DN Series Electromagnetic Flowmeter (Integrated Type) || ATEK ||
Electromagnetic working principle
15-1200 mm variable diameter measurement
±0.2% or ± 0.5% accuracy
Analogue or digital output options
220VAC or 24VDC supply
IP65 protection class
Robust housing
Electromagnetic flowmeter capable of measuring up to 7000 m³ / h and 4-20mA and other outputs
| Measurement Range | Output | Accuracy | Protection | Datasheet |
|---|---|---|---|---|
| Up to 7000 m³/h | 4-20 mA (standard), Pulse, RS485, HART, Profibus-PA | ±%0,2 or ±%0,5 | IP 65 |
- Working principle based on electromagnetic induction law
- Ability to measure with variable diameter of 15-1200mm
- Long-term perfect work
- Stainless body construction
- Suitable for harsh ambient conditions
| Brand |
Atek |
|---|---|
| Basic Error |
±0.2% or ±0.5% of indicated value |
| Diameter (mm) |
DN15-DN2400 (IP67) |
| Body |
Comply with GB9119 standard, Carbon steel (Stainless steel optional) |
| Pressure Level |
DN15-DN600 10, 16, 25, 40 BAR |
| Lining Material |
PTFE, PU, CR, PFA, F46, IR |
| Conductivity |
≥5uS/cm |
| Electrode |
316L, Hastelloy, Titanium, Tantalum, Platinum iridium coated |
| Output Signal |
Standard (4-20mA), Pulse, RS485, HART, Profibus-PA |
| Analog Output Error |
≤±0.02mA |
| Supply Voltage |
220 VAC or 24 VDC |
| Repetition |
≤±0.1%, ±0.25% |
| Protection Class |
IP65 |
| Operating Temp. |
-25°C…+80°C |
| Ambient Temp. |
-25°C… +60°C <±0.1%/10℃ or <±0.25%/10℃ |
| Measuring range velocity |
≤20m/s |
| Electrical Connection |
M20×1.5 seal, G1/2, NPT1/2 |
- Chemistry
- Petro Chemistry
- Water technologies
- Automation application
Benzer Ürünler
Electromangnetic working principle ±0,2% accuracy Analog or digital output options 220VAC or 24VDC power supply IP65 protection class Robust housing
Excellent flow mesurement accuracy, can measure duplex flow, electromagnetic debimeter with 4-20mA and other outputs
| Measurement Value | Output | Accuracy | Protection | Datasheet |
|---|---|---|---|---|
| 3 m/s | 4-20 mA (pulse, RS-232, RS-485, HART) | ±0,2% | IP 65 |
Electromagnetic working principle 15-1200 mm variable diameter measurement ±0.2% or ± 0.5% accuracy Analogue or digital output options 220VAC or 24VDC supply IP65 or IP68 protection class Robust housing
Electromagnetic flowmeter capable of measuring up to 7000 m³ / h and 4-20mA and other outputs
| Measurement Range | Output | Accuracy | Protection | Datasheet |
|---|---|---|---|---|
| Up to 7000 m³/h | 4-20 mA (standard), Pulse, RS485, HART, Profibus-PA | ±%0,2 or ±%0,5 | IP 65, IP 68 |
Ultrasonic working principle ±0,5% accuracy Analog or digital output options 220VAC or 24VDC power supply IP65 protection class Robust housing
Ultrasonic flow meter with perfect measurement precision and flexible display
| Max Flow Velocity | Output | Accuracy | Protection | Datasheet |
|---|---|---|---|---|
| 64 m/s | 4-20 mA, MODBUS, M-BUS, FUJI | ±%0,5 | IP 65 |
Ultrasonic working principle ±1% accuracy RS-232 output Rechargeable battery IP65 protection class Robust housing
Handheld ultrasonic flow meter with RS-232 output, with high accuracy, stability, easy operation and carrying
| Max Flow Velocity | Output | Accuracy | Protection | Datasheet |
|---|---|---|---|---|
| 64 m/s | RS-232 | ±%1 | IP 65 |