AWP 404 Draw Wire Sensor || ATEK || Made in Türkiye
Different measuring lengths between 1000 mm and 4000 mm
±0.5% FS linearity
Potentiometric, 0-10 VDC, 4-20 mA, CANopen or SSI output options
IP54 (Optional IP67) protection class
Potentiometric measurement; robust stainless steel wire; suitable for long distance measurements; anodised aluminum body suitable for outdoor use; resistant to shocks and vibrations
| Stroke (measuring) Length | Output | Protection | Linearity | Datasheet |
|---|---|---|---|---|
| Different measuring lengths between 1000 mm and 4000 mm | Potentiometric, 4-20 mA, 0-10 VDC, CANopen, SSI | IP54 (Optional IP67) | ±0,5% FS |
- Different measuring lengths between 1000 mm and 4000 mm
- ±0.5% FS linearity
- Potentiometric, 0-10 VDC, 4-20 mA, CANopen or SSI output options
- IP54 (Optional IP67) protection class
- Compact design
- Easy installation
- Shock/Vibration resistant
- Aluminum anodized body
| Brand |
Atek |
|---|---|
| Stroke (measuring) length |
Different measuring lengths between 1000 mm and 4000 mm |
| Linearity |
±%0.5 FS |
| Supply Voltage |
Current and Voltage output models: 12…30 VDC |
| Signal Output Type |
Potentiometric |
| Measuring Type |
Potentiometric |
| Resistance |
5 KΩ (standard), 10 KΩ |
| Maximum Speed |
0.5 m/s |
| Required Force |
5 N |
| Operating Temperature |
-25°C … +85°C |
| Materials |
Housing: Aluminum/steel /plastic |
| IP Protection Class |
IP54 (Optional IP67) |
- Elevators
- Press machines
- Crane systems
- Wood processing machines
- Marble processing machines
- Storage positioning
- Dam protections
- Sluice gate control
- Air compressors
- Glass processing machines
- Lifting platforms
- Applications in medical technologies (operating table etc.)
- Forklifts
- Screw machines
- Paper machines
- Sewing machines
- Hydraulic machines
- Sheet metal machines
- Printing machines
- Horizontal control equipments
- Construction machines
- Industrial robots
- Injection machines
- X-Y axis displacement
- Liquid level measurements and position control
Benzer Ürünler
Precise potentiometric measurement Different measuring lengths from 75 mm to 900 mm Linearity up to 0.04% <0.01 mm high resolution Motion life of up to 100 million IP55 protection class
Precise and long-lasting position measurement; measurement at very high speeds due to the narrow bearing tolerance of the spindle and the special material-coated surface
| Measuring Range | Output | Protection | Linearity | Datasheet |
|---|---|---|---|---|
| Different measuring lengths between 75 mm and 900 mm | Analog (potentiometric) | IP 55 | ±%0,04 |
Precise potentiometric measurement Different measuring lengths from 10 mm to 100 mm Superior linearity up to 0.04% High resolution: <0.01 mm Motion life of up to 50 million Cable or socket versions IP67 protection class
Precise position measurement with extra durable housing; easy mounting with ball joint at both sides; extra long life thanks to the special membrane that compensates the pressure on the shaft; extra protection against vibrations and corrosion
| Measuring Range | Output | Protection | Linearity | Datasheet |
|---|---|---|---|---|
| Different measuring lengths between 50 mm and 750 mm | Analog (potentiometric) | IP 67 | ±%0.04 |
Magnetic measurement Incremental encoder output Contactless / non-friction system Extra slim profile structure Resolution options starting from 1µm IP67 protection class
High accuracy measurement with contactless magnetic system; Extra slim, retention profile closed system; Sealed protection against harsh environments with dust, humid and oil| Measuring Range | Output | Protection | Magnetic Tape | Resolution | Datasheet |
|---|---|---|---|---|---|
| Up to 3 meters |
Push-Pull, TTL RS422 Line Driver |
IP 67 | B2 | 1µm, 5µm, 10µm, 25 µm, 50µm, 62.5µm, 80µm, optional other resolutions |
Incremental optical system Different mesuring lengths from 50 mm to 1000 mm Selectable reference signal at every 10 mm 5µm resolution IP54 protection class 60 m/min traversing speed Compatible with Delem, Cybelec and ESA
Accurate measurement with optical principle; Gasket protected aluminum housing; LED status indicators; Compact design, High accuracy and repeatability
| Measuring Range | Output Type | Protection | Resolution | Datasheet |
|---|---|---|---|---|
| Different measuring lengths from 50 mm to 1000 mm | TTL, Push Pull Line Driver, NPN | IP 54 | 5µm |
Stroke options from 100 mm to 1000 mm Incremental optical system Slim body type Reference point at 50 mm intervals High resolution options up to 1 μm IP54 protection class 60 m/min operating speed
Optical precision measurement on glass surface; thin body with single or double gasket protection; 5 ball bearing system orientation; compact design, high accuracy| Measuring Range | Output Type | Protection | Resolution | Datasheet |
|---|---|---|---|---|
| Different measuring lengths from 100 mm to 1000 mm |
TTL RS-422
or Sinus |
IP 54 | 1µm, 5µm |
Stroke options from 100 mm to 1500 mm Incremental optical system Thick body type Reference point at 50 mm intervals High resolution up to 1 μm IP54 protection class 60 m/min operating speed
Optical precision measurement on glass surface; thick body with single gasket protection; 5 ball bearing system orientation; compact design, high accuracy| Measuring Range | Output Type | Protection | Resolution | Datasheet |
|---|---|---|---|---|
| Different measuring lengths from 100 mm to 1500 mm |
TTL RS-422
or Sinus |
IP 54 | 1µm, 5µm |
Linear Measurement
Rotary Measurement
Inclination/ Tilt Measurement
Laser Distance Sensors
Pressure Measurement
Level Measurement
Temperature Measurement
Liquid Flow Measurement
Proximity Sensors
Joysticks
Dro, Display and Counters
Elevator Light Curtains
Speed and Motion Measurement
Counting Sensors
Seismic / Earthquake Sensors
Mechanical Plunger Switches
Accelerometers
Faucet Sensors
Seam Detector Sensors
Encoder Signal Conditioner and Optical Isolator
Couplings
Cable and Connectors