Shop
Electrical angle options up to 360°
Spring and mechanical stop option for 120° (mechanical 124°)
0-10 VDC, 4-20 mA or ratiometric output options
12 bit resolution
8 mm hole diameter
IP54 protection class
Contactless, high-accuracy magnetic principle angular measurement; spring return and mechanical stop option; long life sensor
Non-contact angular measurement with magnetic principle
Electrical measuring angle 0 … 360 °
6 mm shaft diameter
Analog, SSI, SPI or incremental output options
Single or redundant output options
Analog:12 bit, SSI:12 bit, SPI:14 bit, Incremental:128, 256, 512, 1024 pulse resolution
IP54, IP65 or IP67 protection class
Datashee
Non-contact, high precision, rotary measurement with magnetic principle; integrated 6 mm shaft; very long life thanks to the non-contact measuring principle
| Measurement Range | Resolution | Linearity | Output | Protection | Supply Voltage | Datasheet |
|---|---|---|---|---|---|---|
| 360° electrical measurement angle |
12 bit
|
%±0.5
|
Analog, SSI, SPI, Incremental
|
IP54, IP65, IP67 | 5 VDC or 24 VDC |
Non-contact angular measurement with magnetic principle
Electrical range 720° up to 5760° in 360°-steps available
6 mm shaft diameter
Analog, SSI or SPI output options
16 bit resolution
Linearity up to 0,03%
IP54, IP65 or IP67 protection class
Non-contact, high precision, rotary measurement with magnetic principle; integrated 6 mm shaft; multiple turn options; not to lose position information in case of power outages; 16 bit resolution; very long life thanks to the non-contact measuring principle
Non-contact angular measurement with magnetic principle
Electrical measuring angle up to 360 °
Analog, SSI, SPI incremental, IO-link or CANopen output options
16 bit resolution
%0,5 linearity
IP67 or IP69K protection class
Non-contact, high precision, rotary measurement with magnetic principle; insensitive to shaking and impacts and endless mechanical life due to non-coupling, shaftless and mechanically non-contact measurement
Two axis (XY) tilt measurement
Adjustable ±90° measuring range
Model with relay or PNP Open Collector output
± 0.15⁰ sensitivity
IP64 protection class
Compact structure
– 4 different operating mode (N1/ N2 / N3 / N5)
– Adjustable set values in calibrated operating mode
– 0 point can be adjusted on the sensor
High precision tilt measurement ±0.1°; compensated axial sensitivity; small and robust metal body
| Measurement Range | Output | Accuracy | Protection | Datasheet |
|---|---|---|---|---|
| 2 axis (X and Y axis ±90°) | Relay PNP Open Collector (Transistor) | ±0,15⁰ | IP 64 |
Single axis 360° inclination measurement
Analog output options 0…5VDC, 0…10VDC or 4…20mA
2 x PNP open collector output type
±0.15⁰ sensitivity
IP64 protection class
Compact structure
– Programmable measuring range
– Both analog and transistor output at the same time and dual analog output support
– 0 point can be adjusted on the sensor
YHigh precision tilt measurement ±0.15°; transistor and analog output; compensated axial sensitivity; small and robust metal body
| Measurement Range | Output | Accuracy | Protection | Datasheet |
|---|---|---|---|---|
| 1 axis (X axis 0…360°) | 0…5V / 0…10V / 4…20mA Analog Output 2 x PNP Open Collector (Transistor) | ±0,15⁰ | IP 64 |
Two axes 0 … 360⁰ angle and tilt measurement
Analog output options 0…5VDC, 0… 10VDC or 4… 20mA
PNP Open Collector output
±0.15⁰ sensitivity
IP64 protection class
Compact structure
– Programmable measuring range
– Both analog and transistor output at the same time
– 0 point can be adjusted on the sensor
