SEP 160 Level Switch with Propeller || Fiama ||
- Plastic body
- Waterproof construction for outdoor work
- Inox steel shaft is mounted on air-tight ball bearings.
- Technopolymer impeller
- 2” 1/2 inch threaded head or 6-hole plate for mounting available on request.
- 16, 30, 50, 70, 100 cm long propeller holder shaft; It is the working part inside the tank.
| Brand |
Fiama |
|---|---|
| Case |
Plastic |
| Protection Class |
P65 |
| Electrical Contacts |
6A 250Vac, 3A 250Vdc |
| Operating Temperature |
-10°…+60° C |
| Absorbtion |
3 VA |
| Power Consumption |
Maks. 4W |
| Shaft Length |
15, 30, 50, 70, 100 cm |
| Electromagnetic Compatibility |
2014/30/UE |
The level controls with propeller SEP are used for the control of level in tanks that contain powders or granular material
|
DATASHEET
|
|
|---|---|
Benzer Ürünler
AISI 316L stainless steel body Different level measurements from 1 meter to 100 meters 4-20mA or 0-10 VDC analog output options RS-485 Modbus output option ±0.2% accuracy Oil- and fuel-resistant model option IP68 protection class Compact structure
Standard diaphragm; submersible level transmitters; durable for harsh conditions; stainless steel body; high precision; EMC and reverse polarity protection; Suitable for use with oils and fuels, wells, water tanks, lake or river level monitoring, reservoirs, wastewater, and greywater.Suitable for mineral oils Alarm delay time between 0-40 seconds can be selected at the ordering stage 40 Bar pressure resistance Sink (NPN) or source (PNP) output type High accuracy and stability IP67 protection class
Suitable for level measurement in mineral oils, sink (NPN) or source (PNP) output, selectable alarm delay time between 0-40 secondsSpecial design for textile sector Piezoresistive working principle 316L stainless steel housing Different models between 100 mBar and 600 mBar Analog 4-20mA / 0-10V and so on different outputs ±0.3% F.S accuracy IP65 protection class Compact construction
Special design for textile sector; stainless steel body; air isolated mounting; high sensitivity; EMC and reverse polarization protected; small and compact design
| Measuring Range | Output | Protection | Accuracy | Body Diameter | Datasheet |
|---|---|---|---|---|---|
| Different models from 0...100mbar to 0...600mbar | 4-20 mA, 0-10 VDC, 0-20 mA, 1-6 VDC, 0-5 VDC, Ratiometric etc. | IP65 | ±%0,3 F.S | 23mm |
Ultrasonic working principle 0.5 - 9 meters measuring distance 4-20mA, 0-10V, 0-20 mA analog output options available CANopen, RS485, RS232 serial communication options IP65 or IP67 protection class Robust housing
Non-contact, level and volume measurement of liquid and solid materials in open and closed tanks, measuring range can be calibrated from the menu| Measuring Range | Output | Taper Angle | Accuracy | Protection | Datasheet |
|---|---|---|---|---|---|
| 0.5 - 9 meters | 4-20 mA, 0-20 mA, 0-10V, CANopen, RS-232, RS-485, 2xPNP Open Collector | 30° | %0,2 FS | IP65 or IP67 |
Non-contact liquid and solid level measurement High frequency 80GHz, more focus Accuracy ±2 mm(liquid), ±5 mm(solid) Measuring range up to 30m Small emitting angle ±3.5° 4-20 mA+HART+RS485 output G2 connection Exproof IP67 protection
Ideal for for continuous level measurement in liquid, simple solid and open water applications. Exproof and suitable for use in explosive environments.| Measuring Range | Output | Protection | Accuracy | Datasheet |
|---|---|---|---|---|
| Up to 30 meters (liquid and solid) | 4-20 mA+HART+RS485 | IP67 | ±2 mm (liquid) ±5 mm (solid) |
10-28VDC supply voltage NPN, PNP open collector output to energize relay or PLC Housing material of PC, PES, SUS304, SUS316 for applicable in water, oil, liquid solution, liquor, alcohol, organic solvent...etc. Over-current and reverse polarity protected LED status indicator IP67 protection class
The optical liquid level switch uses the principle of total reflection in a prism. When the sensor is surrounded by air, the angle of incidence is greater than the critical angle and thus total reflection occurs. Totally reflected light will be transmitted to the receiver. Conversely, when the sensor is surrounded by liquid, due to the refractive index of the liquid and the sensor tip material, almost all light will penetrate the front of the sensor. The receiver can detect and determine a light reflected or penetrated state, and determines the circuit output| Supply Voltage | Output | Connection | Protection | Operating Temp. | Datasheet |
|---|---|---|---|---|---|
| 10~28 Vdc | NPN or PNP Open Collector | PT, PF, NPT | IP67 | -10...+125°C |
Linear Measurement
Rotary Measurement
Inclination/ Tilt Measurement
Laser Distance Sensors
Pressure Measurement
Level Measurement
Temperature Measurement
Liquid Flow Measurement
Proximity Sensors
Joysticks
Dro, Display and Counters
Elevator Light Curtains
Speed and Motion Measurement
Counting Sensors
Seismic / Earthquake Sensors
Mechanical Plunger Switches
Accelerometers
Faucet Sensors
Seam Detector Sensors
Encoder Signal Conditioner and Optical Isolator
Couplings
Cable and Connectors