SEM 150 Level Switch with Propeller || Fiama ||
- Accurate protection against dust from tank
- Die-cast aluminium case: waterproof for working also in open air
- Stainless steel shaft mounted on ball bearings
- Propeller in aluminium or on request in stainless steel
- Mounting with a 6-bore flange or on request with a threaded hub of 1”1/2 inch GAS
- Standard lengths of the shaft (with propeller holder) are cm 15, 30, 50, 70, 100: it is the part that works inside the tank
| Brand |
Fiama |
|---|---|
| Case |
Aluminum |
| Protection Class |
IP65 |
| Electrical Contacts |
6A 250Vac, 3A 250Vdc |
| Operating Temperature |
-10°…+60° C/td> |
| Power Supply |
24 115 230 Vac ±10% 50/60 Hz 24 Vdc ±10 % |
| Absorbtion |
3 VA |
| Shaft Length |
15, 30, 50, 70, 100 cm |
| Electromagnetic Compatibility |
2014/30/UE |
The level controls with propeller SEM are used for the control of level in tanks that contain powders or granular material
|
DATASHEET
|
|
|---|---|
Benzer Ürünler
Various immersion length options from 75 mm to 500 mm Wide range of customizable features (mechanical connection type, electrical connection, material type, etc.) SPDT or SPST relay output Maximum reliability thanks to high-quality reed contacts Fast and easy installation
Liquid level control with float, SPDT or SPST relay output, and a wide range of options for various applications| Immersion Length | Output Type | Process Connection | Protection | Datasheet |
|---|---|---|---|---|
| Different options from 75 to 500mm | SPDT or SPST relay | G1/2, G1/4, M20x1.5, M14x1, G1” | IP65 |
Suitable for mineral oils Alarm delay time between 0-40 seconds can be selected at the ordering stage 40 Bar pressure resistance Sink (NPN) or source (PNP) output type High accuracy and stability IP67 protection class
Suitable for level measurement in mineral oils, sink (NPN) or source (PNP) output, selectable alarm delay time between 0-40 secondsSuitable for temperatures up to +200ºC 1 RPM rotation speed Material density of 0.3 g/cm3 Switch output 24VDC supply IP65 protection class
Economic solution; gasket design prevents dust accumulation; also suitable for high temperature applications| Operating Temperature | Output | Protection | Datasheet |
|---|---|---|---|
| -40ºC ... +200ºC | Switch | IP65 |
Non-contact liquid level measurement High frequency 80GHz, more focus Accuracy ±2 mm(liquid) Measuring range up to 30m Easy Setup via Bluetooth Small emitting angle ±3.5° 4-20mA + RS485 output G1,5 connection IP67 protection
Ideal for non-contact liquid level measurement in simple applications. It is especially suitable for open channel applications. It can also be used in some liquid tanks and containers.With Bluetooth feature, it allows level reading and adjustment without approaching the tank or hazardous area.| Measuring Range | Output | Protection | Accuracy | Datasheet |
|---|---|---|---|---|
| Up to 30 meters (liquid) | 4-20 mA + RS485 | IP67 | ±2 mm |
Non-contact liquid level measurement High frequency 80GHz, more focus Accuracy ±2 mm(liquid) Measuring range up to 30m Easy Setup via Bluetooth< Small emitting angle ±3.5° 4-20 mA+HART+RS485 output G1,5 connection IP67 protection
Ideal for non-contact liquid level measurement in simple applications. It is especially suitable for open channel applications. It can also be used in some liquid tanks and containers. With Bluetooth feature, it allows level reading and adjustment without approaching the tank or hazardous area.| Measuring Range | Output | Protection | Accuracy | Datasheet |
|---|---|---|---|---|
| Up to 30 meters (liquid) | 4-20 mA+HART+RS485 | IP67 | ±2 mm |
10-28VDC supply voltage NPN, PNP open collector output to energize relay or PLC Housing material of PC, PES, SUS304, SUS316 for applicable in water, oil, liquid solution, liquor, alcohol, organic solvent...etc. Over-current and reverse polarity protected LED status indicator IP67 protection class
The optical liquid level switch uses the principle of total reflection in a prism. When the sensor is surrounded by air, the angle of incidence is greater than the critical angle and thus total reflection occurs. Totally reflected light will be transmitted to the receiver. Conversely, when the sensor is surrounded by liquid, due to the refractive index of the liquid and the sensor tip material, almost all light will penetrate the front of the sensor. The receiver can detect and determine a light reflected or penetrated state, and determines the circuit output| Supply Voltage | Output | Connection | Protection | Operating Temp. | Datasheet |
|---|---|---|---|---|---|
| 10~28 Vdc | NPN or PNP Open Collector | PT, PF, NPT | IP67 | -10...+125°C |
Linear Measurement
Rotary Measurement
Inclination/ Tilt Measurement
Laser Distance Sensors
Pressure Measurement
Level Measurement
Temperature Measurement
Liquid Flow Measurement
Proximity Sensors
Joysticks
Dro, Display and Counters
Elevator Light Curtains
Speed and Motion Measurement
Counting Sensors
Seismic / Earthquake Sensors
Mechanical Plunger Switches
Accelerometers
Faucet Sensors
Seam Detector Sensors
Encoder Signal Conditioner and Optical Isolator
Couplings
Cable and Connectors