BCT 24S Combined Pressure and Temperature Transmitter || ATEK ALFA || Made in Türkiye

  • Pressure and temperature measurement with a single sensor
  • Pressure ranges from 60 bar to 600 bar
  • Temperature measurement from -40 … +125°C
  • 4-20 mA, 0-10 V, 0.5-4.5 V Ratiometric, PT100, PT1000 output options
  • G1/4, G1/2, NPT1/4, NPT1/2, M14x1 mechanical connection options
Technical Datasheet
PDF
Description
  • Simultaneous pressure and temperature measurement with a single sensor
  • Piezoresistive operating principle
  • 26 mm stainless steel housing
  • Pressure measuring range options from 60Bar to 600Bar
  • -40 … +125°C temperature measurement
  • 4-20mA, 0-10V, 0.5-4.5V Ratiometric, PT100, PT1000 output options
  • G1/4, G1/2, NPT1/4, NPT1/2, M14x1 process connection options
  • EMC and reverse polarity protection
  • High accuracy and stability
Applications
  • Process automation and control systems
  • Cooling, air conditioning, and HVAC systems
  • Hydraulic equipment and valve control systems
  • Biomedical devices and equipment
  • Marine, ship systems, and navigation applications
  • Aviation and avionics systems
Additional Information
Accuracy Pressure: ±0.5%FS (@0°C~70°C) , Temperature: ±0.5% FS (@0°C~70°C)
BrandATEK ALFA
Current Consumption 2 telli : ≤20 mA @24VDC , 3 telli : <30 mA @24VDC
Electrical ConnectionM12 connector or cable
Material Body: 303 stainless steel , Diaphragm: 316L stainless steel
Measurement Type Pressure: Piezoresistive sensor , Temperature: PT100, PT1000 (Class A EN60751)
Measuring Range Pressure: 60Bar, 100Bar, 160Bar, 250Bar, 400Bar, 600Bar , Temperature: -40 … +125°C
Mechanical ConnectionG1/4, G1/2, NPT1/4, NPT1/2, M14x1
Operating Temperature -40°C … +125°C
Output Signals 2 telli 4-20mA std., 0-10V, 0.5-4.5V Ratiometric , PT100, PT1000
Overload ProtectionYes
Protection Class IP65 or IP67 *IP67 protection is provided if M12 connector models are equipped with press-printed connectors.
Reaction Time Pressure: 25ms (standard) … nominal pressure 1ms, 5ms, 125ms (optional) , Temperature: 1sn
Reverse Connection ProtectionYes
Short Circuit ProtectionYes