EXNA 8854 Ex-Proof Pressure Transmitter || TRAFAG || Swiss Made
Suitable for use in explosive environments
Atex and IECEx certified
Versions with frontal or with flush diaphragm
Options from 0 … 0.1 bar to 0 … 1000 bar
±0.1% FS or ±0.25% FS accuracy
4-20 mA analog output
IP68 protection class
Piezoresistive submersible pressure transmitter; Ex-Proof certified, explosion-proof; Versions with frontal or with flush diaphragm; DIN43650 connector, M12 connector, PUR or FEP cable options
| Measuring Range | Output | Protection | Accuracy | Datasheet |
|---|---|---|---|---|
| 0 … 0.1 to 0 … 1000 bar | 4-20 mA |
IP68
|
±%0.1 FS, ±%0.25 FS |
- Piezoresistive meauring principle
- Ex-Proof certified by IECEx and ATEX
- DIN43650 connector, M12 connector, PUR or FEP cable options
- Versions with frontal or with flush diaphragm
- Available in various options from 0 … 0,1 bar to 0 … 1000 bar
- High accuracy up to ±0.1% FS
- EMC protected
- IP 68 protection class
- 4-20 mA analog output
- PUR cables are abrasion resistant, suitable for food and light chemical industry.
- FEP cables are very similar to Teflon, they are more durable. Similar to PUR cables, suitable for use in higher and lower temperatures for the heavy chemical industry.
| Brand |
Trafag |
|---|---|
| TECHNICAL FEATURES |
–> |
| Measuring principle |
Piezoresistive |
| Measuring range |
0 … 0.1 to 0 … 1000 bar |
| Output signal |
4 … 20 mA |
| Accuracy |
± 0.1 %FS |
| Ambient temperature |
T3: -40°C … +150°C |
| IP protection class |
IP68 |
| Pressure Connection |
1/4” NPT M |
| Approval / conformity |
DNV-GL |
- Ex Zone 0, 1, 2 / Gas
- Ex Zone 20, 21, 22 / Dust
- Ex Underground Mining
Benzer Ürünler
Marine certified With ceramic diaphragm Stainless steel or titanium body Options from 0 ... 0.1 bar to 0 ... 250 bar ±0.3% FS sensitivity 4-20 mA analog output IP65, IP67 or IP68 protection class Economical and convenient solution
Pressure transmitter with ceramic diaphragm; marine certified; economic and durable; relative or absolute measurement option
| Measuring Range | Output | Protection | Accuracy | Datasheet |
|---|---|---|---|---|
| 0 ... 0.1 to 0 ... 250 bar | 4-20 mA | IP65, IP67, IP68 | ±%0.3 FS |
Piezoresistive working principle Stainless steel housing 10Bar and 16Bar models 4-20mA analog output ±0.5% F.S accuracy IP65 protection class Compact construction
Stainless steel body; high sensitivity; EMC and reverse polarization protected; small and compact design| Measuring Range | Output | Protection | Accuracy | Body Diameter | Datasheet |
|---|---|---|---|---|---|
| 0…10bar and 0…16bar | 4-20 mA | IP65 | ±%0,5 F.S | 24mm |
Thin film steel diaphragm, flush membrane Stainless steel body Options from -0.5 ... 0.5 bar to 0 ... 100 bar ±0.5% FS sensitivity Different analog output options IP65, IP67 or IP68 protection class
Pressure transmitter with steel diaphragm and flush membrane; one-piece welded sealing body for high durability and resistance to ambient conditions; very small compact design; special smooth and flat flush membrane
| Measuring Range | Output | Protection | Accuracy | Datasheet |
|---|---|---|---|---|
| -0.5 ... 0.5 to 0 ... 100 bar | 4-20 mA, 0-10 VDC, 0-5 VDC, 1-6 VDC, 0.5-4.5 VDC ratiometric | IP65, IP67, IP68 | ±%0.5 FS |
Thin film steel diaphragm Stainless steel body Options from 0 ... 2,5 bar to 0 ... 600 bar ±0.3% FS, ± 0.15% FS, ± 0.1% FS accuracy Different analog output options IP 65 or IP67 protection class
Pressure transmitter with steel diaphragm ; high sensitivity values; one-piece welded sealing body for high durability and resistance to ambient conditions; smallest compact design; extra high pressure resistance
| Measuring Range | Output | Protection | Accuracy | Datasheet |
|---|---|---|---|---|
| 0 ... 2.5 to 0 ... 600 bar | 4-20 mA, 0-5 VDC, 0-10 VDC, 1-6 VDC, 0.5-4.5 VDC ratiometric | IP65, IP67 | ±%0.3 FS, ±%0.15 FS, ±%0.1 FS |
100mbar…100bar pressure range Suitable for sanitary applications Suitable for 1.5" tri-clamp connection ±0.5%FS accuracy 4-20 mA, 0-10V etc. analog output options IP65 protection
BT10-211 flush pressure transmitter is applicable to food, beverage, pharmaceutical and biological engineering. Full metal flush-mounting isolation diaphragm is directly welded with process connection to ensure the precision connection between process connection and measuring diaphragm. Therefore, no additional sealing gaskets are required, and it ensures there are no measurement dead zones.| Pressure Range | Output | Protection | Accuracy | Datasheet |
|---|---|---|---|---|
| 0...100 mBar to 0...100 Bar | 4-20mA, 0-20mA, 0-10V, 1-6V, 0-5V, Ratiometric | IP 65 | ±0.5%FS |
Pressure Switch with indicator Options from 0 ... 0.2 bar to 0 ... 100 bar ±0.5% FS sensitivity Analog output options 2 PNP transistor outputs IP67 protection class
Pressure transmitter and switch with indicator in one device; thick film ceramic diaphragm; programming from mobile phone with NFC; current and voltage output option in one device; absolute or relative measurement; 2 PNP transistor outputs
| Measuring Range | Output | Protection | Accuracy | Datasheet |
|---|---|---|---|---|
| 0 ... 0.2 to 0 ... 100 bar | 4-20 mA, 0-10 VDC, 0-5 VDC, 1-6 VDC, switchable mA or V, PNP transistor | IP67 | ±0.5% FS |
Linear Measurement
Rotary Measurement
Inclination/ Tilt Measurement
Laser Distance Sensors
Pressure Measurement
Level Measurement
Temperature Measurement
Liquid Flow Measurement
Proximity Sensors
Joysticks
Dro, Display and Counters
Elevator Light Curtains
Speed and Motion Measurement
Counting Sensors
Seismic / Earthquake Sensors
Mechanical Plunger Switches
Accelerometers
Faucet Sensors
Seam Detector Sensors
Encoder Signal Conditioner and Optical Isolator
Couplings
Cable and Connectors