{"id":17271,"date":"2023-08-25T14:14:54","date_gmt":"2023-08-25T14:14:54","guid":{"rendered":"https:\/\/alfasanayi.com\/efm-series-electromagnetic-flowmeter-atek\/"},"modified":"2023-08-25T14:14:54","modified_gmt":"2023-08-25T14:14:54","slug":"efm-series-electromagnetic-flowmeter-atek","status":"publish","type":"product","link":"https:\/\/alfasanayi.com\/en\/product\/efm-series-electromagnetic-flowmeter-atek\/","title":{"rendered":"EFM Series Electromagnetic Flowmeter || ATEK ||"},"content":{"rendered":"<ul>\n<li>Accuracy: \u00b12%of the mesurement value +0.3m\/s<\/li>\n<li>Excellent small flow mesurement accuracy, can measure duplex flow<\/li>\n<li>IP68 protection class<\/li>\n<li>Pipe connection: JIS 10K, JIS20K, ANSI150, ANSI300, DIN PN10, DIN PN16<\/li>\n<li>Cold, heat measure function<\/li>\n<li>Double frequency excitation, stable zero point<\/li>\n<li>Self-diagnosis, intelligent work<\/li>\n<li>Build-in ground electrode, no need the grounding ring<\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p class=\"for-shop-desc\">Electromangnetic working principle<br \/>\n\u00b10,2% accuracy<br \/>\nAnalog or digital output options<br \/>\n220VAC or 24VDC power supply<br \/>\nIP65 protection class<br \/>\nRobust housing\n<\/p>\n<p>Excellent flow mesurement accuracy, can measure duplex flow, electromagnetic debimeter with 4-20mA and other outputs\n<\/p>\n<div class=\"datasheet-pdf\" ><a href=\"\/wp-content\/uploads\/2023\/08\/EFM_elektromanyetik_debimetre_tr.pdf\" target=\"_blank\" rel=\"noopener\"><img decoding=\"async\" src=\"\/wp-content\/uploads\/2023\/07\/pdf-1.png\" width=\"50\" height=\"50\" \/><br \/>\nDatasheet<\/a><\/div>\n<div class=\"datasheet-pdf tr-en-section\" style=\"display: flex;\">\n<div class=\"tr-button\"><a id=\"button\" href=\"\/wp-content\/uploads\/2023\/08\/EFM_elektromanyetik_debimetre_tr.pdf\" target=\"_blank\" rel=\"noopener\">TR<\/a><\/div>\n<div class=\"tr-button\"><a id=\"button\" href=\"\/wp-content\/uploads\/2023\/08\/EFM_electromagnetic_flowmeter_en.pdf\" target=\"_blank\" rel=\"noopener\">EN<\/a><\/div>\n<\/div>\n<table class=\"datasheet-table\" style=\"width: 100%; margin-left: auto; margin-right: auto;\" border=\"1\" cellspacing=\"5\" cellpadding=\"5\">\n<tbody>\n<tr style=\"height: 16px;\">\n<th style=\"text-align: center; vertical-align: middle; height: 16px; width: 14.2809%;\"><span style=\"font-size: 13.3333px;\">Measurement Value<\/span><\/th>\n<th style=\"text-align: center; vertical-align: middle; height: 16px; width: 21.7191%;\"><span style=\"font-size: 10pt;\"><strong>Output<\/strong><\/span><\/th>\n<th style=\"text-align: center; vertical-align: middle; height: 16px; width: 14%;\"><span style=\"font-size: 10pt;\"><strong>Accuracy<\/strong><\/span><\/th>\n<th style=\"text-align: center; vertical-align: middle; height: 16px; width: 10%;\"><span style=\"font-size: 10pt;\">Protection<\/span><\/th>\n<th style=\"text-align: center; vertical-align: middle; height: 16px; width: 10%;\"><span style=\"font-size: 10pt;\"> Datasheet<\/span><\/th>\n<\/tr>\n<tr style=\"height: 33.3125px;\">\n<td style=\"text-align: center; vertical-align: middle; height: 33.3125px; width: 14.2809%;\"><span style=\"font-size: 10pt;\">3 m\/s<\/span><\/td>\n<td style=\"text-align: center; vertical-align: middle; height: 33.3125px; width: 21.7191%;\">&nbsp;<span style=\"font-size: 10pt;\">4-20 mA (pulse, RS-232, RS-485, HART)<\/span><\/td>\n<td style=\"text-align: center; vertical-align: middle; height: 33.3125px; width: 14%;\"><span style=\"font-size: 10pt;\">\u00b10,2%<\/span><\/td>\n<td style=\"text-align: center; vertical-align: middle; height: 33.3125px; width: 10%;\"><span style=\"font-size: 10pt;\">IP 65<\/span><\/td>\n<td style=\"text-align: center; vertical-align: middle; height: 33.3125px; width: 10%;\"><a href=\"\/wp-content\/uploads\/2023\/08\/EFM_electromagnetic_flowmeter_en.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><img decoding=\"async\" src=\"\/wp-content\/uploads\/2023\/08\/shop-page-pdf.png\" alt=\"\" width=\"36\" height=\"36\" align=\"center\"><\/a><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":15865,"template":"","meta":[],"product_cat":[222,221],"product_tag":[],"class_list":["post-17271","product","type-product","status-publish","has-post-thumbnail","product_cat-electromagnetic-flowmeters","product_cat-liquid-flow-measurement","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/alfasanayi.com\/en\/wp-json\/wp\/v2\/product\/17271","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/alfasanayi.com\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/alfasanayi.com\/en\/wp-json\/wp\/v2\/types\/product"}],"version-history":[{"count":0,"href":"https:\/\/alfasanayi.com\/en\/wp-json\/wp\/v2\/product\/17271\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/alfasanayi.com\/en\/wp-json\/wp\/v2\/media\/15865"}],"wp:attachment":[{"href":"https:\/\/alfasanayi.com\/en\/wp-json\/wp\/v2\/media?parent=17271"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/alfasanayi.com\/en\/wp-json\/wp\/v2\/product_cat?post=17271"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/alfasanayi.com\/en\/wp-json\/wp\/v2\/product_tag?post=17271"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}