Contactless Linear Position Sensors
Non-contact and magnetostrictive measuring principle; internal connection to hydraulic or pneumatic cylinders; absolute operation, that is, not to lose position information in case of power failure
Measuring Range | Output | Protection | Linearity | Datasheet |
---|---|---|---|---|
50 - 2000 mm |
Analog (0.5-4.5 V, 0.25-4.75
V,
0-10 V, 4-20 mA)
|
IP 67 / IP 69k
|
≤±0,04 %FS |
![]() |
Non-contact and magnetostrictive measurement in robust profile; endless mechanical life because it works without mechanical friction; absolute operation, that is, not to lose position information in case of power failure
Measuring Range | Output | Protection | Linearity | Datasheet |
---|---|---|---|---|
50 - 4250 mm | Analog (Curent or Voltage), Start-Stop, SSI, Incremental, CANopen | IP 68 | ≤±0.02 %FS |
![]() |
Non-contact and inductive measuring principle; ability to measure at high speeds; 10 kHz refresh rate; infinite mechanical life; resistant to magnetic field; Very high sensitivity and resolution
Measuring Range | Output | Protection | Linearity | Datasheet |
---|---|---|---|---|
100 - 1000 mm | Analog(Curent or Voltage), SSI, IO-Link, CANopen | IP 67 | ≤±0.025 %FS |
![]() |
Non-contact and magnetostrictive measurement; special design for integrated hydraulic cylinders; infinite mechanical life; float reader magnet option suitable for liquid level measurement; absolute operation, that is, not to lose position information in case of power failure
Measuring Range | Output | Protection | Linearity | Datasheet |
---|---|---|---|---|
50 - 4250 mm | Analog (Curent or Voltage), SSI, IO-Link, CANopen, Start-Stop-Impulse | IP 67 / IP68 | ≤±0.02 %FS |
![]() |
Non-contact and magnetostrictive measuring principle; internal connection to hydraulic or pneumatic cylinders; absolute operation, that is, not to lose position information in case of power failure
Measuring Range | Output | Protection | Linearity | Datasheet |
---|---|---|---|---|
50 - 2000 mm |
Analog (0.5-4.5 V, 0.25-4.75
V,
0-10 V, 4-20 mA)
|
IP 67
|
≤±%0,04 FS |
![]() |
Compact body and tie rod design on both sides; absolute precision measurement with inductive principle; endless mechanical life because it is non-contact; Adjustable measuring parameters with teach-in function
Measuring Range | Output | Protection | Linearity | Datasheet |
---|---|---|---|---|
25 - 200 mm |
Analog (0.1-10V, 10-01.V, 4-20mA,
20-4mA)
|
IP 40
|
< ±0,1 %FS |
![]() |
Inductive principle with absolute and very precise measurement; unlimited mechanical life due to non-contact; extra durability thanks to fully enclosed body; linear scale which is not affected by temperature changes thanks to special coil
Measuring Range | Output | Protection | Linearity | Datasheet |
---|---|---|---|---|
10 mm |
Analog (0-20 mA, 4-20 mA)
|
IP67
|
±0,1 %FS |
![]() |