AWP 512 Draw Wire Sensor || ATEK || Made in Türkiye
Different stroke (measuring) lengths between 5000 mm and 12000 mm
±1% FS linearity
Potentiometric, 0-10 VDC, 4-20 mA or CANopen output options
IP54 (Optional IP67) protection class
Potentiometric measurement; robust stainless steel wire; suitable for long distance measurements; anodised aluminum body suitable for outdoor use; resistant to shocks and vibrations
- Different stroke (measuring) lengths between 5000 mm and 12000 mm
- ±1% FS linearity
- Potentiometric, 0-10 VDC, 4-20 mA or CANopen output options
- IP54 (Optional IP67) protection class
- Compact design
- Easy installation
- Shock/Vibration resistant
- Aluminum anodized body
Brand |
Atek |
---|---|
Stroke (measuring) length |
Different measuring lengths between 5000 mm and 12000 mm |
Linearity |
±%1 FS |
Supply Voltage |
‘A‘ and ‘V’ models: 12…30 VDC |
Signal Output Type |
Potentiometric |
Measuring Type |
Potentiometric |
Resistance |
5 KΩ (standart), 10 KΩ |
Maximum Speed |
0.5 m/s |
Required Force |
12 N |
Operating Temperature |
-25°C … +85°C |
Materials |
Housing: Aluminum/steel /plastic |
Connection cable length |
3m (standard), 5m, 10m |
IP Protection Class |
IP54 (Optional IP67) |
- Elevators
- Press machines
- Crane systems
- Wood processing machines
- Marble processing machines
- Storage positioning
- Dam protections
- Sluice gate control
- Air compressors
- Glass processing machines
- Lifting platforms
- Applications in medical technologies (operating table etc.)
- Forklifts
- Screw machines
- Paper machines
- Sewing machines
- Hydraulic machines
- Sheet metal machines
- Printing machines
- Horizontal control equipments
- Construction machines
- Industrial robots
- Injection machines
- X-Y axis displacement
- Liquid level measurements and position control
Benzer Ürünler
Precise potentiometric measurement Different measuring lengths from 10 mm to 100 mm Superior linearity up to 0.075% Motion life of up to 100 million Cable or socket version IP40 protection class
Precise and cost-effective position measurement; compact design; high speed operation; high repeatability value: 0.002 mm; push-back spring system
Measuring Range | Output | Protection | Linearity | Datasheet |
---|---|---|---|---|
Different measuring lengths between 10 mm and 100 mm | Analog (potentiometric) | IP 40 | ±%0,075 | ![]() |
Precise potentiometric measurement Different measuring lengths from 10 mm to 100 mm High resolution: <0.05 mm ± 1% linearity Motion life of up to 10 million Springless and back spring model options IP65 protection class
Precise and cost-effective position measurement; compact design; high speed operation; optional push back spring
Measuring Range | Output | Protection | Linearity | Datasheet |
---|---|---|---|---|
Different measuring lengths between 10 mm and 100 mm | Analog (potentiometric) | IP 65 | ±%1 | ![]() |
Magnetic, non-contact measurement Incremental encoder output Fixed Z reference point Different measuring lengths between 50 … 2000 mm Resolution options up to 5 µm IP67 protection LED indicator Compatible with Delem, Cybelec and ESA
High accuracy measurement with contactless magnetic system; special design for press brake machines; movable reference point; high tolerance to shock and vibrations; high protection against harsh environments with dust, humidty and oilMeasuring Range | Output | Protection | Magnetic Tape | Resolution | Datasheet |
---|---|---|---|---|---|
Up to 2000 mm |
Push-Pull, TTL RS422 Line Driver |
IP 67 | B2 | 5µm, 10µm, 25µm,50 µm, 62.5µm | ![]() |
Magnetic measurement Small size Easy mounting Measure up to 100 meters Resolution from 1 μm to 100 μm Model with cable or socket Spiral or PUR cable option IP67 protection class
Reader sensor for contactless measurement on magnetic tape; internal tape slider against dust; extra durability against environmental factors such as moisture, oil, dust; model with cable or socket
Measuring Range | Output | Protection | Magnetic Tape | Resolution | Datasheet |
---|---|---|---|---|---|
Up to 100 meters | Push-Pull, TTL RS422 Line Driver | IP 67 | B2, B5 | 1µm, 5 µm, 10µm, 25µm, 62.5µm, 80µm, 100µm, others on request | ![]() |
Stroke options from 100 mm to 1000 mm Incremental optical system Slim body type Reference point at 50 mm intervals High resolution options up to 1 μm IP54 protection class 60 m/min operating speed
Optical precision measurement on glass surface; thin body with single or double gasket protection; 5 ball bearing system orientation; compact design, high accuracyMeasuring Range | Output Type | Protection | Resolution | Datasheet |
---|---|---|---|---|
Different measuring lengths from 100 mm to 1000 mm |
TTL RS-422
or Sinus |
IP 54 | 1µm, 5µm | ![]() |
Stroke options from 100 mm to 3200 mm Incremental optical system Thick and long-distance body type Reference point at 50 mm intervals High resolution up to 1 μm IP54 protection class 60 m/min operating speed
Precise measurement on glass surface with optical principle; thick, long-distance body with single seal; 5 ball bearing system orientation; compact design, high accuracyMeasuring Range | Output Type | Protection | Resolution | Datasheet |
---|---|---|---|---|
Different measuring lengths from 100 mm to 3200 mm |
TTL RS-422
or Sinus |
IP 54 | 1µm, 5µm | ![]() |