Showing 157–168 of 322 results

Single axis 360° inclination measurement
Analog output options 0…5VDC, 0…10VDC or 4…20mA
2 x PNP open collector output type
±0.15⁰ sensitivity
IP64 protection class
Compact structure


– Programmable measuring range
– Both analog and transistor output at the same time and dual analog output support
– 0 point can be adjusted on the sensor

YHigh precision tilt measurement ±0.15°; transistor and analog output; compensated axial sensitivity; small and robust metal body

 Measurement Range Output Accuracy Protection Datasheet
 1 axis (X axis 0…360°) 0…5V / 0…10V / 4…20mA Analog Output 2 x PNP Open Collector (Transistor) ±0,15⁰ IP 64

Two axes 0 … 360⁰ angle and tilt measurement
Analog output options 0…5VDC, 0… 10VDC or 4… 20mA
PNP Open Collector output
±0.15⁰ sensitivity
IP64 protection class
Compact structure


– Programmable measuring range
– Both analog and transistor output at the same time
– 0 point can be adjusted on the sensor

High precision tilt measurement ±0.15°; compensated axial sensitivity; small and robust metal body

Measurement Range Output Accuracy Protection Datasheet
 1 axis (X axis 0…360°)  2 axis (X and Y axis ±0,90⁰) 0…5V / 0…10V / 4…20mA Analog Output PNP Open Collector (Transistor) ±0,15⁰ IP 64

±90⁰ dual-axis measuring range or 0-360 ° single-axis measuring range option
4-20 mA, 0-5V, 0-10V or CANopen signal output option
±0.2⁰ accuracy
IP67 protection class
Compact structure


Programmable measuring range (Via CANopen)
– Adjustable 0 point with external voltage

High precision angle measurement ±0.2°; compensated axial sensitivity; small and robust rectangle metal body

Measurement Range Output Accuracy Protection Datasheet
 1 axis (X axis 0…360°) 2 axis (X and Y axis ±0,90⁰) 0…5V / 0…10V / 4…20mA Analog Output CANopen ±0,2⁰ IP 67

Angle measurement up to 360⁰
4-20 mA, 0-5V, 0-10V or CANopen signal output option
±0.2⁰ accuracy
IP67 protection class
Compact structure


– Programmable measuring range (Via CANopen)
– Redundant output support
– Adjustable 0 point with external voltage

High precision tilt measurement ± 0.2°; compensated axial sensitivity; small and robust round metal body

Measurement Range Output Accuracy Protection Datasheet
> 1 axis (X axis 0…360°) 0…5V / 0…10V / 4…20mA Analog Output CANopen ±0,2⁰ IP 67

Integrated inclination sensor option for simultaneous length and inclination measurement
Different stroke (measuring) lengths up to 10000 mm (10 meters)
Selectable angle values between 0…360° or ±180° for inclination measurement
Analog or CANopen output
Programmable analog output option
IP67 protection class

Integrated inclination sensor option for simultaneous length and inclination measurement; programmable analog output; high accuracy; robust stainless steel wire; aluminum body; resistant to shocks and vibrations


Datasheet
 Stroke (measuring) Lengths Inclinometer Measuring Range Output Type Protection  Linearity Datasheet
Different measuring lengths up to 10000 mm (optional other strokes) Different angles between 0…360° and ±180°  Analog or CANopen IP67 ±%0,5 FS

Ceramic diaphragm
Stainless steel body
Options from 0 … 1 bar to 0 … 400 bar
±0.5% FS sensitivity
Different analog output options
IP65, IP67 or IP68 protection class
Economical and convenient solution
Datashee

Pressure transmitter with ceramic diaphragm; economical and durable solution; relative or absolute measurement option

Measuring Range Output Protection Accuracy Datasheet
0 … 1 to 0 … 400 bar 4-20 mA, 0-10 VDC, 0.5-4.5 VDC ratiometric, 0-5 VDC, 1-6 VDC
IP65, IP67, IP68
±%0.5 FS

Ceramic diaphragm
Stainless steel body
Options from 0 … 100 millibar to 0 … 40 bar
±0.3% FS sensitivity
Different analog output options
IP65, IP67 or IP68 protection class
Economical and convenient solution

