AWP 905 Draw Wire Sensor || ATEK || Made in Türkiye
2500mm, 4000mm or 5000mm stroke (measuring) lengths (Optional others)
±%0.5 FS linearity
Potentiometric, 0-10 VDC, 4-20 mA analog output or CANopen output
IP54 protection
Potentiometric measurement; robust stainless steel wire; suitable for long distance measurements; aluminum body suitable for outdoor use; resistant to shocks and vibrations
| Stroke (measuring) Lengths | Output Type | Protection | Linearity | Datasheet |
|---|---|---|---|---|
| 2500mm, 4000mm, 5000mm (optional other) | Potentiometric, 4-20 mA, 0-10 VDC or CANopen | IP 54 | ±%0,5 FS |
- 2500mm, 4000mm or 5000mm stroke (measuring) lengths (Optional others)
- Potentiometric, 0-10 VDC, 4-20 mA analog or CANopen output
- Aluminum anodized body
- Stainless steel measuring wire
- IP54 protection class
- Easy installation
- Shock/Vibration resistant
| Brand |
Atek |
|---|---|
| Stroke (measuring) Length |
2500mm, 4000mm, 5000mm (Optional others) |
| Linearity |
±%0.5 FS |
| Supply Voltage |
“A” and “V” models: 12…30 VDC |
| Output Signals |
Potentiometric |
| Measuring Type |
Potentiometric |
| Resistance |
5 KΩ (standard), 10 KΩ |
| Maximum Speed |
0.5 m/s |
| Required Force |
12 N |
| Operating Temp. |
-25°C … +85°C |
| Materials |
Housing: Aluminum/delrin |
| Connection Cable Length |
3m (standart), 5m, 10m |
| Protection Class |
IP54 |
- Elevators
- Press machines
- Crane systems
- Wood processing machines
- Marble processing machines
- Storage positioning
- Dam protections
- Sluice gate control
- Air compressors
- Glass processing machines
- Lifting platforms
- Applications in medical technologies (operating table etc.)
- Forklifts
- Screw machines
- Paper machines
- Sewing machines
- Hydraulic machines
- Sheet metal machines
- Printing machines
- Horizontal control equipments
- Construction machines
- Industrial robots
- Injection machines
- X-Y axis displacement
- Liquid level measurements and position control
Benzer Ürünler
Non-contact inductive measuring principle High linearity: 0.1% 0-20 mA or 4-20 mA analog output options Extra robust housing Long life IP67 or IP50 protection class
Inductive principle with absolute and very precise measurement; unlimited mechanical life due to non-contact; extra durability thanks to fully enclosed body; linear scale which is not affected by temperature changes thanks to special coil| Measuring Range | Output | Protection | Linearity | Datasheet |
|---|---|---|---|---|
| 10 mm | Analog (0-20 mA, 4-20 mA) | IP67 | ±0,1 %FS |
Non-contact magnetostrictive measurement Screw Flange Rod type body Absolute operating Operating pressure up to 350 bar Analog output options High precision up to 0.04% IP67 protection class
Non-contact and magnetostrictive measuring principle; internal connection to hydraulic or pneumatic cylinders; absolute operation, that is, not to lose position information in case of power failure| Measuring Range | Output | Protection | Linearity | Datasheet |
|---|---|---|---|---|
| 50 - 2000 mm | Analog (0.5-4.5 V, 0.25-4.75 V, 0-10 V, 4-20 mA) | IP 67 | ≤±%0,04 FS |
Precise potentiometric measurement Different measuring lengths from 10 mm to 100 mm Superior linearity up to 0.075% Motion life of up to 100 million Cable or socket version IP40 protection class
Precise and cost-effective position measurement; compact design; high speed operation; high repeatability value: 0.002 mm; push-back spring system
| Measuring Range | Output | Protection | Linearity | Datasheet |
|---|---|---|---|---|
| Different measuring lengths between 10 mm and 100 mm | Analog (potentiometric) | IP 40 | ±%0,075 |
Precise potentiometric measurement Different measuring lengths from 10 mm to 100 mm Superior linearity up to 0.04% High resolution: <0.01 mm Motion life of up to 50 million Cable or socket versions IP67 protection class
Precise position measurement with extra durable housing; easy mounting with ball joint at both sides; extra long life thanks to the special membrane that compensates the pressure on the shaft; extra protection against vibrations and corrosion
| Measuring Range | Output | Protection | Linearity | Datasheet |
|---|---|---|---|---|
| Different measuring lengths between 50 mm and 750 mm | Analog (potentiometric) | IP 67 | ±%0.04 |
Magnetic measurement Incremental encoder output Contactless / non-friction system Slim profile structure Measuring up to 20 meters Resolution options starting from 5µm IP67 protection class
High accuracy measurement with contactless magnetic system; Slim, retention profile closed system; Sealed protection against harsh environments with dust, humid and oil
| Measuring Range | Output | Protection | Magnetic Tape | Resolution | Datasheet |
|---|---|---|---|---|---|
| Up to 20 meters | Push-Pull, TTL RS422 Line Driver | IP 67 | B5 | 5µm, 10µm, 25µm, 50µm, 62.5µm, 100µm, optional other resolutions |
Incremental optical system Different mesuring lengths from 50 mm to 1000 mm Selectable reference signal at every 10 mm 5µm resolution IP54 protection class 60 m/min traversing speed Compatible with Delem, Cybelec and ESA
Accurate measurement with optical principle; Gasket protected aluminum housing; LED status indicators; Compact design, High accuracy and repeatability
| Measuring Range | Output Type | Protection | Resolution | Datasheet |
|---|---|---|---|---|
| Different measuring lengths from 50 mm to 1000 mm | TTL, Push Pull Line Driver, NPN | IP 54 | 5µm |
Linear Measurement
Rotary Measurement
Inclination/ Tilt Measurement
Laser Distance Sensors
Pressure Measurement
Level Measurement
Temperature Measurement
Liquid Flow Measurement
Proximity Sensors
Joysticks
Dro, Display and Counters
Elevator Light Curtains
Speed and Motion Measurement
Counting Sensors
Seismic / Earthquake Sensors
Mechanical Plunger Switches
Accelerometers
Faucet Sensors
Seam Detector Sensors
Encoder Signal Conditioner and Optical Isolator
Couplings
Cable and Connectors