Showing 13–24 of 34 results

Piezorezistif ölçüm prensibi
Paslanmaz çelik veya titanyum gövde
0 … 0,1 bar’dan 0 … 25 bar’a kadar seçenekler
±%0,1 veya ±%0,5 FS hassasiyet
4-20mA veya 0-10VDC analog çıkış
IP68 koruma sınıfı

Piezorezistif ölçüm prensibi; O-ringlerle temas eden ortam yok; şimşek çarpmalarına karşı korumalı; PUR veya FEP kablo seçenekleri

 Maksimum Ölçüm Basıncı Çıkış Koruma Hassasiyet Datasheet
0,1 bar’dan 25 bar’a kadar 4-20 mA, 0-10 VDC
IP68
±%0.1 FS, ±%0.5 FS

Thin film steel diaphragm, flush membrane
Stainless steel body
Options from -0.5 … 0.5 bar to 0 … 100 bar
±0.5% FS sensitivity
Different analog output options
IP65, IP67 or IP68 protection class

Pressure transmitter with steel diaphragm and flush membrane; one-piece welded sealing body for high durability and resistance to ambient conditions; very small compact design; special smooth and flat flush membrane

Measuring Range Output Protection Accuracy Datasheet
-0.5 … 0.5 to 0 … 100 bar 4-20 mA, 0-10 VDC, 0-5 VDC, 1-6 VDC, 0.5-4.5 VDC ratiometric
IP65, IP67, IP68
±%0.5 FS

Suitable for use in explosive environments
Atex and IECEx certificate
Thin film steel diaphragm
Stainless steel body
Options from 0 … 400 millibar to 0 … 2000 bar
±0.3% FS or ±0.5% FS sensitivity
4-20 mA analog output
IP65 or IP67 protection class

Pressure transmitter with steel diaphragm; Ex-Proof certified, suitable for use in explosive environments; resistant to high pressures up to 2000 bar; superior sealing thanks to one piece welding body

Measuring Range Output Protection Accuracy Datasheet
0 … 0.4 to 0 … 2000 bar 4-20 mA
IP65, IP67
±%0.3 FS, ±%0.5 FS

Thick film ceramic diaphragm
Stainless steel body
Options from 0 … 0.1 bar to 0 … 6 bar
±0.3% FS accuracy
4-20 mA analog output
IP68 protection class

Submersible pressure transmitter with ceramic diaphragm; suitable for pressure measurement of dense and viscous substances; protected against lightning strikes; PUR or PE cable options

Measuring Range Output Protection Accuracy Datasheet
0 … 0.1 to 0 … 6.0 bar 4-20 mA
IP68
±%0.3 FS

Suitable for use in explosive environments
Atex certified
Versions with frontal or with flush diaphragm
Options from 0 … 0.1 bar to 0 … 1000 bar
±0.1% FS, ±0.25% FS or ±0.5% FS sensitivity
4-20 mA analog output
IP68 protection class

Piezoresistive submersible pressure transmitter; Ex-Proof certified, explosion-proof; Stainlees steel or titanium body; PUR or FEP cable options

Measuring Range Output Protection Accuracy Datasheet
0 … 0.1 to 0 … 1000 bar 4-20 mA
IP68
±%0.1 FS, ±%0.25 FS, ±%0.5 FS

Suitable for use in explosive environments
Atex and IECEx certified
Versions with frontal or with flush diaphragm
Options from 0 … 0.1 bar to 0 … 1000 bar
±0.1% FS or ±0.25% FS accuracy
4-20 mA analog output
IP68 protection class

Piezoresistive submersible pressure transmitter; Ex-Proof certified, explosion-proof; Versions with frontal or with flush diaphragm; DIN43650 connector, M12 connector, PUR or FEP cable options

Measuring Range Output Protection Accuracy Datasheet
0 … 0.1 to 0 … 1000 bar 4-20 mA
IP68
±%0.1 FS, ±%0.25 FS

