AWP 508 Draw Wire Sensor || ATEK || Made in Türkiye
Different measuring lengths between 4000 mm and 8000 mm
±0.5% FS linearity
Potentiometric, 0-10 VDC, 4-20 mA or CANopen output options
IP54 (Optional IP67) protection class
Potentiometric measurement; robust stainless steel wire; suitable for long distance measurements; anodised aluminum body suitable for outdoor use; resistant to shocks and vibrations
- Different measuring lengths between 4000 mm and 8000 mm
- ±0.5% FS linearity
- Potentiometric, 0-10 VDC, 4-20 mA or CANopen output options
- IP54 (Optional IP67) protection class
- Compact design
- Easy installation
- Shock/Vibration resistant
- Aluminum anodized body
Brand |
Atek |
---|---|
Stroke (measuring) length |
Different measuring lengths between 4000 mm and 8000 mm |
Linearity |
±%0.5 FS |
Supply Voltage |
‘A‘ and ‘V’ models: 12…30 VDC |
Signal Output Type |
Potentiometric |
Measuring Type |
Potentiometric |
Resistance |
5 KΩ (standart), 10 KΩ |
Maximum Speed |
0.5 m/s |
Required Force |
10 N |
Operating Temperature |
-25°C … +85°C |
Materials |
Housing: Aluminum/steel /plastic |
Connection cable length |
3m (standart), 5m, 10m |
IP Protection Class |
IP54 (Opsiyonel P67) |
- Elevators
- Press machines
- Crane systems
- Wood processing machines
- Marble processing machines
- Storage positioning
- Dam protections
- Sluice gate control
- Air compressors
- Glass processing machines
- Lifting platforms
- Applications in medical technologies (operating table etc.)
- Forklifts
- Screw machines
- Paper machines
- Sewing machines
- Hydraulic machines
- Sheet metal machines
- Printing machines
- Horizontal control equipments
- Construction machines
- Industrial robots
- Injection machines
- X-Y axis displacement
- Liquid level measurements and position control
Benzer Ürünler
Non-contact inductive measuring principle High linearity: 0.1% 0-20 mA or 4-20 mA analog output options Extra robust housing Long life IP67 or IP50 protection class
Inductive principle with absolute and very precise measurement; unlimited mechanical life due to non-contact; extra durability thanks to fully enclosed body; linear scale which is not affected by temperature changes thanks to special coilMeasuring Range | Output | Protection | Linearity | Datasheet |
---|---|---|---|---|
10 mm | Analog (0-20 mA, 4-20 mA) | IP67 | ±0,1 %FS |
Precise potentiometric measurement Different measuring lengths from 10 mm to 100 mm High resolution: <0.05 mm ± 1% linearity Motion life of up to 10 million Springless and back spring model options IP65 protection class
Precise and cost-effective position measurement; compact design; high speed operation; optional push back spring
Measuring Range | Output | Protection | Linearity | Datasheet |
---|---|---|---|---|
Different measuring lengths between 10 mm and 100 mm | Analog (potentiometric) | IP 65 | ±%1 |
Magnetic measurement Incremental encoder output Contactless / non-friction system Measuring up to 20 meters Resolution options starting from 5µm IP67 protection class
High accuracy measurement with contactless magnetic system; Retention profile closed system, Protection against harsh environments with dust, humid and oil
Measuring Range | Output | Protection | Magnetic Tape | Resolution | Datasheet |
---|---|---|---|---|---|
Up to 20 meters | Push-Pull, TTL RS422 Line Driver | IP 67 | B5 | 5µm, 10µm, 25µm, 50µm, 62.5µm, 100µm, optional other resolutions |
Magnetic measurement Small size Easy mounting Measure up to 100 meters Resolution from 1 μm to 100 μm Model with cable or socket Spiral or PUR cable option IP67 protection class
Reader sensor for contactless measurement on magnetic tape; internal tape slider against dust; extra durability against environmental factors such as moisture, oil, dust; model with cable or socket
Measuring Range | Output | Protection | Magnetic Tape | Resolution | Datasheet |
---|---|---|---|---|---|
Up to 100 meters | Push-Pull, TTL RS422 Line Driver | IP 67 | B2, B5 | 1µm, 5 µm, 10µm, 25µm, 62.5µm, 80µm, 100µm, others on request |
Incremental optical system Different mesuring lengths from 50 mm to 1000 mm Selectable reference signal at every 10 mm 5µm resolution IP54 protection class 60 m/min traversing speed Compatible with Delem, Cybelec and ESA
Accurate measurement with optical principle; Gasket protected aluminum housing; LED status indicators; Compact design, High accuracy and repeatability
Measuring Range | Output Type | Protection | Resolution | Datasheet |
---|---|---|---|---|
Different measuring lengths from 50 mm to 1000 mm | TTL, Push Pull Line Driver, NPN | IP 54 | 5µm |
Stroke options from 100 mm to 1500 mm Incremental optical system Thick body type Reference point at 50 mm intervals High resolution up to 1 μm IP54 protection class 60 m/min operating speed
Optical precision measurement on glass surface; thick body with single gasket protection; 5 ball bearing system orientation; compact design, high accuracyMeasuring Range | Output Type | Protection | Resolution | Datasheet |
---|---|---|---|---|
Different measuring lengths from 100 mm to 1500 mm |
TTL RS-422
or Sinus |
IP 54 | 1µm, 5µm |