Non-contact inductive measuring principle
High linearity: 0.1%
0-20 mA or 4-20 mA analog output options
Extra robust housing
Long life
IP67 or IP50 protection class
Inductive principle with absolute and very precise measurement; unlimited mechanical life due to non-contact; extra durability thanks to fully enclosed body; linear scale which is not affected by temperature changes thanks to special coil
| Measuring Range | Output | Protection | Linearity | Datasheet |
|---|---|---|---|---|
| 10 mm |
Analog (0-20 mA, 4-20 mA)
|
IP67
|
±0,1 %FS |
- High linearity: 0.1%
- High accuracy and long life thanks to non-contact measurement
- Very reliable signal transmission thanks to standardized current output
- Fully sealed extra robust main body
- Operating principle unaffected by magnetic field changes
- Thanks to the special coil windings in it, it can work without being affected by the temperature changes in any way
| Brand |
Novotechnic |
|---|---|
| Stroke Values |
Mechanical: 12 mm |
| Linearity |
0,1 – 0,4 %FS |
| Repeatability |
< 2μm |
| Output Signals |
4-20 mA, 0-20 mA |
| Max Current Consumption |
50 mA |
| Protection Class |
IP50, IP67 |
| Operating Temperature |
-25°C … +70°C |
| Elektriksel bağlantı şekli |
Kablolu |
| Material |
Aluminum anodized body, stainless steel shaft |
| Mechanical Life |
100 million movements |
- Where short distances need to be measured with high precision
Benzer Ürünler
Non-contact magnetostrictive measurement Plug-in Flange Rod type body Absolute operating Operating pressure up to 350 bar Analog output options High precision up to 0.04% IP67 or IP6K9K protection class
Non-contact and magnetostrictive measuring principle; internal connection to hydraulic or pneumatic cylinders; absolute operation, that is, not to lose position information in case of power failure
| Measuring Range | Output | Protection | Linearity | Datasheet |
|---|---|---|---|---|
| 50 - 2000 mm | Analog (0.5-4.5 V, 0.25-4.75 V, 0-10 V, 4-20 mA) | IP 67 / IP 69k | ≤±0,04 %FS |
Precise potentiometric measurement Different measuring lengths from 75 mm to 900 mm Linearity up to 0.04% <0.01 mm high resolution Motion life of up to 100 million IP55 protection class
Precise and long-lasting position measurement; measurement at very high speeds due to the narrow bearing tolerance of the spindle and the special material-coated surface
| Measuring Range | Output | Protection | Linearity | Datasheet |
|---|---|---|---|---|
| Different measuring lengths between 75 mm and 900 mm | Analog (potentiometric) | IP 55 | ±%0,04 |
Magnetic measurement Incremental encoder output Contactless / non-friction system Extra slim profile structure Resolution options starting from 1µm IP67 protection class
High accuracy measurement with contactless magnetic system; Extra slim, retention profile closed system; Sealed protection against harsh environments with dust, humid and oil| Measuring Range | Output | Protection | Magnetic Tape | Resolution | Datasheet |
|---|---|---|---|---|---|
| Up to 3 meters |
Push-Pull, TTL RS422 Line Driver |
IP 67 | B2 | 1µm, 5µm, 10µm, 25 µm, 50µm, 62.5µm, 80µm, optional other resolutions |
Magnetic measurement Incremental encoder output Contactless / non-friction system Slim profile structure Measuring up to 20 meters Resolution options starting from 5µm IP67 protection class
High accuracy measurement with contactless magnetic system; Slim, retention profile closed system; Sealed protection against harsh environments with dust, humid and oil
| Measuring Range | Output | Protection | Magnetic Tape | Resolution | Datasheet |
|---|---|---|---|---|---|
| Up to 20 meters | Push-Pull, TTL RS422 Line Driver | IP 67 | B5 | 5µm, 10µm, 25µm, 50µm, 62.5µm, 100µm, optional other resolutions |
Magnetic measurement Small size Easy mounting Measure up to 100 meters Resolution from 1 μm to 100 μm Model with cable or socket Spiral or PUR cable option IP67 protection class
Reader sensor for contactless measurement on magnetic tape; internal tape slider against dust; extra durability against environmental factors such as moisture, oil, dust; model with cable or socket
| Measuring Range | Output | Protection | Magnetic Tape | Resolution | Datasheet |
|---|---|---|---|---|---|
| Up to 100 meters | Push-Pull, TTL RS422 Line Driver | IP 67 | B2, B5 | 1µm, 5 µm, 10µm, 25µm, 62.5µm, 80µm, 100µm, others on request |
Stroke options from 100 mm to 1000 mm Incremental optical system Slim body type Reference point at 50 mm intervals High resolution options up to 1 μm IP54 protection class 60 m/min operating speed
Optical precision measurement on glass surface; thin body with single or double gasket protection; 5 ball bearing system orientation; compact design, high accuracy| Measuring Range | Output Type | Protection | Resolution | Datasheet |
|---|---|---|---|---|
| Different measuring lengths from 100 mm to 1000 mm |
TTL RS-422
or Sinus |
IP 54 | 1µm, 5µm |
Linear Measurement
Rotary Measurement
Inclination/ Tilt Measurement
Laser Distance Sensors
Pressure Measurement
Level Measurement
Temperature Measurement
Liquid Flow Measurement
Proximity Sensors
Joysticks
Dro, Display and Counters
Elevator Light Curtains
Speed and Motion Measurement
Counting Sensors
Seismic / Earthquake Sensors
Mechanical Plunger Switches
Accelerometers
Faucet Sensors
Seam Detector Sensors
Encoder Signal Conditioner and Optical Isolator
Couplings
Cable and Connectors