TM1 Series (Screw Flange) || NOVOTECHNIK || Made in Germany
Non-contact magnetostrictive measurement
Screw Flange Rod type body
Absolute operating
Operating pressure up to 350 bar
Analog output options
High precision up to 0.04%
IP67 protection class
Non-contact and magnetostrictive measuring principle; internal connection to hydraulic or pneumatic cylinders; absolute operation, that is, not to lose position information in case of power failure
| Measuring Range | Output | Protection | Linearity | Datasheet |
|---|---|---|---|---|
| 50 – 2000 mm |
Analog (0.5-4.5 V, 0.25-4.75 V, 0-10 V, 4-20 mA)
|
IP 67
|
≤±%0,04 FS |
- Suitable for mobile and industrial applications
- Non-contact magnetostrictive principle
- Endless mechanical life due to completely non-contact measurement
- Special design which can be integrated into hydraulic and pneumatic cylinders thanks to rod type body
- Float reader magnet options suitable for liquid level measurement
- Ring reader magnet options for cylinders
- Speed ​​of movement of reader magnet is unlimited
- Absolute operating
- Operating up to 350 Bar, resistant to instant high pressures up to 450 bar
- Analog output options
- High sensitivity up to 0.04%
| Brand |
Novotechnic |
|---|---|
| Stroke Values |
Different models between 50 mm and 2000 mm |
| Resolution |
0,1 mm |
| Repeatability |
≤ ±0,1 mm |
| Linearity |
± %0.04 FS |
| Output Signals |
4 – 20 mA , 0 – 10 VDC, 0.5 – 4.5 VDC, 0.25 – 4,75 VDC |
| Overvoltage Protection |
36VDC (has reverse polarity protection) |
| Supply Voltage |
For 0.25 … 4.75 V and 0.5 … 4.5 V : 12/24 VDC (8 … 32 VDC) |
| Mounting |
Screwed into cylinder via bushing M18x1.5 for screw plug hole per ISO 6149 |
| Protection Class |
IP67 |
| Operating Temperature |
-40°C … +105°C |
| Life |
Mechanically unlimited |
| Electrical Connection |
With cable or socket |
- All hydraulic or pneumatic cylinders powered by fluid power
- Manufacturing industry
- Mobile Machines
- Liquid Level Measurement
Benzer Ürünler
Precise potentiometric measurement Different measuring lengths from 50 mm to 750 mm Linearity up to 0.04% <0.01 mm high resolution Motion life of up to 50 million IP65 protection class
Precise position measurement with robust housing; Easy to install with double beared actuating rod; Mountable via free from backlash pivot heads with a large angle of free movement
| Measuring Range | Output | Protection | Linearity | Datasheet |
|---|---|---|---|---|
| Different measuring lengths between 50 mm and 750 mm | Analog (potentiometric) | IP 65 | ±%0,04 |
Precise potentiometric measurement Different measuring lengths from 10 mm to 100 mm High resolution: <0.05 mm ± 1% linearity Motion life of up to 10 million Springless and back spring model options IP65 protection class
Precise and cost-effective position measurement; compact design; high speed operation; optional push back spring
| Measuring Range | Output | Protection | Linearity | Datasheet |
|---|---|---|---|---|
| Different measuring lengths between 10 mm and 100 mm | Analog (potentiometric) | IP 65 | ±%1 |
Magnetic measurement Measuring up to 4000 mm Resolution options starting from 5µm Self-embedded bearing system IP67 protection class Compatible with Delem, Cybelec and ESA
High accuracy measurement with contactless magnetic system; special design for press brake machines; self-aligning system; extra resistant to harsh conditions such as high temperature, speed or vibration
| Measuring Range | Output | Protection | Magnetic Tape | Resolution | Datasheet |
|---|---|---|---|---|---|
| Up to 4000 mm | Push-Pull, TTL RS422 Line Driver | IP 67 | B5 | 5µm, 10µm, 25µm, 50µm, 62.5µm, 100µm, optional other resolutions |
Magnetic measurement Incremental utput Stroke up to 2000 mm Resolution options up to 1 µm IP65 protection class Compatible with Delem, Cybelec, ESA and STEP devices
High accuracy measurement with contactless magnetic system; special design for press brake machines; movable reference point; high tolerance to shock and vibrations; sealed protection against harsh environments with dust, humid and oil| Measuring Range | Output | Protection | Magnetic Tape | Resolution | Datasheet |
|---|---|---|---|---|---|
| Up to 2000 mm |
Push-Pull, TTL RS422 Line Driver |
IP 65 | B2 | 1µm, 5µm, 10µm, 25µm, 50µm, others on request |
Incremental optical system Different mesuring lengths from 50 mm to 1000 mm Selectable reference signal at every 10 mm 5µm resolution IP54 protection class 60 m/min traversing speed Compatible with Delem, Cybelec and ESA
Accurate measurement with optical principle; Gasket protected aluminum housing; LED status indicators; Compact design, High accuracy and repeatability
| Measuring Range | Output Type | Protection | Resolution | Datasheet |
|---|---|---|---|---|
| Different measuring lengths from 50 mm to 1000 mm | TTL, Push Pull Line Driver, NPN | IP 54 | 5µm |
Stroke options from 100 mm to 1500 mm Incremental optical system Thick body type Reference point at 50 mm intervals High resolution up to 1 μm IP54 protection class 60 m/min operating speed
Optical precision measurement on glass surface; thick body with single gasket protection; 5 ball bearing system orientation; compact design, high accuracy| Measuring Range | Output Type | Protection | Resolution | Datasheet |
|---|---|---|---|---|
| Different measuring lengths from 100 mm to 1500 mm |
TTL RS-422
or Sinus |
IP 54 | 1µm, 5µm |
Linear Measurement
Rotary Measurement
Inclination/ Tilt Measurement
Laser Distance Sensors
Pressure Measurement
Level Measurement
Temperature Measurement
Liquid Flow Measurement
Proximity Sensors
Joysticks
Dro, Display and Counters
Elevator Light Curtains
Speed and Motion Measurement
Counting Sensors
Seismic / Earthquake Sensors
Mechanical Plunger Switches
Accelerometers
Faucet Sensors
Seam Detector Sensors
Encoder Signal Conditioner and Optical Isolator
Couplings
Cable and Connectors