High precision tilt measurement ±0.15°; compensated axial sensitivity; small and robust metal body
| Measurement Range | Output | Accuracy | Protection | Datasheet |
|---|---|---|---|---|
| 1 axis (X axis 0…360°) 2 axis (X and Y axis ±0,90⁰) | 0…5V / 0…10V / 4…20mA Analog Output PNP Open Collector (Transistor) | ±0,15⁰ | IP 64 |
±90⁰ dual-axis measuring range or 0-360 ° single-axis measuring range option
4-20 mA, 0-5V, 0-10V or CANopen signal output option
±0.2⁰ accuracy
IP67 protection class
Compact structure
Programmable measuring range (Via CANopen)
– Adjustable 0 point with external voltage
High precision angle measurement ±0.2°; compensated axial sensitivity; small and robust rectangle metal body
| Measurement Range | Output | Accuracy | Protection | Datasheet |
|---|---|---|---|---|
| 1 axis (X axis 0…360°) 2 axis (X and Y axis ±0,90⁰) | 0…5V / 0…10V / 4…20mA Analog Output CANopen | ±0,2⁰ | IP 67 |
Angle measurement up to 360⁰
4-20 mA, 0-5V, 0-10V or CANopen signal output option
±0.2⁰ accuracy
IP67 protection class
Compact structure
– Programmable measuring range (Via CANopen)
– Redundant output support
– Adjustable 0 point with external voltage
High precision tilt measurement ± 0.2°; compensated axial sensitivity; small and robust round metal body
| Measurement Range | Output | Accuracy | Protection | Datasheet |
|---|---|---|---|---|
| > 1 axis (X axis 0…360°) | 0…5V / 0…10V / 4…20mA Analog Output CANopen | ±0,2⁰ | IP 67 |
Integrated inclination sensor option for simultaneous length and inclination measurement
Different stroke (measuring) lengths up to 10000 mm (10 meters)
Selectable angle values between 0…360° or ±180° for inclination measurement
Analog or CANopen output
Programmable analog output option
IP67 protection class
Integrated inclination sensor option for simultaneous length and inclination measurement; programmable analog output; high accuracy; robust stainless steel wire; aluminum body; resistant to shocks and vibrations
Ceramic diaphragm
Stainless steel body
Options from 0 … 1 bar to 0 … 400 bar
±0.5% FS sensitivity
Different analog output options
IP65, IP67 or IP68 protection class
Economical and convenient solution
Datashee
Pressure transmitter with ceramic diaphragm; economical and durable solution; relative or absolute measurement option
| Measuring Range | Output | Protection | Accuracy | Datasheet |
|---|---|---|---|---|
| 0 … 1 to 0 … 400 bar | 4-20 mA, 0-10 VDC, 0.5-4.5 VDC ratiometric, 0-5 VDC, 1-6 VDC |
IP65, IP67, IP68
|
±%0.5 FS |
Ceramic diaphragm
Stainless steel body
Options from 0 … 100 millibar to 0 … 40 bar
±0.3% FS sensitivity
Different analog output options
IP65, IP67 or IP68 protection class
Economical and convenient solution
Special series pressure transmitter for low pressures with ceramic diaphragm; economical and durable solution; relative or absolute measurement option
| Measuring Range | Output | Protection | Accuracy | Datasheet |
|---|---|---|---|---|
| 0 … 0.1 to 0 … 40 bar | 4-20 mA, 0-10 VDC, 0.5-4.5 VDC ratiometric, 0-5 VDC, 1-6 VDC |
IP65, IP67, IP68
|
±%0.3 FS |
Linear Measurement
Rotary Measurement
Inclination/ Tilt Measurement
Laser Distance Sensors
Pressure Measurement
Level Measurement
Temperature Measurement
Liquid Flow Measurement
Proximity Sensors
Joysticks
Dro, Display and Counters
Elevator Light Curtains
Speed and Motion Measurement
Counting Sensors
Seismic / Earthquake Sensors
Mechanical Plunger Switches
Accelerometers
Faucet Sensors
Seam Detector Sensors
Encoder Signal Conditioner and Optical Isolator
Couplings
Cable and Connectors