Special series pressure transmitter for low pressures with ceramic diaphragm; economical and durable solution; relative or absolute measurement option

Measuring Range Output Protection Accuracy Datasheet
0 … 0.1 to 0 … 40 bar 4-20 mA, 0-10 VDC, 0.5-4.5 VDC ratiometric, 0-5 VDC, 1-6 VDC
IP65, IP67, IP68
±%0.3 FS

Marine certified
With ceramic diaphragm
Stainless steel or titanium body
Options from 0 … 0.1 bar to 0 … 250 bar
±0.3% FS sensitivity
4-20 mA analog output
IP65, IP67 or IP68 protection class
Economical and convenient solution

Pressure transmitter with ceramic diaphragm; marine certified; economic and durable; relative or absolute measurement option

Measuring Range Output Protection Accuracy Datasheet
0 … 0.1 to 0 … 250 bar 4-20 mA
IP65, IP67, IP68
±%0.3 FS

Thin film steel diaphragm
Stainless steel housing, high pressure resistant
Measurements from 0 … 2,5 bar to 0 … 600 bar
High sensitivity of ±0.3% and ±0.5% FS
Different analog output options
Wide temperature range up to 125°C
IP65, IP67 or IP68 protection class

Pressure transmitter with steel diaphragm; one-piece welded sealing body provides high durability and resistance to ambient conditions; very small compact design

 Measuring Range Output Protection Accuracy Datasheet
0 … 2.5 to 0 … 600 bar 4-20 mA, 0-10 VDC, 0.5-4.5 VDC ratiometric, 0-5 VDC, 1-6 VDC
IP65, IP67, IP68
±%0.5 FS, ±%0.3 FS

Thin film steel diaphragm
Stainless steel body
Options from 0 … 2,5 bar to 0 … 600 bar
±0.5% FS sensitivity
Different analog output options
Optional switching output
IP 65, IP67 or IP68 protection class

Pressure transmitter with steel diaphragm; High durability and unaffected by environmental conditions thanks to its one-piece welded, leak-proof body; very small compact design

Measuring Range Output Protection Accuracy Datasheet
0 … 2.5 to 0 … 600 bar 4-20 mA, 0-10 VDC, 0.5-4.5 VDC ratiometric, 0-5 VDC, 1-6 VDC, optional switching output
IP65, IP67, IP68
±%0.5 FS

Piezoresistive working principle
Stainless steel housing (1.4305)
Optional 316L or titanium housing
Different models between 100 mBar and 600 Bar
Analog 4-20mA / 0-10V, CANopen and MODBUS RS485 output options
±0.5% F.S or ± 0.3% F.S accuracy
IP65/IP67/IP68 protection class
Compact construction

Stainless steel body; high sensitivity; EMC and reverse polarization protected; small and compact design

Measuring Range Output Protection Accuracy Body Diameter Datasheet
Different models from 0…100mbar to 0…600bar  Different vacuum models from 0…-100mbar to 0…-1bar 4-20 mA, 0-10 VDC, 0-20 mA, 1-6 VDC, 0-5 VDC, Ratiometric, CANopen or MODBUS RS485 IP65/IP67/IP68 ±%0,5 F.S (ceramic), ±%0,3 F.S (silicon) 22mm

II 1G Ex ia IIC T4/T6 Ga
II 1D Ex ia IIIC T120°C / T85°C Da
ATEX ve IECEx
Ex Zones 0, 1, 2 (gas); 20, 21, 22 (dust)
Different models available from 100 mBar to 600 Bar
nalog output (4-20mA / 0-10V, etc.) or CANopen output
±%0,3 F.S accuracy
IP65 or IP67 protection
Compact design

ATEX certified for use in explosive atmospheres; high accuracy; protected against EMC and reverse polarity; small and compact design

 Measuring Range Output Protection Accuracy Body Diameter Datasheet
Different models from 0…100mbar to 0…600bar  Different vacuum models from 0…-100mbar to 0…-1bar 4-20 mA, 0-10 VDC, Ratiometric or CANopen IP65 or IP67 ±%0,3 F.S  22mm