AWP 210 Draw Wire Sensor || ATEK || Made in Türkiye
Different stroke (measuring) lengths between 1000 mm and 5000 mm
±0.5% FS linearity
2 m/s maximum speed
Potentiometric, 0-10 VDC or 4-20 mA analog output
Easy mounting
IP53 protection class
Potentiometric measurement; robust stainless steel wire; anodised aluminum body; resistant to shocks and vibrations
Stroke (measuring) Lengths | Output | Protection | Linearity | Datasheet |
---|---|---|---|---|
Different measuring lengths between 1000 mm and 5000 mm | Potentiometric, 4-20 mA Current, 0-10 VDC Voltage | IP 53 | ±0,5% FS | ![]() |
- Different stroke (measuring) lengths between 1000 mm and 5000 mm
- ±0.5% FS linearity
- Potentiometric, 0-10 VDC or 4-20 mA analog output options
- IP53 protection class
- Compact design
- Easy installation
- 2 m/s maximum speed
- Shock/Vibration resistant
- Aluminum anodized body
Brand |
Atek |
---|---|
Stroke (measuring) length |
Different measuring lengths between 1000 mm and 5000 mm |
Linearity |
±%0.5 FS |
Supply Voltage |
‘A‘ and ‘V’ models: 12…30 VDC |
Signal Output Type |
Potentiometric |
Measuring Type |
Potentiometric |
Resistance |
5 KΩ (standard), 10 KΩ |
Maximum Speed |
2 m/s |
Required Force |
10 N |
Operating Temperature |
-25°C … +85°C |
Materials |
Housing: Aluminum/steel /plastic |
Connection cable length |
3m (standard), 5m, 10m |
IP Protection Class |
IP53 |
- Elevators
- Press machines
- Crane systems
- Wood processing machines
- Marble processing machines
- Storage positioning
- Dam protections
- Sluice gate control
- Air compressors
- Glass processing machines
- Lifting platforms
- Applications in medical technologies (operating table etc.)
- Forklifts
- Screw machines
- Paper machines
- Sewing machines
- Hydraulic machines
- Sheet metal machines
- Printing machines
- Horizontal control equipments
- Construction machines
- Industrial robots
- Injection machines
- X-Y axis displacement
- Liquid level measurements and position control
Benzer Ürünler
Non-contact magnetostrictive measurement Plug-in Flange Rod type body Absolute operating Operating pressure up to 350 bar Analog output options High precision up to 0.04% IP67 or IP6K9K protection class
Non-contact and magnetostrictive measuring principle; internal connection to hydraulic or pneumatic cylinders; absolute operation, that is, not to lose position information in case of power failure
Measuring Range | Output | Protection | Linearity | Datasheet |
---|---|---|---|---|
50 - 2000 mm | Analog (0.5-4.5 V, 0.25-4.75 V, 0-10 V, 4-20 mA) | IP 67 / IP 69k | ≤±0,04 %FS | ![]() |
Precise potentiometric measurement Different measuring lengths from 25 mm to 150 mm Superior linearity up to 0.075% Motion life of up to 100 million Cable or socket version IP40 protection class
Precise and cost-effective position measurement; compact design; high speed operation; High repeatability value: 0.002 mm
Measuring Range | Output | Protection | Linearity | Datasheet |
---|---|---|---|---|
Different measuring lengths between 25mm and 150 mm | Analog (potentiometric) | IP 40 | ±%0,075 | ![]() |
Precise potentiometric measurement Different measuring lengths from 10 mm to 100 mm Superior linearity up to 0.075% Motion life of up to 100 million Cable or socket version IP40 protection class
Precise and cost-effective position measurement; compact design; high speed operation; high repeatability value: 0.002 mm; push-back spring system
Measuring Range | Output | Protection | Linearity | Datasheet |
---|---|---|---|---|
Different measuring lengths between 10 mm and 100 mm | Analog (potentiometric) | IP 40 | ±%0,075 | ![]() |
Magnetic measurement Incremental utput Stroke up to 2000 mm Resolution options up to 5 µm IP65 protection class Compatible with Delem, Cybelec, ESA and STEP devices
High accuracy measurement with contactless magnetic system; special design for press brake machines; movable reference point; high tolerance to shock and vibrations; sealed protection against harsh environments with dust, humid and oil
Measuring Range | Output | Protection | Magnetic Tape | Resolution | Datasheet |
---|---|---|---|---|---|
Up to 2000 mm | Push-Pull, TTL RS422 Line Driver | IP 65 | B2 | 5µm, 10µm, 25µm, 50µm, others on request | ![]() |
Stroke options from 50 mm to 1000 mm Incremental optical system Slim body type Reference point at 50 mm intervals High resolution options up to 1 μm IP54 protection class 60 m/min operating speed
Optical precision measurement on glass surface; thin body with single or double gasket protection; 5 ball bearing system orientation; compact design, high accuracy
Measuring Range | Output Type | Protection | Resolution | Datasheet |
---|---|---|---|---|
Different measuring lengths from 50 mm to 1000 mm | 5 VDC TTL Quadrature or 1 Vpp Sinus | IP 54 | 1µm, 5µm | ![]() |
Stroke options from 50 mm to 1500 mm Incremental optical system Thick body type Reference point at 50 mm intervals High resolution up to 1 μm IP54 protection class 60 m/min operating speed
Optical precision measurement on glass surface; thick body with single gasket protection; 5 ball bearing system orientation; compact design, high accuracy
Measuring Range | Output Type | Protection | Resolution | Datasheet |
---|---|---|---|---|
Different measuring lengths from 50 mm to 1500 mm | 5 VDC TTL Quadrature or 1Vpp Sinus | IP 54 | 1µm, 5µm | ![]() |