Suitable for use in explosive environments
Atex certified
Stainless steel or titanium body
Options from 0 … 0.1 bar to 0 … 25 bar
±0.1% FS, ±0.25% FS or ±0.5% FS sensitivity
4-20 mA analog output
IP68 protection class

Piezoresistive submersible pressure transmitter; Ex-Proof certified, explosion-proof; Stainlees steel or titanium body PUR or FEP cable options

Measuring Range Output Protection Accuracy Datasheet
0 … 0.1 to 0 … 25 bar 4-20 mA
IP68
±%0.1 FS, ±%0.25 FS, ±%0.5 FS

Suitable for use in explosive environments
Atex and  IECEx certified
Stainless steel or titanium body
Options from 0 … 0.1 bar to 0 … 25 bar
±0.1% FS, ±0.25% FS or ±0.5% FS sensitivity
4-20 mA analog output
IP68 protection class

Piezoresistive submersible pressure transmitter; Ex-Proof certified, explosion-proof; Stainlees steel or titanium body; PUR or FEP cable options

Measuring Range Output Protection Accuracy Datasheet
0 … 0.1 to 0 … 25 bar 4-20 mA
IP68
±%0.1 FS, ±%0.25 FS

Thin film steel diaphragm
Stainless steel body
Options from 0 … 2,5 bar to 0 … 600 bar
±0.3% FS, ± 0.15% FS, ± 0.1% FS accuracy
Different analog output options
IP 65 or IP67 protection class

Pressure transmitter with steel diaphragm ; high sensitivity values; one-piece welded sealing body for high durability and resistance to ambient conditions; smallest compact design; extra high pressure resistance

Measuring Range Output Protection Accuracy Datasheet
0 … 2.5 to 0 … 600 bar 4-20 mA, 0-5 VDC, 0-10 VDC, 1-6 VDC, 0.5-4.5 VDC ratiometric
IP65, IP67
±%0.3 FS, ±%0.15 FS, ±%0.1 FS

Thin film steel diaphragm
Stainless steel body
Options from 0 … 2,5 bar to 0 … 2500 bar
±0.3% FS or ± 0.5% FS sensitivity
4 … 20 mA or 0.5 … 4.5 VDC ratiometric output options
IP65, IP67 or IP69k protection class

Pressure transmitter with steel diaphragm; sesistant to high pressures up to 2500 bar, suitable for engines; superior sealing thanks to one-piece welding body; extra resistance to vibrations and temperature changes

Measuring Range Output Protection Accuracy Datasheet
0 … 2.5 to 0 … 2500 bar 4-20 mA, 0.5-4.5 VDC ratiometric
IP65, IP67, IP69K
±%0.3 FS, ±%0.5 FS

Thin film steel diaphragm
Stainless steel body
Options from 0 … 0.2 bar to 0 … 600 bar
±0.5% FS, ± 0.15% FS, ± 0.1% FS accuracy options
CANopen output
IP67 protection class

Pressure transmitter with steel diaphragm and temperature measurement in one device; CANopen output; small and durable design; very high accuracy value options

Measuring Range Output Protection Accuracy Datasheet
0 … 0.2 to 0 … 600 bar CANopen
 IP67
±0.5% FS, ±0.15% FS,±0.1% FS 

-1…0~0.1bar…600bar pressure range
Suitable for sanitary applications
±0.5%FS linearity
4-20 mA, 0-10V, 0-5V, 0.5-4.5V output
IP65 protection class
With cooling fan options, excellent performance for high temperature medium applications

Flush diaphragm; stainless steel body; high sensitivity; EMC and reverse polarity protection; for standard applications; high performance in high temperature applications up to 250°C with the option of cooling fan

 Pressure Range Output Operating Temperature Protection Linearity Datasheet
  -1…0~0.1bar…600bar 4-20mA, 0-10V, 0-5V, 0.5-4.5V -40~85°C (without cooling fan) 
-40~150°C (with 3 cooling fans)
-40°C~250°C (with 5 cooling fans) 
IP 65 ±0.5%FS