AWP 110 HR High Resolution Programmable Draw Wire Sensor (IP67) || ATEK || Made in Türkiye
0…1200 mm stroke (measuring) length
High resolution
±%0.25 FS linearity
2 m/s maxium speed
Analog or CANopen output
Programmable analog output
Small structure
IP67 protection class
Magnetic measurement; high resolution; robust stainless steel wire; small aluminum body; resistant to shocks and vibrations
Stroke (measuring) Lengths | Resolution | Output Type | Protection | Linearity | Datasheet |
---|---|---|---|---|---|
0…1200 mm | CANopen: 6µm Analog: 16 bit |
Analog:4-20 mA, 0-10 V, 0-5 V, 0.5-4.5 V CANopen |
IP67 | ±%0,25 FS | ![]() |
- 0…1200 mm stroke (measuring) length
- High resolution
- ±%0.25 FS linearity
- Analog or CANopen interface
- Thanks to the teachi-in feature, the minimum and maximum measurement limits can be adjusted on the sensor
- IP67 protection class
- 2 m/s maximum speed
- Shock/vibration resistant
- Robust aluminum housing and stainless steel measuring wire
- Compact design
Brand |
Atek |
---|---|
Working Principle |
Hall Effect |
Electrical Interface |
Analog:4-20 mA, 0-10 V, 0-5 V, 0.5-4.5 V |
Supply Voltage |
Analog: 15…26VDC |
Current Consumption |
60 mA |
Reverse polarity protection |
Yes |
Resolution |
Analog: 16bit |
Electrical Connection |
M12 / 5 pin male connector |
Required Force |
5 N |
Max Speed |
2 m/s |
Linearity |
±%0.25 FS |
Ağırlık |
≈ 460 gr |
Protection Class |
IP67 |
Operating Temp. |
-20 … +85 °C |
Relative Humudity |
… |
Material |
Body: Aluminum |
Communication Profile |
CiA 301 |
Device Type |
CANopen, CiA DS406 |
Node ID |
It can be set from 1 to 127 with LSS or SDO. |
Baud Rate |
10 kBit/s, 20 kBit/s, 50 kBit/s, 100 kBit/s, 125 kBit/s, 250 kBit/s, 500 kBit/s, 800 kBit/s, 1 Mbit/s |
PDO Data Rate |
100 ms |
Error Control |
Heartbeat, Emergency Message |
PDO |
3 Tx PDO |
PDO Modes |
Event/Time triggered, Synch/Asynch |
SDO |
1 server |
Position Information |
Object Dictionary 0x6020 |
Termination Resistance |
Optional |
- Elevators
- Press machines
- Crane systems
- Wood processing machines
- Marble processing machines
- Storage positioning
- Dam protections
- Sluice gate control
- Air compressors
- Glass processing machines
- Lifting platforms
- Applications in medical technologies (operating table etc.)
- Forklifts
- Screw machines
- Paper machines
- Sewing machines
- Hydraulic machines
- Sheet metal machines
- Printing machines
- Horizontal control equipments
- Construction machines
- Industrial robots
- Injection machines
- X-Y axis displacement
- Liquid level measurements and position control
Benzer Ürünler
Non-contact magnetostrictive measurement Plug-in Flange Rod type body Absolute operating Operating pressure up to 350 bar Analog output options High precision up to 0.04% IP67 or IP6K9K protection class
Non-contact and magnetostrictive measuring principle; internal connection to hydraulic or pneumatic cylinders; absolute operation, that is, not to lose position information in case of power failure
Measuring Range | Output | Protection | Linearity | Datasheet |
---|---|---|---|---|
50 - 2000 mm | Analog (0.5-4.5 V, 0.25-4.75 V, 0-10 V, 4-20 mA) | IP 67 / IP 69k | ≤±0,04 %FS | ![]() |
Precise potentiometric measurement Different measuring lengths from 75 mm to 900 mm Linearity up to 0.04% <0.01 mm high resolution Motion life of up to 100 million IP55 protection class
Precise and long-lasting position measurement; measurement at very high speeds due to the narrow bearing tolerance of the spindle and the special material-coated surface
Measuring Range | Output | Protection | Linearity | Datasheet |
---|---|---|---|---|
Different measuring lengths between 75 mm and 900 mm | Analog (potentiometric) | IP 55 | ±%0,04 | ![]() |
Precise potentiometric measurement Different measuring lengths from 25 mm to 150 mm Superior linearity up to 0.075% Motion life of up to 100 million Cable or socket version IP40 protection class
Precise and cost-effective position measurement; compact design; high speed operation; High repeatability value: 0.002 mm
Measuring Range | Output | Protection | Linearity | Datasheet |
---|---|---|---|---|
Different measuring lengths between 25mm and 150 mm | Analog (potentiometric) | IP 40 | ±%0,075 | ![]() |
Magnetic measurement Incremental encoder output Contactless / non-friction system Extra slim profile structure Measuring up to 20 meters Resolution options starting from 1µm IP67 protection class
High accuracy measurement with contactless magnetic system; Extra slim, retention profile closed system; Sealed protection against harsh environments with dust, humid and oil
Measuring Range | Output | Protection | Magnetic Tape | Resolution | Datasheet |
---|---|---|---|---|---|
Up to 20 meters | Push-Pull, TTL RS422 Line Driver | IP 67 | B2 | 1µm, 5µm, 10µm, 25 µm, 50µm, 62.5µm, 80µm, optional other resolutions | ![]() |
Magnetic measurement Incremental encoder output Contactless / non-friction system Slim profile structure Measuring up to 20 meters Resolution options starting from 5µm IP67 protection class
High accuracy measurement with contactless magnetic system; Slim, retention profile closed system; Sealed protection against harsh environments with dust, humid and oil
Measuring Range | Output | Protection | Magnetic Tape | Resolution | Datasheet |
---|---|---|---|---|---|
Up to 20 meters | Push-Pull, TTL RS422 Line Driver | IP 67 | B5 | 5µm, 10µm, 25µm, 50µm, 62.5µm, 100µm, optional other resolutions | ![]() |
Magnetic measurement Small size Easy mounting Measure up to 100 meters Resolution from 1 μm to 100 μm Model with cable or socket Spiral or PUR cable option IP67 protection class
Reader sensor for contactless measurement on magnetic tape; internal tape slider against dust; extra durability against environmental factors such as moisture, oil, dust; model with cable or socket
Measuring Range | Output | Protection | Magnetic Tape | Resolution | Datasheet |
---|---|---|---|---|---|
Up to 100 meters | Push-Pull, TTL RS422 Line Driver | IP 67 | B2, B5 | 1µm, 5 µm, 10µm, 25µm, 62.5µm, 80µm, 100µm, others on request | ![]() |