AWI 100 Programmable Draw Wire Sensor With Integrated Inclinometer || ATEK ALFA || Made in Türkiye

  • Integrated inclination sensor option for simultaneous length and inclination measurement
  • Different stroke (measuring) lengths up to 10000 mm (10 meters)
  • Selectable angle values between 0…360° or ±180° for inclination measurement
  • Analog or CANopen output
  • Programmable analog output option
Technical Datasheet
PDF
Description
  • Integrated inclination sensor option for simultaneous length and inclination measurement
  • Different stroke (measuring) lengths up to 10000 mm (10 meters)
  • Analog or CANopen output
  • Programmable analog output option for length measurement
  • Selectable angle values between 0…360° or ±180° for inclination measurement
  • Ability to determine the 0⁰ point for inclination measurement
  • IP67 protection class
  • Compact design and easy installation
  • 1 m/s maximum movement speed
  • Shock / vibration resistant structure
Applications
  • Fixed or mobile cranes
  • Fire and rescue vehicles
  • Transport systems
  • Excavators
  • Lifting and working platforms
  • Machines
Additional Information
AccuracyDraw Wire Sensor: ±%0.5 FS, Inclinometer: 0,2°
Baud Rate10 kBit/s, 20 kBit/s, 50 kBit/s, 100 kBit/s, 125 kBit/s, 250 kBit/s, 500 kBit/s, 800 kBit/s, 1 Mbit/s
Electrical ConnectionM12 connector or cable
Error ControlHeartbeat, Emergency Message
ID (Node ID) It can be set from 1 to 127 with LSS or SDO. Default Node ID:1
Inclination Sensor Measurement RangeDifferent angle values between 0…360°, Different angle values between ±180°
Material Body: Aluminum, Measuring Wire: Stainless Steel
Maximum Speed1 m/s
Measuring Distance AWI 105: Different lengths up to 5000 mm , AWI 110: Different lengths up to 10000 mm
Operating Temperature-40 … +85 °C
PDO3 Tx PDO
PDO Data Rate100 ms
PDO ModesEvent/Time triggered, Synch/Asynch
Protection ClassIP67
Resolution Draw Wire Sensor: 0.05 mm, Inclinometer: 12 bit
Response Frequency Draw Wire Sensor: 500 Hz, Inclinometer: 10Hz
Reverse Connection ProtectionYes
SDO1 server
Serial Communication (Optional)CiA 301
Short Circuit ProtectionYes
String Sensor Measurement Range AWI 105: Different lengths up to 5000 mm , AWI 110: Different lengths up to 10000 mm
Supply Voltage Analog: 15 … 26 VDC , CANopen: 12 … 30 VDC
Termination ResistanceOptional
Downloads
Technical Datasheet
PDF
CAD/STEP File
ZIP Archive
CAN-EDS File
RAR Archive