AWP 820 Draw Wire Sensor || ATEK || Made in Türkiye
Different stroke (measuring) lengths between 6000 mm and 8000 mm
±0.5% FS linearity
2 m/s maximum speed
Potentiometric, 0-10 VDC, 4-20 mA analog output or CANopen output options
Redundant output model option
IP54 protection class
Potentiometric measurement; robust stainless steel wire; suitable for long distance measurements; anodised aluminum body; resistant to shocks and vibrations
Stroke (measuring) Lengths | Output | Protection | Linearity | Datasheet |
---|---|---|---|---|
Different measuring lengths between 6000 mm and 8000 mm | Potentiometric, 4-20 mA Current, 0-10 VDC Voltage or CANopen | IP 54 | ±0,5% FS | ![]() |
- Different stroke (measuring) lengths between 6000 mm and 8000 mm
- ±0.5% FS linearity
- Potentiometric, 0-10 VDC, 4-20 mA analog output or CANopen output options
- Redundant output model option
- IP54 protection class
- Compact design
- Easy installation
- 2 m/s maximum speed
- Shock/Vibration resistant
- Aluminum anodized body
Brand |
Atek |
---|---|
Stroke (measuring) length |
Different measuring lengths between 6000 mm and 8000 mm |
Linearity |
±%0.5 FS |
Supply Voltage |
‘A‘ and ‘V’ models: 12…30 VDC |
Signal Output Type |
Potentiometric |
Measuring Type |
Potentiometric |
Resistance |
5 KΩ (standart), 10 KΩ |
Maximum Speed |
2 m/s |
Required Force |
12 N |
Operating Temperature |
-25°C … +85°C |
Materials |
Housing: Aluminum/steel/plastic |
Connection cable length |
3m (standart), 5m, 10m |
IP Protection Class |
IP54 |
- Elevators
- Press machines
- Crane systems
- Wood processing machines
- Marble processing machines
- Storage positioning
- Dam protections
- Sluice gate control
- Air compressors
- Glass processing machines
- Lifting platforms
- Applications in medical technologies (operating table etc.)
- Forklifts
- Screw machines
- Paper machines
- Sewing machines
- Hydraulic machines
- Sheet metal machines
- Printing machines
- Horizontal control equipments
- Construction machines
- Industrial robots
- Injection machines
- X-Y axis displacement
- Liquid level measurements and position control
Benzer Ürünler
Non-contact inductive measuring principle High linearity: 0.1% 0-20 mA or 4-20 mA analog output options Extra robust housing Long life IP67 or IP50 protection class
Inductive principle with absolute and very precise measurement; unlimited mechanical life due to non-contact; extra durability thanks to fully enclosed body; linear scale which is not affected by temperature changes thanks to special coilMeasuring Range | Output | Protection | Linearity | Datasheet |
---|---|---|---|---|
10 mm | Analog (0-20 mA, 4-20 mA) | IP67 | ±0,1 %FS | ![]() |
Non-contact magnetostrictive measurement Screw Flange Rod type body Absolute operating Operating pressure up to 350 bar Analog output options High precision up to 0.04% IP67 protection class
Non-contact and magnetostrictive measuring principle; internal connection to hydraulic or pneumatic cylinders; absolute operation, that is, not to lose position information in case of power failureMeasuring Range | Output | Protection | Linearity | Datasheet |
---|---|---|---|---|
50 - 2000 mm | Analog (0.5-4.5 V, 0.25-4.75 V, 0-10 V, 4-20 mA) | IP 67 | ≤±%0,04 FS | ![]() |
Precise potentiometric measurement Different measuring lengths from 75 mm to 900 mm Linearity up to 0.04% <0.01 mm high resolution Motion life of up to 100 million IP55 protection class
Precise and long-lasting position measurement; measurement at very high speeds due to the narrow bearing tolerance of the spindle and the special material-coated surface
Measuring Range | Output | Protection | Linearity | Datasheet |
---|---|---|---|---|
Different measuring lengths between 75 mm and 900 mm | Analog (potentiometric) | IP 55 | ±%0,04 | ![]() |
Magnetic measurement Incremental utput Stroke up to 2000 mm Resolution options up to 1 µm IP65 protection class Compatible with Delem, Cybelec, ESA and STEP devices
High accuracy measurement with contactless magnetic system; special design for press brake machines; movable reference point; high tolerance to shock and vibrations; sealed protection against harsh environments with dust, humid and oilMeasuring Range | Output | Protection | Magnetic Tape | Resolution | Datasheet |
---|---|---|---|---|---|
Up to 2000 mm |
Push-Pull, TTL RS422 Line Driver |
IP 65 | B2 | 1µm, 5µm, 10µm, 25µm, 50µm, others on request | ![]() |
Incremental optical system Different mesuring lengths from 50 mm to 1000 mm Selectable reference signal at every 10 mm 5µm resolution IP54 protection class 60 m/min traversing speed Compatible with Delem, Cybelec and ESA
Accurate measurement with optical principle; Gasket protected aluminum housing; LED status indicators; Compact design, High accuracy and repeatability
Measuring Range | Output Type | Protection | Resolution | Datasheet |
---|---|---|---|---|
Different measuring lengths from 50 mm to 1000 mm | TTL, Push Pull Line Driver, NPN | IP 54 | 5µm | ![]() |
Stroke options from 100 mm to 3200 mm Incremental optical system Thick and long-distance body type Reference point at 50 mm intervals High resolution up to 1 μm IP54 protection class 60 m/min operating speed
Precise measurement on glass surface with optical principle; thick, long-distance body with single seal; 5 ball bearing system orientation; compact design, high accuracyMeasuring Range | Output Type | Protection | Resolution | Datasheet |
---|---|---|---|---|
Different measuring lengths from 100 mm to 3200 mm |
TTL RS-422
or Sinus |
IP 54 | 1µm, 5µm | ![]() |