NAT 8252 Pressure Transmitter || TRAFAG || Swiss Made
Thin film steel diaphragm
Stainless steel body
Options from 0 … 2,5 bar to 0 … 600 bar
±0.5% FS sensitivity
Different analog output options
Optional switching output
IP 65, IP67 or IP68 protection class
Pressure transmitter with steel diaphragm; High durability and unaffected by environmental conditions thanks to its one-piece welded, leak-proof body; very small compact design
| Measuring Range | Output | Protection | Accuracy | Datasheet |
|---|---|---|---|---|
| 0 … 2.5 to 0 … 600 bar | 4-20 mA, 0-10 VDC, 0.5-4.5 VDC ratiometric, 0-5 VDC, 1-6 VDC, optional switching output |
IP65, IP67, IP68
|
±%0.5 FS |
- Thin film steel diaphragm
- Extra durable and very long lasting due to its superior sealing property as it is welded in one piece
- Stainless steel housing, high pressure resistant
- Available in many different options from 0 … 2,5 bar to 0 … 600 bar
- ±0.5% FS high precision
- EMC and Reverse polarity protection
- IP 65 Protection Class (Wired IP67 / IP68)
- Different analog output signal options: 4-20 mA, 0.5-4.5 VDC, 0-5 VDC, 1-5 VDC, 1-6 VDC, 0-10 VDC, 0.1-10.1 VDC
- Optional switching output: 1 or 2 PNP transistors
- Mechanical connection options for pressure: G1/4″ male, 1/4″ NPT male, 1/8″ NPT male, R1/4″ male, R1/8″ male, 7/16″-20UNF male, 7/16″-20UNF female, M10x1 male, M12x1.5 male, M14x1.5 male
| Brand |
Trafag |
|---|---|
| TECHNICAL FEATURES |
–> |
| Measuring principle |
Thin-film-on-stee |
| Measuring range |
0 … 2.5 to 0 … 600 bar |
| Output signal |
4 … 20 mA |
| Accuracy @25 °C |
± 0.5 %FS |
| Ambient temperature |
–40°C … +125°C |
| IP Protection Class |
IP65 (with cable IP67 / IP68) |
| Mechanical connection |
G1/4" male |
- Manufacturing Machines
- All hydraulic machines
- HVAC machines (Heating, air conditioning, ventilation units)
- Cooling units
- Water treatment machines
Benzer Ürünler
Ceramic diaphragm Stainless steel body Options from 0 ... 100 millibar to 0 ... 40 bar ±0.3% FS sensitivity Different analog output options IP65, IP67 or IP68 protection class Economical and convenient solution
Special series pressure transmitter for low pressures with ceramic diaphragm; economical and durable solution; relative or absolute measurement option
| Measuring Range | Output | Protection | Accuracy | Datasheet |
|---|---|---|---|---|
| 0 ... 0.1 to 0 ... 40 bar | 4-20 mA, 0-10 VDC, 0.5-4.5 VDC ratiometric, 0-5 VDC, 1-6 VDC | IP65, IP67, IP68 | ±%0.3 FS |
Piezoresistive measuring principle Stainless steel housing (303) 10 Bar, 16 Bar, 0… -1 Bar, -1… 0 Bar Different options 4-20mA, 0-10 VDC or ratiometric output options ±1% F.S sensitivity IP65 protection class Compact construction
For air or non-corrosive gas applications
| Measuring Range | Output | Protection | Accuracy | Datasheet |
|---|---|---|---|---|
| 10 Bar, 16 Bar , 0…-1 Bar, -1…0 Bar | 4-20 mA, 0-10 VDC, Ratiometric | IP65 | ±%1 F.S |
Thin film steel diaphragm, flush membrane Stainless steel body Options from -0.5 ... 0.5 bar to 0 ... 100 bar ±0.5% FS sensitivity Different analog output options IP65, IP67 or IP68 protection class
Pressure transmitter with steel diaphragm and flush membrane; one-piece welded sealing body for high durability and resistance to ambient conditions; very small compact design; special smooth and flat flush membrane
| Measuring Range | Output | Protection | Accuracy | Datasheet |
|---|---|---|---|---|
| -0.5 ... 0.5 to 0 ... 100 bar | 4-20 mA, 0-10 VDC, 0-5 VDC, 1-6 VDC, 0.5-4.5 VDC ratiometric | IP65, IP67, IP68 | ±%0.5 FS |
Thin film steel diaphragm Stainless steel body Options from 0 ... 0.2 bar to 0 ... 600 bar ±0.5% FS, ± 0.15% FS, ± 0.1% FS accuracy options CANopen output IP67 protection class
Pressure transmitter with steel diaphragm and temperature measurement in one device; CANopen output; small and durable design; very high accuracy value options
| Measuring Range | Output | Protection | Accuracy | Datasheet |
|---|---|---|---|---|
| 0 ... 0.2 to 0 ... 600 bar | CANopen | IP67 | ±0.5% FS, ±0.15% FS,±0.1% FS |
-1…0~0.1bar…600bar pressure range Suitable for sanitary applications ±0.5%FS linearity 4-20 mA, 0-10V, 0-5V, 0.5-4.5V output IP65 protection class With cooling fan options, excellent performance for high temperature medium applications
Flush diaphragm; stainless steel body; high sensitivity; EMC and reverse polarity protection; for standard applications; high performance in high temperature applications up to 250°C with the option of cooling fan
Pressure switch with display -1 bar...10 bar pressure range ±2% FS accuracy Analog and transistor output Multiple measuring unit option
Pressure switch with ultra-low power consumption; multiple measurement unit option; analog and open collector output; high performance LCD display| Pressure Range | Output | Protection | Accuracy | Datasheet |
|---|---|---|---|---|
| -1bar ... 10bar | 4-20 mA, 1-5 VDC, PNP/NPN Open Collector |
IP40 |
±2% FS |
Linear Measurement
Rotary Measurement
Inclination/ Tilt Measurement
Laser Distance Sensors
Pressure Measurement
Level Measurement
Temperature Measurement
Liquid Flow Measurement
Proximity Sensors
Joysticks
Dro, Display and Counters
Elevator Light Curtains
Speed and Motion Measurement
Counting Sensors
Seismic / Earthquake Sensors
Mechanical Plunger Switches
Accelerometers
Faucet Sensors
Seam Detector Sensors
Encoder Signal Conditioner and Optical Isolator
Couplings
Cable and Connectors