MLC 310 Linear Scale || ATEK || Made in Türkiye
Magnetic measurement
Incremental encoder output
Contactless / non-friction system
Measuring up to 20 meters
Resolution options starting from 5µm
IP67 protection class
High accuracy measurement with contactless magnetic system; Retention profile closed system, Protection against harsh environments with dust, humid and oil
| Measuring Range | Output | Protection | Magnetic Tape | Resolution |
Datasheet |
|---|---|---|---|---|---|
| Up to 20 meters |
Push-Pull, TTL RS422 Line Driver
|
IP 67 | B5 | 5µm, 10µm, 25µm, 50µm, 62.5µm, 100µm, optional other resolutions |
- High accuracy and repeatability
- Magnetic measurement
- Resolution options starting at 5µm
- Contactless / non-friction system
- High tolerance to vibration and shocks
- Measuring up to 20 meters
- Resistant to dust, oil and moisture
- No maintenance required
- Robust aluminum body
- IP67 protection class
- Easy installation
*We highly recommend using our Process Control Devices to precisely display measured values on your Magnetic Linear Scale for motion conrolling, and our DRO(Digital Readout) Displays to use on metal working machines such as CNC, lathe etc.
| Brand |
Atek |
|---|---|
| Resolution |
5µm, 10µm, 25µm,50 µm, 62.5µm, 100µm (others on request) |
| Output Type |
Push-Pull or TTL RS422 Line Driver |
| Magnetic Tape |
B5 |
| Output Signals |
A, /A, B, /B, Z, /Z |
| Input Current |
Maximum 40 mA per channel |
| Supply Voltage |
PPL:10 … 30 VDC or TTL:5 VDC |
| Housing Material |
Sensor: Nickel Plated Aluminum |
| Electrical Connection |
D-Sub 9 pin, 5 or 8 x 0,14 mm2 shielded cable |
| Tape Reading Distance |
2 mm |
| Operating Speed |
3 m/s |
| Repeatability |
± 1 Pulse |
| Operating Temperature |
-25°C … +85°C |
| Protection Class |
IP67 |
- Woodworking
- Stone-cutting
- Sawing
- Metalworking
- Textiles
- Packaging
- Plastics processing
- Automation and assembly systems
- Laser/flame/water-jet cutting
- Electronic assembly lines
- Bohrwerk, CNC and lathe machines
- Machine press
Benzer Ürünler
Non-contact magnetostrictive measurement Plug-in Flange Rod type body Absolute operating Operating pressure up to 350 bar Analog output options High precision up to 0.04% IP67 or IP6K9K protection class
Non-contact and magnetostrictive measuring principle; internal connection to hydraulic or pneumatic cylinders; absolute operation, that is, not to lose position information in case of power failure
| Measuring Range | Output | Protection | Linearity | Datasheet |
|---|---|---|---|---|
| 50 - 2000 mm | Analog (0.5-4.5 V, 0.25-4.75 V, 0-10 V, 4-20 mA) | IP 67 / IP 69k | ≤±0,04 %FS |
Precise potentiometric measurement Different measuring lengths from 10 mm to 300 mm Linearity up to 0.05% <0.01 mm high resolution Motion life of up to 100 million Articulated, Rod and Spring model options IP54 protection class
Precise position measurement; Easy installation with compact and small design; 3 different body options: Articulated, Rod and Spring; cost effective solution| Measuring Range | Output | Protection | Linearity | Datasheet |
|---|---|---|---|---|
| Different measuring lengths between 10 mm and 300 mm | Analog (potentiometric) | IP 54 | ±%0,05 |
Precise potentiometric measurement Different measuring lengths from 10 mm to 100 mm Superior linearity up to 0.075% Motion life of up to 100 million Cable or socket version IP40 protection class
Precise and cost-effective position measurement; compact design; high speed operation; high repeatability value: 0.002 mm; push-back spring system
| Measuring Range | Output | Protection | Linearity | Datasheet |
|---|---|---|---|---|
| Different measuring lengths between 10 mm and 100 mm | Analog (potentiometric) | IP 40 | ±%0,075 |
Precise potentiometric measurement Different measuring lengths from 10 mm to 100 mm High resolution: <0.05 mm ± 1% linearity Motion life of up to 10 million Springless and back spring model options IP65 protection class
Precise and cost-effective position measurement; compact design; high speed operation; optional push back spring
| Measuring Range | Output | Protection | Linearity | Datasheet |
|---|---|---|---|---|
| Different measuring lengths between 10 mm and 100 mm | Analog (potentiometric) | IP 65 | ±%1 |
Magnetic measurement Incremental utput Stroke up to 2000 mm Resolution options up to 1 µm IP65 protection class Compatible with Delem, Cybelec, ESA and STEP devices
High accuracy measurement with contactless magnetic system; special design for press brake machines; movable reference point; high tolerance to shock and vibrations; sealed protection against harsh environments with dust, humid and oil| Measuring Range | Output | Protection | Magnetic Tape | Resolution | Datasheet |
|---|---|---|---|---|---|
| Up to 2000 mm |
Push-Pull, TTL RS422 Line Driver |
IP 65 | B2 | 1µm, 5µm, 10µm, 25µm, 50µm, others on request |
Contactless and frictionless operation Precise measurement up to 1000 mm Resolution options starting from 5 µm Push-Pull, TTL RS422 Line Driver output Articulated on both sides IP 65 Protection class
Magnetic principle-operated double side articulation linear encoder; infinite mechanical lifetime from contactless operation; high operating speed of up to 3 m/s
| Maximum Measuring Length | Output | Protection | Resolution | Datasheet |
|---|---|---|---|---|
| Up to 1000 mm | Push-Pull, TTL RS422 Line Driver | IP 65 | 5 µm, 10 µm, 20 µm, 25 µm, 62.5 µm, 80µm, 100 µm |