. | Datasheet |
|---|---|---|---|---|---|
| ≥0.04 g/cm³ | 2 x SPDT Relay | 1"PT | IP65 | -40...+150°C |
10-28VDC supply voltage NPN, PNP open collector output to energize relay or PLC Housing material of PC, PES, SUS304, SUS316 for applicable in water, oil, liquid solution, liquor, alcohol, organic solvent...etc. Over-current and reverse polarity protected LED status indicator IP67 protection class
The optical liquid level switch uses the principle of total reflection in a prism. When the sensor is surrounded by air, the angle of incidence is greater than the critical angle and thus total reflection occurs. Totally reflected light will be transmitted to the receiver. Conversely, when the sensor is surrounded by liquid, due to the refractive index of the liquid and the sensor tip material, almost all light will penetrate the front of the sensor. The receiver can detect and determine a light reflected or penetrated state, and determines the circuit output| Supply Voltage | Output | Connection | Protection | Operating Temp. | Datasheet |
|---|---|---|---|---|---|
| 10~28 Vdc | NPN or PNP Open Collector | PT, PF, NPT | IP67 | -10...+125°C |
12-30VDC supply voltage NPN or PNP output Suitable for Liquid, viscous medium, powder, granular medium Probe material PEEK surface roughness Ra <0.8 is with good wear resistance LED status indicator Compact and durable structure NEPSI ex-proof certificate IP67 protection
The sensor uses a frequency sweep method which emits an electrical signal at the sensing terminal to detect materials. Different mediums with different characteristics will generate different resonances, which will determine whether the sensor is covered by any materials, causing the switch output signal to light up. Suitable for single-point detection and protection of liquids, viscous mediums, powders, and granular mediums in tanks or pipelines.| Supply Voltage | Output | Connection | Protection | Operating Temp. | Datasheet |
|---|---|---|---|---|---|
| 12~30 Vdc | NPN or PNP | Standard type: 1/2”G Rear mounting type: 3/4”G | IP67 | Normal: -40...+80°C Ex-proof: -10...+70°C |